Xiang JI

Dr. Xiang JI

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2015 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
SSShiteng Suo
Shiteng Suo
KZKebei Zhang
Kebei Zhang
MCMengqiu Cao
Mengqiu Cao
XSXinjun Suo
Xinjun Suo
JHJia Hua
Jia Hua
JXJianrong Xu
Jianrong Xu
Purpose To investigate the utility of whole-lesion apparent diffusion coefficient (ADC) histogram analysis in capturing breast lesion heterogeneity and determine which ADC metric may help best differentiate benign from malignant breast mass lesions at 3.0T magnetic resonance imaging (MRI). Materials and Methods We retrospectively included 101 women with breast mass lesions (benign:malignant = 36:65) who underwent 3.0T diffusion-weighted imaging (DWI) and subsequently had histopathologic confirmation. ADC histogram parameters, including the mean, minimum, maximum, 10th/25th/50th/75th/90th percentile, skewness, kurtosis, and entropy ADCs, were derived for the whole-lesion volume in each patient. Mann–Whitney U-test, univariate and multivariate logistic regression, area under the receiver-operating characteristic curve (Az), intraclass correlation coefficient (ICC), and Bland–Altman test were used for statistical analysis. Results Mean, minimum, maximum, and 10th/25th/50th/75th/90th percentile ADCs were significantly lower (all P < 0.0001), while skewness and entropy ADCs were significantly higher (P < 0.001 and P = 0.001, respectively) in malignant lesions compared with benign ones. The Az values of minimum and 25th percentile ADCs were significantly higher than that of mean ADC (P = 0.0194 and P = 0.0154, respectively) or that of median ADC (P = 0.0300 and P = 0.0401, respectively), indicating that minimum and 25th percentile ADCs may be more accurate for lesion discrimination. Multivariate logistic regression showed that the minimum ADC was the unique independent predictor of breast malignancy. Minimum and 25th percentile ADCs had excellent interobserver agreement (ICC = 0.943 and 0.989, respectively; narrow width of 95% limits of agreement). Conclusion These results suggest that whole-lesion ADC histogram analysis may facilitate the differentiation between benign and malignant breast mass lesions. J. Magn. Reson. Imaging 2016;43:894–902

1 January 2015 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
SSShiteng Suo
Shiteng Suo
XCXiaoxi Chen
Xiaoxi Chen
XJXiang JI
Xiang JI
ZZZhiguo Zhuang
Zhiguo Zhuang
LWLianming Wu
Lianming Wu
JXJianrong Xu
Jianrong Xu
The objective of this study was to investigate the non-Gaussian water diffusion properties in bladder cancer and assess the efficacy of diffusion kurtosis imaging for estimating the histological grade of bladder cancer.Twenty-one patients with bladder cancer (high-grade, 12; low-grade, 9) and 17 negative controls who underwent preoperative 3.0-T magnetic resonance imaging including multi-b value diffusion-weighted imaging (b values, 0, 500, 800, 1200, 1500, and 2000 s/mm) were included. Besides apparent diffusion coefficient (ADC) maps, diffusion kurtosis imaging maps for diffusion coefficient (Dapp) and kurtosis (Kapp) were also obtained. Data were analyzed using the Mann-Whitney U test, Spearman correlation test, and receiver operating characteristic curves.Bladder cancer showed significantly lower ADC values, lower Dapp values, and higher Kapp values compared with normal bladder wall (all P < 0.001). The Kapp values were significantly higher in high-grade than in low-grade tumors (P = 0.007). Significant correlations were found between Dapp and ADC (r = 0.901, P < 0001) as well as between Kapp and ADC (r = -0.910, P <0.001). The areas under the receiver operating characteristic curve were 0.843 and 0.796 for estimation of high-grade bladder cancer by using the Kapp values and ADC values, respectively.Diffusion in bladder cancer follows a non-Gaussian behavior. The new metric Kapp may potentially serve as a biomarker of grade of bladder cancer.

