Antoine Deliniere

Dr. Antoine Deliniere


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in JAMA Cardiology
Verified
Journal Article
Open access
PDF file
FBFrancis Bessière
Francis Bessière
HRHugo Roccia
Hugo Roccia
ADAntoine Deliniere
Antoine Deliniere
RCRome Charrière
Rome Charrière
PCPhilippe Chevalier
Philippe Chevalier
MCMartin Cour
Martin Cour
The novel coronavirus disease 2019 (COVID-19) outbreak is an ongoing situation caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).1 Studies in patients with mild to moderate COVID-19 symptoms have suggested benefits of hydroxychloroquine alone or in combination with azithromycin against SARS-CoV-2 and raised hope for treating the disease.2 As a result, these treatments are increasingly used off-label for patients with COVID-19, including for those in intensive care units (ICUs).2,3 However, both medications are known to induce QT prolongation via a human Ether-à-go-go–related gene potassium channel blockade, which can promote life-threatening ventricular arrhythmias.4,5 Safety data for these treatments are largely lacking for patients with COVID-19. This is even more relevant for critically ill patients who are particularly exposed to electrolyte imbalance and/or drugs leading to an increased risk of QT prolongation.6 Therefore, we aimed to examine the safety of hydroxychloroquine with or without azithromycin regarding QT interval in ICU patients with COVID-19.

29 June 2022 in European Heart Journal
Verified
Journal Article
Open access
PDF file
PJPaloma Jorda
Paloma Jorda
LBLaurens P Bosman
Laurens P Bosman
AGAlessio Gasperetti
Alessio Gasperetti
AMAndrea Mazzanti
Andrea Mazzanti
JGJean Baptiste Gourraud
Jean Baptiste Gourraud
JCJulia Cadrin-Tourigny
Julia Cadrin-Tourigny
Aims: Arrhythmogenic right ventricular cardiomyopathy (ARVC) causes ventricular arrhythmias (VAs) and sudden cardiac death (SCD). In 2019, a risk prediction model that estimates the 5-year risk of incident VAs in ARVC was developed (ARVCrisk.com). This study aimed to externally validate this prediction model in a large international multicentre cohort and to compare its performance with the risk factor approach recommended for implantable cardioverter-defibrillator (ICD) use by published guidelines and expert consensus. Methods and results: In a retrospective cohort of 429 individuals from 29 centres in North America and Europe, 103 (24%) experienced sustained VA during a median follow-up of 5.02 (2.05–7.90) years following diagnosis of ARVC. External validation yielded good discrimination [C-index of 0.70 (95% confidence interval-CI 0.65–0.75)] and calibration slope of 1.01 (95% CI 0.99–1.03). Compared with the three published consensus-based decision algorithms for ICD use in ARVC (Heart Rhythm Society consensus on arrhythmogenic cardiomyopathy, International Task Force consensus statement on the treatment of ARVC, and American Heart Association guidelines for VA and SCD), the risk calculator performed better with a superior net clinical benefit below risk threshold of 35%. Conclusion: Using a large independent cohort of patients, this study shows that the ARVC risk model provides good prognostic information and outperforms other published decision algorithms for ICD use. These findings support the use of the model to facilitate shared decision making regarding ICD implantation in the primary prevention of SCD in ARVC.

1 February 2021 in Heart Rhythm
Verified
Journal Article
Closed access
AGAlessio Gasperetti
Alessio Gasperetti
VRValentina A. Rossi
Valentina A. Rossi
ACAlessandra Chiodini
Alessandra Chiodini
MCMichela Casella
Michela Casella
SCSarah Costa
Sarah Costa
ASArdan M. Saguner
Ardan M. Saguner

