The aim of this study was to estimate the possible changes of surface roughness and the mechanical properties of Invisalign® appliances over one- and two-week of service. Forty appliances with attachments were retrieved after the end of orthodontic treatment from different patients. Half of them had been used for one week (1W), and the rest for two weeks (2W). Ten unused Invisalign® appliances were used as the control (CON). An equal number of teeth possessing attachments were cut of aligners deriving from all groups (1W, 2W, and CON), and the Sa, Sq, Sz, Sc, and Sv roughness parameters of the internal surface of the aligner attachment area and the opposite lingual side (which was in contact to enamel) were determined by optical profilometry. Then, ten first molars originating from all groups were embedded in acrylic resin, and were ground and polished. Instrumented indentation testing (IIT) was performed in order to determine the Martens hardness (HM), indentation modulus (EIT), and relaxation index (RIT), according to ISO 14577-2002. The produced data were statistically processed by one- or two-way analysis of variance (ANOVA) and multiple comparison post-hoc tests (a = 0.05). Both the surface roughness and mechanical properties of the retrieved groups (1W and 2W) showed statistically significant differences compared with CON, but without statistically significant differences between each other. The roughness variables of the as-received material were shown to be reduced after intraoral service demonstrating a wear effect. Ageing has a detrimental effect on the surface roughness and mechanical properties of Invisalign® appliances, although this effect is restricted to the first week of clinical usage.
1 March 2016 in Journal of Oral and Maxillofacial Surgery
Although Rapid Maxillary Expansion (RME) has been used for over a century, its effect on upper airways has not yet adequately been assessed in an evidence-based manner. To investigate the volumetric changes in the upper airway spaces following RME in growing subjects by means of acoustic rhinometry, three-dimensional radiography and digital photogrammetry. Literature search of electronic databases and additional manual searches up to February 2016. Randomized clinical trials, prospective or retrospective controlled clinical trials and cohort clinical studies of at least eight patients, where the RME appliance was left in place for retention, and a maximum follow-up of 8 months post-expansion. After duplicate data extraction and assessment of the risk of bias, the mean differences and 95 per cent confidence intervals (CIs) of upper airway volume changes were calculated with random-effects meta-analyses, followed by subgroup analyses, meta-regressions, and sensitivity analyses. Twenty studies were eligible for qualitative synthesis, of which 17 (3 controlled clinical studies and 14 cohort studies) were used in quantitative analysis. As far as total airway volume is concerned patients treated with RME showed a significant increase post-expansion (5 studies; increase from baseline: 1218.3mm3; 95 per cent CI: 702.0 to 1734.6mm3), which did not seem to considerably diminish after the retention period (11 studies; increase from baseline: 1143.9mm3; 95 per cent CI: 696.9 to 1590.9mm3). However, the overall quality of evidence was judged as very low, due to methodological limitations of the included studies, absence of untreated control groups, and inconsistency among studies. RME seems to be associated with an increase in the nasal cavity volume in the short and in the long term. However, additional well-conducted prospective controlled clinical studies are needed to confirm the present findings. None. Australian Society of Orthodontics Foundation for Research and Education Inc.
1 April 2020 in American Journal of Orthodontics and Dentofacial Orthopedics