Shinya Kowase

Dr. Shinya Kowase

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2021 in European Heart Journal
Verified
Journal Article
Open access
PDF file
TITaisuke Ishikawa
Taisuke Ishikawa
HKHiroki Kimoto
Hiroki Kimoto
HMHiroyuki Mishima
Hiroyuki Mishima
KYKenichiro Yamagata
Kenichiro Yamagata
SOSoshiro Ogata
Soshiro Ogata
NMNaomasa Makita
Naomasa Makita
The prognostic value of genetic variants for predicting lethal arrhythmic events (LAEs) in Brugada syndrome (BrS) remains controversial. We investigated whether the functional curation of SCN5A variations improves prognostic predictability. Using a heterologous expression system and whole-cell patch clamping, we functionally characterized 22 variants of unknown significance (VUSs) among 55 SCN5A mutations previously curated using in silico prediction algorithms in the Japanese BrS registry (n = 415). According to the loss-of-function (LOF) properties, SCN5A mutation carriers (n = 60) were divided into two groups: LOF-SCN5A mutations and non-LOF SCN5A variations. Functionally proven LOF-SCN5A mutation carriers (n = 45) showed significantly severer electrocardiographic conduction abnormalities and worse prognosis associated with earlier manifestations of LAEs (7.9%/year) than in silico algorithm-predicted SCN5A carriers (5.1%/year) or all BrS probands (2.5%/year). Notably, non-LOF SCN5A variation carriers (n = 15) exhibited no LAEs during the follow-up period. Multivariate analysis demonstrated that only LOF-SCN5A mutations and a history of aborted cardiac arrest were significant predictors of LAEs. Gene-based association studies using whole-exome sequencing data on another independent SCN5A mutation-negative BrS cohort (n = 288) showed no significant enrichment of rare variants in 16 985 genes including 22 non-SCN5A BrS-associated genes as compared with controls (n = 372). Furthermore, rare variations of non-SCN5A BrS-associated genes did not affect LAE-free survival curves. In vitro functional validation is key to classifying the pathogenicity of SCN5A VUSs and for risk stratification of genetic predictors of LAEs. Functionally proven LOF-SCN5A mutations are genetic burdens of sudden death in BrS, but evidence for other BrS-associated genes is elusive. Among currently recognized genetic and non-genetic risk factors for Brugada syndrome, functionally validated loss-of-function SCN5A mutations are associated with worse prognosis with earlier manifestation of lethal arrhythmic events (7.9%/year) than in silico algorithm-predicted SCN5A rare variations (5.1%/year) or Brugada-type ECG (2.5%/year).

1 September 2016 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
KMKeita Masuda
Keita Masuda
ANAkihiko Nogami
Akihiko Nogami
KKKenji Kuroki
Kenji Kuroki
MIMiyako Igarashi
Miyako Igarashi
YSYukio Sekiguchi
Yukio Sekiguchi
KAKazutaka Aonuma
Kazutaka Aonuma
Background—: Catheter ablation is an effective therapy for ventricular fibrillation (VF) arising from the Purkinje system in ischemic heart disease. However, some patients experience newly emergent monomorphic ventricular tachycardia (VT) after the ablation of VF. We evaluated the prevalence and mechanism of monomorphic VT after VF ablation. Methods and Results—: Twenty-one consecutive patients with primary VF because of ischemic heart disease who underwent catheter ablation were retrospectively analyzed. Twenty of 21 patients were in electrical storm. Ventricular premature contractions triggering VF arose from the left Purkinje system and were targeted for ablation. Before the ablation, 14 of 21 patients had only VF, and the other 7 had VF and concomitant monomorphic VT. Four of the 14 patients with only VF (29%) exhibited newly emergent monomorphic VT after VF ablation. Three of these patients had Purkinje-related VTs, which were successfully eliminated by the ablation of a Purkinje network located in the same low-voltage area as the site of prior successful VF ablation. During a median follow-up of 28 months (interquartile range, 16–68 months), VF recurred in 6 of 21 patients (29%); however, there were neither electrical storms nor monomorphic VT, and all recurring arrhythmias were controlled by medical therapy alone. Conclusions—: Over one fifth of patients with primary ischemic VF experienced newly emergent Purkinje-related monomorphic VT after VF ablation. The circuit of the monomorphic VT associated with the Purkinje network was located in the same low-voltage area as the Purkinje tissue that triggered VF and could be suppressed by additional ablation.