15 September 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
GDGeoffroy Ditac
Geoffroy Ditac
PCPierre-Jean COTTINET
Pierre-Jean COTTINET
MLMinh-Quyen LE
Minh-Quyen LE
DGDaniel Grinberg
Daniel Grinberg
JDJosselin Duchateau
Josselin Duchateau
FBFrancis Bessière
Francis Bessière
Climate change represents the biggest global health threat of the 21st century. Health care system is itself a large contributor to greenhouse gas (GHG) emissions. In cardiology, atrial fibrillation (AF) catheter ablation is an increasing activity using numerous non-reusable materials that could contribute to GHG emission. Determining a detailed carbon footprint analysis of an AF catheter ablation procedure allows the identification of the main polluting sources that give opportunities for reduction of environmental impact. To assess the carbon footprint of AF catheter ablation procedure. To determine priority actions to decrease pollution. An eco-audit method used to predict the GHG emission of an AF catheter ablation procedure was investigated. Two workstations were considered including surgery and anaesthesia. In the operating room, every waste produced by single-use medical devices, pharmaceutical drugs, and energy consumption during intervention were evaluated. All analyses were limited to the operating room. Thirty procedures were analysed over a period of 8 weeks: 18 pulmonary veins isolation RF ablations, 7 complex RF procedures including PVI, roof and mitral isthmus lines, ethanol infusion of the Marshall vein and cavo tricuspid isthmus line, and 5 pulmonary vein isolation with cryoballoon. The mean emission during AF catheter ablation procedures was 76.9 kg of carbon dioxide equivalent (CO2-e). The operating field accounted for 75.4% of the carbon footprint, while only 24.6% for the anaesthesia workstation. On one hand, material production and manufacturing were the most polluting phases of product life cycle which, respectively, represented 71.3% (54.8 kg of CO2-e) and 17.0% (13.1 kg of CO2-e) of total pollution. On the other hand, transport contributed in 10.6% (8.1 kg of CO2-e), while product use resulted in 1.1% (0.9 kg of CO2-e) of GHG production. Electrophysiology catheters were demonstrated to be the main contributors of environmental impact with 29.9 kg of CO2-e (i.e. 38.8%). Three dimensional mapping system and electrocardiogram patches were accounting for 6.8 kg of CO2-e (i.e. 8.8% of total). AF catheter ablation involves a mean of 76.9 kg of CO2-e. With an estimated 600 000 annual worldwide procedures, the environmental impact of AF catheter ablation activity is estimated equal to 125 tons of CO2 emission each day. It represents an equivalent of 700 000 km of car ride every day. Electrophysiology catheters and patches are the main contributors of the carbon footprint. The focus must be on reducing, reusing, and recycling these items to limit the impact of AF ablation on the environment. A road map of steps to implement in different time frames is proposed.

9 June 2019 in EP Europace
Verified
Journal Article
Closed access
ADAntoine Deliniere
Antoine Deliniere
ABAdrian Baranchuk
Adrian Baranchuk
JGJoris Giai
Joris Giai
FBFrancis Bessiere
Francis Bessiere
DMDelphine Maucort-Boulch
Delphine Maucort-Boulch
PCPhilippe Chevalier
Philippe Chevalier
Aims: There is currently no reliable tool to quantify the risks of ventricular fibrillation or sudden cardiac arrest (VF/SCA) in patients with spontaneous Brugada type 1 pattern (BrT1). Previous studies showed that electrocardiographic (ECG) markers of depolarization or repolarization disorders might indicate elevated risk. We aimed to design a VF/SCA risk prediction model based on ECG analyses for adult patients with spontaneous BrT1. Methods and results: This retrospective multicentre international study analysed ECG data from 115 patients (mean age 45.1 ± 12.8 years, 105 males) with spontaneous BrT1. Of these, 45 patients had experienced VF/SCA and 70 patients did not experience VF/SCA. Among 10 ECG markers, a univariate analysis showed significant associations between VF/SCA and maximum corrected Tpeak–Tend intervals ≥100 ms in precordial leads (LMaxTpec) (P < 0.001), BrT1 in a peripheral lead (pT1) (P = 0.004), early repolarization in inferolateral leads (ER) (P < 0.001), and QRS duration ≥120 ms in lead V2 (P = 0.002). The Cox multivariate analysis revealed four predictors of VF/SCA: the LMaxTpec [hazard ratio (HR) 8.3, 95% confidence interval (CI) 2.4–28.5; P < 0.001], LMaxTpec + ER (HR 14.9, 95% CI 4.2–53.1; P < 0.001), LMaxTpec + pT1 (HR 17.2, 95% CI 4.1–72; P < 0.001), and LMaxTpec + pT1 + ER (HR 23.5, 95% CI 6–93; P < 0.001). Our multidimensional penalized spline model predicted the 1-year risk of VF/SCA, based on age and these markers. Conclusion: LMaxTpec and its association with pT1 and/or ER indicated elevated VF/SCA risk in adult patients with spontaneous BrT1. We successfully developed a simple risk prediction model based on age and these ECG markers.

9 January 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
RCRichard T Carrick
Richard T Carrick
CMCorrado De Marco
Corrado De Marco
AGAlessio Gasperetti
Alessio Gasperetti
LBLaurens P Bosman
Laurens P Bosman
JGJean-Baptiste Gourraud
Jean-Baptiste Gourraud
JCJulia Cadrin-Tourigny
Julia Cadrin-Tourigny
Background and Aims: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. Methods: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. Results: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. Conclusions: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.