23 February 2024 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
PWPengcheng Wang
Pengcheng Wang
CTChunjie Tan
Chunjie Tan
XJXiang JI
Xiang JI
JBJingfeng Bai
Jingfeng Bai
AYAlfred C.H. Yu
Alfred C.H. Yu
PQPeng Qin
Peng Qin
The use of the subharmonic signal from microbubbles exposed to ultrasound is a promising safe and cost-effective approach for the non-invasive measurement of blood pressure. Achieving a high sensitivity of the subharmonic amplitude to the ambient overpressure is crucial for clinical applications. However, currently used microbubbles have a wide size distribution and diverse shell properties. This causes uncertainty in the response of the subharmonic amplitude to changes in ambient pressure, which limits the sensitivity. The aim of this study was to use monodisperse microbubbles to improve the sensitivity of subharmonic-based pressure measurements. With the same shell materials and gas core, we used a flow-focusing microfluidic chip and a mechanical agitation method to fabricate monodisperse (∼2.45-µm mean radius and 4.7 % polydisperse index) and polydisperse microbubbles (∼1.51-µm mean radius and 48.4 % polydisperse index), respectively. We varied the ultrasound parameters (i.e., the frequency, peak negative pressure (PNP) and pulse length), and found that there was an optimal excitation frequency (2.8 MHz) for achieving maximal subharmonic emission for monodisperse microbubbles, but not for polydisperse microbubbles. Three distinct regimes (occurrence, growth, and saturation) were identified in the response of the subharmonic amplitude to increasing PNP for both monodisperse and polydisperse microbubbles. For the polydisperse microbubbles, the subharmonic amplitude decreased either monotonically or non-monotonically with ambient overpressure, depending on the PNP. By contrast, for the monodisperse microbubbles, there was only a monotonic decrease at all PNPs. The maximum sensitivity (1.18 dB/kPa, R2 = 0.97) of the subharmonic amplitude to ambient overpressure for the monodisperse microbubbles was ∼6.5 times higher than that for the polydisperse microbubbles (0.18 dB/kPa, R2 = 0.88). These results show that monodisperse microbubbles can achieve a more consistent response of the subharmonic signal to changes in ambient overpressure and greatly improve the measurement sensitivity.

30 August 2009 in Journal of Zhejiang University-SCIENCE B
Verified
Journal Article
Closed access
PDF file
XJXiang JI
Xiang JI
JBJing-Feng Bai
Jing-Feng Bai
GSGuofeng Shen
Guofeng Shen
YCYa-Zhu Chen
Ya-Zhu Chen
Under some circumstances surgical resection is feasible in a low percentage for the treatment of deep tumors. Nevertheless, high-intensity focused ultrasound (HIFU) is beginning to offer a potential noninvasive alternative to conventional therapies for the treatment of deep tumors. In our previous study, a large scale spherical HIFU-phased array was developed to ablate deep tumors. In the current study, taking into account the required focal depth and maximum acoustic power output, 90 identical circular PZT-8 elements (diameter=1.4 cm and frequency=1 MHz) were mounted on a spherical shell with a radius of curvature of 18 cm and a diameter of 21 cm. With the developed array, computer simulations and ex vivo experiments were carried out. The simulation results theoretically demonstrate the ability of the array to focus and steer in the specified volume (a 2 cm×2 cm×3 cm volume) at the focal depth of 15 to 18 cm. Ex vivo experiment results also verify the capability of the developed array to ablate deep target tissue by either moving single focal point or generating multiple foci simultaneously.

1 December 2018 in Applied Acoustics
Verified
Journal Article
Closed access
KLKe Li
Ke Li
JBJingfeng Bai
Jingfeng Bai
YCYazhu Chen
Yazhu Chen
XJXiang JI
Xiang JI

1 May 2012 in Applied Acoustics
Verified
Journal Article
Closed access
XJXiang JI
Xiang JI
GSGuofeng Shen
Guofeng Shen
JBJingfeng Bai
Jingfeng Bai
YCYazhu Chen
Yazhu Chen