1 December 2025 in EP Europace
Verified
Journal Article
Open access
THTatsuya Hayashi
Tatsuya Hayashi
YKYuki Komatsu
Yuki Komatsu
SKShinya Kowase
Shinya Kowase
SFSeiji Fukamizu
Seiji Fukamizu
KNKoichi Nagashima
Koichi Nagashima
HFHideo Fujita
Hideo Fujita
Aims: Catheter ablation for premature ventricular contractions (PVCs) triggering ventricular fibrillation (VF) after acute myocardial infarction (AMI) has proven effective, with Purkinje potentials often serving as the target. However, the electrophysiological features of Purkinje potentials and their relationship with the conduction system in VF-triggering PVCs remain unclear. Methods: This multicentre retrospective study analysed patients who underwent catheter ablation for VF-triggering PVCs during the acute or subacute phase of AMI. Characteristics of Purkinje potentials, including retrograde conduction from the Purkinje network and subsequent anterograde conduction to the right bundle branch (RB), were evaluated for PVC morphology. Results: Fifty-three patients (mean age 66±11 years; 13% female) with 67 VF-triggering PVCs were analysed. The mean PVC width was 157 ± 42 ms, with 87% showing RB branch block morphology. Purkinje potentials preceded 72% of PVCs (mean interval 68 ± 42 ms). PVCs with preceding Purkinje potentials had narrower QRS duration (145 ± 26 ms vs. 198 ± 57 ms, P < 0.0001). The coupling interval from the preceding sinus beat was inversely correlated with the interval from Purkinje potential to PVC onset (P < 0.0001). Retrograde Purkinje conduction with subsequent anterograde RB conduction was identified in 9%. In these cases, the coupling interval from the preceding sinus beat was longer (391 ± 12 ms vs. 467 ± 34 ms, P = 0.041). Conclusion: Purkinje potentials show distinct properties that influence both QRS duration and PVC timing. The presence of preceding Purkinje potentials together with QRS duration may help guide ablation strategies. In rare cases, Purkinje activity conducts retrogradely from the left bundle and anterogradely through the RB, modifying PVC morphology.

31 December 2021 in HeartRhythm Case Reports
Verified
Journal Article
Open access
HHHaruka Hondo
Haruka Hondo
SKShinya Kowase
Shinya Kowase
SAShunichi Asano
Shunichi Asano
JOJun Osada
Jun Osada
HAHajime Aoki
Hajime Aoki
KYKazuhiko Yumoto
Kazuhiko Yumoto

7 October 2022 in Journal of Arrhythmia
Verified
Journal Article
Open access
SIShota Ikeda
Shota Ikeda
KSKazuo Sakamoto
Kazuo Sakamoto
DTDaigo Tokudome
Daigo Tokudome
SKShunsuke Kawai
Shunsuke Kawai
KOKiyohiro Ogawa
Kiyohiro Ogawa
HTHiroyuki Tsutsui
Hiroyuki Tsutsui
Background: Focal Purkinje ventricular arrhythmias (VAs) might originate from the vicinity of the proximal portion of the cardiac conducting system. This study aimed to clarify the features associated with focal Purkinje VAs originating from the proximal conduction system.Methods: A total of 18 patients with focal Purkinje VAs undergoing radiofrequency catheter ablation (RFCA) were retrospectively examined and divided into the proximal type or the non‐proximal type. The proximal type was defined as having the origin at the proximal half of the interventricular septum, or the proximal half and the septal side of the anterior wall. The 12‐lead electrocardiogram and electrophysiological findings were investigated.Results: Seven patients met criteria for proximal type of focal Purkinje VA. Out of the 7, 4 patients with proximal VAs had multiple QRS morphologies of VAs clinically, whereas out of 11 patients with non‐proximal VAs, only 1 had multiple morphologies (p = .047). VA QRS duration was shorter in the proximal type than in the non‐proximal type (111.2 ± 19.8 ms vs. 135.7 ± 17.7 ms; p = .003). The absolute axis difference between sinus rhythm and VA was smaller in the proximal type (80.4 ± 46.1°vs. 138.8 ± 59.6°; p = .014). The absolute axis difference ≤134° was useful in distinguishing the two types. Recurrence of VA was recorded in 3 proximal type patients and 3 non‐proximal type patients. No procedure‐related conduction block was observed.Conclusion: A VA of absolute axis difference ≤134°, and multiple QRS morphologies of clinical VAs indicate a proximal origin. Focal Purkinje VAs from proximal origins can be suppressed by RFCA without severe conduction disturbance.

1 July 2018 in HeartRhythm Case Reports
Verified
Journal Article
Open access
SIShota Ikeda
Shota Ikeda
KKKenji Kurosaki
Kenji Kurosaki
YKYuki Komatsu
Yuki Komatsu
SKShinya Kowase
Shinya Kowase
ANAkihiko Nogami
Akihiko Nogami