Spiros Zinelis

Prof. Spiros Zinelis

National and Kapodistrian University of Athens, Athens, Greece
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2015 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
TKTheodoros Koutsoukis
Theodoros Koutsoukis
Spiros ZinelisSpiros Zinelis
Spiros Zinelis
GEGeorge Eliades
George Eliades
KAKhalid Al‐Wazzan
Khalid Al‐Wazzan
MRMohammed Al Rifaiy
Mohammed Al Rifaiy
YJYoussef Al Jabbari
Youssef Al Jabbari

1 December 2004 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
SSSusan Schuster
Susan Schuster
GEGeorge Eliades
George Eliades
Spiros ZinelisSpiros Zinelis
Spiros Zinelis
Theodore EliadesTheodore Eliades
Theodore Eliades
TBT. Gerard Bradley
T. Gerard Bradley

1 April 2014 in Dental Materials
Verified
Journal Article
Closed access
YJYoussef Al Jabbari
Youssef Al Jabbari
TKT. Koutsoukis
T. Koutsoukis
XBX. Barmpagadaki
X. Barmpagadaki
Spiros ZinelisSpiros Zinelis
Spiros Zinelis

28 July 2019 in Materials
Verified
Journal Article
Open access
PDF file
APAlexandra K. Papadopoulou
Alexandra K. Papadopoulou
ACAurélie Cantele
Aurélie Cantele
GPGeorgios Polychronis
Georgios Polychronis
Spiros ZinelisSpiros Zinelis
Spiros Zinelis
Theodore EliadesTheodore Eliades
Theodore Eliades
The aim of this study was to estimate the possible changes of surface roughness and the mechanical properties of Invisalign® appliances over one- and two-week of service. Forty appliances with attachments were retrieved after the end of orthodontic treatment from different patients. Half of them had been used for one week (1W), and the rest for two weeks (2W). Ten unused Invisalign® appliances were used as the control (CON). An equal number of teeth possessing attachments were cut of aligners deriving from all groups (1W, 2W, and CON), and the Sa, Sq, Sz, Sc, and Sv roughness parameters of the internal surface of the aligner attachment area and the opposite lingual side (which was in contact to enamel) were determined by optical profilometry. Then, ten first molars originating from all groups were embedded in acrylic resin, and were ground and polished. Instrumented indentation testing (IIT) was performed in order to determine the Martens hardness (HM), indentation modulus (EIT), and relaxation index (RIT), according to ISO 14577-2002. The produced data were statistically processed by one- or two-way analysis of variance (ANOVA) and multiple comparison post-hoc tests (a = 0.05). Both the surface roughness and mechanical properties of the retrieved groups (1W and 2W) showed statistically significant differences compared with CON, but without statistically significant differences between each other. The roughness variables of the as-received material were shown to be reduced after intraoral service demonstrating a wear effect. Ageing has a detrimental effect on the surface roughness and mechanical properties of Invisalign® appliances, although this effect is restricted to the first week of clinical usage.

1 April 2009 in Dental Materials
Verified
Journal Article
Closed access
ULUlrich Lohbauer
Ulrich Lohbauer
Spiros ZinelisSpiros Zinelis
Spiros Zinelis
Christos RahiotisChristos Rahiotis
Christos Rahiotis
APAnselm Petschelt
Anselm Petschelt
GEGeorge Eliades
George Eliades

4 October 2021 in Orthodontics & Craniofacial Research
Verified
Journal Article
Open access
PDF file
Spiros ZinelisSpiros Zinelis
Spiros Zinelis
NEARCHOS PANAYINEARCHOS PANAYI
NEARCHOS PANAYI
GPGeorgios Polychronis
Georgios Polychronis
Spyridon N. PapageorgiouSpyridon N. Papageorgiou
Spyridon N. Papageorgiou
Theodore EliadesTheodore Eliades
Theodore Eliades
Objective: The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices.Materials and Methods: Five 3D printers (Ka:rv LP 550, Swinwon; “KAR”), (L120, Dazz 3D; “L12”), (MiiCraft 125, Miicraft Jena; “MIC”), (Slash 2, Uniz; “SLS”) and (Pro 95, SprintRay; “PRO”) were used to prepare orthodontic aligners with dental resin (Tera Harz TC‐85DAW, Graphy). The central incisors of each aligner were cut, prepared and evaluated in terms of Martens‐Hardness (HM), indentation‐modulus (EIT) and elastic‐index (ηIT) as per ISO14577‐1:2002. Force‐indentation curves were recorded and differences among printers were checked with generalized linear regressions (alpha=5%).Results: Statistically significant differences were seen for all mechanical properties (P < .05), which were in descending order: HM (N/mm2) as median (Interquartile Range [IQR]): SLS 108.5 (106.0‐112.0), L12 103.0 (102.0‐107.0), KAR 101.5 (97.5‐103.0), MIC 100.0 (97.5‐101.5) and PRO 94.0 (93.0‐96.0); EIT (MPa) as mean (Standard Deviation [SD]): SLS 2696.3 (124.7), L12 2627.8 (73.5), MIC 2566.2 (125.1), KAR 2565.0 (130.2) and PRO 2491.2 (53.3); and ηIT (%) as median (IQR): SLS 32.8 (32.3‐33.1), L12 31.6 (30.8‐32.3), KAR 31.3 (30.9‐31.9), MIC 30.5 (29.9‐31.2) and PRO 29.5 (29.1‐30.0). Additionally, significant differences existed between liquid crystal display (LCD) and digital light processing (DLP) printers for HM (P < .001), EIT (P = .002) and ηIT (P < .001), with aligners from the former having higher values than aligners from the latter printer.Conclusion: Under the limitations of this study, it may be concluded that the mechanical properties of 3D‐printed orthodontic aligners are dependent on the 3D printer used, and thus, differences in their clinical efficacy are anticipated.