Guofeng Shen

Dr. Guofeng Shen


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2009 in Journal of Zhejiang University-SCIENCE B
Verified
Journal Article
Closed access
PDF file
XJXiang JI
Xiang JI
JBJing-Feng Bai
Jing-Feng Bai
GSGuofeng Shen
Guofeng Shen
YCYa-Zhu Chen
Ya-Zhu Chen
Under some circumstances surgical resection is feasible in a low percentage for the treatment of deep tumors. Nevertheless, high-intensity focused ultrasound (HIFU) is beginning to offer a potential noninvasive alternative to conventional therapies for the treatment of deep tumors. In our previous study, a large scale spherical HIFU-phased array was developed to ablate deep tumors. In the current study, taking into account the required focal depth and maximum acoustic power output, 90 identical circular PZT-8 elements (diameter=1.4 cm and frequency=1 MHz) were mounted on a spherical shell with a radius of curvature of 18 cm and a diameter of 21 cm. With the developed array, computer simulations and ex vivo experiments were carried out. The simulation results theoretically demonstrate the ability of the array to focus and steer in the specified volume (a 2 cm×2 cm×3 cm volume) at the focal depth of 15 to 18 cm. Ex vivo experiment results also verify the capability of the developed array to ablate deep target tissue by either moving single focal point or generating multiple foci simultaneously.

3 July 2024 in Neuroscience
Verified
Journal Article
Closed access
JXJiapei Xie
Jiapei Xie
WZWeidong Zhang
Weidong Zhang
CYChen Yu
Chen Yu
WWWei Wei
Wei Wei
YBYan Bai
Yan Bai
MWMeiyun Wang
Meiyun Wang

1 November 2013 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
YYYing Yu
Ying Yu
GSGuofeng Shen
Guofeng Shen
Yufeng ZhouYufeng Zhou
Yufeng Zhou
JBJingfeng Bai
Jingfeng Bai
YCYazhu Chen
Yazhu Chen

6 April 2010 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
DLDehui Li
Dehui Li
GSGuofeng Shen
Guofeng Shen
HLHui Luo
Hui Luo
JBJinfeng Bai
Jinfeng Bai
YCYazhu Chen
Yazhu Chen

27 January 2011 in Journal of Shanghai Jiaotong University (Science)
Verified
Journal Article
Closed access
PDF file
XJXiang JI
Xiang JI
GSGuofeng Shen
Guofeng Shen
JBJing-Feng Bai
Jing-Feng Bai
DLDe-Hui Li
De-Hui Li
YYYing Yu
Ying Yu
YCYa-Zhu Chen
Ya-Zhu Chen

1 December 2023 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PXPeng Xu
Peng Xu
NWNan Wu
Nan Wu
GSGuofeng Shen
Guofeng Shen
Transcranial focused ultrasound ablation has emerged as a promising technique for treating neurological disorders. The clinical system exclusively employed the ray tracing method to compute phase aberrations induced by the human skull, taking into account computational time constraints. However, this method compromises slightly on accuracy compared to simulation-based methods. This study evaluates a fast simulation method that simulates the time-harmonic pressure field within the region of interest for effective phase correction. Experimental validation was carried out using a 512-element, 670 kHz hemispherical transducer for four ex vivo skulls. The ray tracing method achieved a restoration ratio of 64.81% ± 4.33% of acoustic intensity normalized to hydrophone measurements. In comparison, the rapid simulation method demonstrated improved results with a restoration ratio of 73.10% ± 7.46%, albeit slightly lower than the full-wave simulation which achieved a restoration ratio of 75.87% ± 5.40%. The rapid simulation methods exhibited computational times that were less than five minutes for parallel computation with 8 threads. The incident angle was calculated, and a maximum difference of 6.8 degrees was found when the fixed position of the skull was changed. Meanwhile, the restoration ratio of acoustic intensity was validated to be above 70% for different target positions away from the geometrical focus of the transducer. The favorable balance between time consumption and correction accuracy makes this method valuable for clinical treatment applications.