Aims: Catheter ablation (CA) of idiopathic ventricular arrhythmias (VAs) from the epicardial left ventricular summit is challenging. The endocardial approach targets two sites: the endocardial closest site (ECS) to the epicardial earliest activation site (epi-EAS) and the endocardial earliest activation site (endo-EAS). We aimed to differentiate between cases where CA at the ECS was effective and where CA at the endo-EAS yielded success. Methods and results: Fifty-eight patients (47 men; age 60 ± 13 years) were analysed with VAs in which the EAS was observed in the coronary venous system (CVS). Overall, VAs were successfully eliminated in 42 (72%) patients: 8 in the CVS, 8 where the ECS matched with the endo-EAS, 11 at the ECS, and 15 at the endo-EAS. A successful ECS ablation was associated with a shorter epi-EAS–ECS distance (10.2 ± 4.7 vs. 18.8 ± 5.3 mm; P < 0.001) and shorter epi-EAS–left main coronary trunk (LMT) ostial distance (20.3 ± 7.6 vs. 30.3 ± 8.4 mm; P = 0.005), with optimal cut-off values of ≤12.6 and ≤24.0 mm, respectively. A successful endo-EAS ablation was associated with an earlier electrogram at the endo-EAS [23 (8, 36) vs. 15 (0, 19) ms preceding the QRS; P < 0.001] and shorter epi-EAS–endo-EAS interval [6 (1, 8) vs. 22 (12, 25) ms; P < 0.001], with optimal cut-off values of ≥18 and ≤9 ms, respectively. Conclusion: Shorter anatomical distances between the epi-EAS and ECS, and between the epi-EAS and LMT ostium, predict a successful ECS ablation. The prematurity of the endo-EAS electrogram and a shorter interval between the epi-EAS and endo-EAS predicted a successful endo-EAS ablation.
In the era of cryoablation and pulsed‐field ablation, where large sheaths are commonly used, preventing air embolism is crucial. The lid from SL sheath packaging can be repurposed as a water‐seal device for catheter insertion, thereby eliminating the need for additional equipment.
The aim of this study was to identify the ECG features that might differentiate between anterior interventricular vein (AIV) and distal great cardiac vein (d-GCV) outflow tract-ventricular arrhythmias (OT-VAs). Radiofrequency catheter ablation was performed in 13 of 375 patients (3.5%) for AIV or d-GCV OT-VAs. We grouped the 13 patients by the origin, d-GCV (n=9) or AIV (n=4), and compared their ECGs and electrophysiological data. The OT-VA ECGs had S waves in lead I in all 13 patients. The voltage in the inferior lead III and peak deflection index showed no significant between-group differences (2.3±0.7 vs. 2.5±0.3 mV and 0.65±0.04 vs. 0.68±0.04 mV, respectively) for the d-GCV and AIV groups. There were also no significant between-group differences in the QaVL/QaVR, where Q denotes the amplitude of the Q wave in the suffix lead. However, the R/S ratio in V1 (1.7±1.0 [n=5] vs. 0.2±0.05, P=0.04), and QRS duration (149±16.6 vs. 123±3.8 ms, P=0.012) were greater in the d-GCG group than in the AIV group. There were no significant between-group differences in the activation time or pace mapping score at the optimal ablation sites. A low R/S ratio in V1 and shorter QRS duration may help identify AIV sites of epicardial OT-VA origin.
Background Catheter ablation for paroxysmal supraventricular tachycardia (PSVT) is an established treatment, but the effect of deep sedation on PSVT inducibility remains unclear. Aim We sought to examine PSVT inducibility and outcomes of catheter ablation under deep sedation using adaptive servo ventilation (ASV). Methods We retrospectively evaluated consecutive patients who underwent catheter ablation for PSVT under deep sedation (Propofol + Dexmedetomidine) with use of ASV. Anesthetic depth was controlled with BIS™ monitoring, and phenylephrine was administered to prevent anesthesia‐induced hypotension. PSVT induction was attempted in all patients using extrastimuli at baseline, and after isoproterenol (ISP) infusion when necessary. Results PSVT was successfully induced in 145 of 147 patients, although ISP infusion was required in the majority (89%). The PSVT was atrioventricular nodal reentrant tachycardia (AVNRT) in 77 (53%), atrioventricular reciprocating tachycardia (AVRT) in 51 (35%), and atrial tachycardia (AT) in 17 (12%). A higher ISP dose was required for AT compared to other PSVT (AVNRT: 0.06 (IQR 0.03‐0.06) vs AVRT: 0.03 (0.02‐0.06) vs AT: 0.06 (0.03‐0.12) mg/h, P = .013). More than half (51%) of the patients developed hypotension requiring phenylephrine; these patients were older. Acute success was obtained in 99% (patients with AVNRT had endpoints with single echo on ISP in 46%). Long‐term success rate was 136 of 144 (94%) (AVNRT 96%, AVRT 92%, and AT 93%). There were no complications related to deep sedation. Conclusions Deep sedation with use of ASV is a feasible anesthesia strategy for catheter ablation of PSVT with good long‐term outcome. PSVT remains inducible if ISP is used.
Aims: Catheter ablation for premature ventricular contractions (PVCs) triggering ventricular fibrillation (VF) after acute myocardial infarction (AMI) has proven effective, with Purkinje potentials often serving as the target. However, the electrophysiological features of Purkinje potentials and their relationship with the conduction system in VF-triggering PVCs remain unclear. Methods: This multicentre retrospective study analysed patients who underwent catheter ablation for VF-triggering PVCs during the acute or subacute phase of AMI. Characteristics of Purkinje potentials, including retrograde conduction from the Purkinje network and subsequent anterograde conduction to the right bundle branch (RB), were evaluated for PVC morphology. Results: Fifty-three patients (mean age 66±11 years; 13% female) with 67 VF-triggering PVCs were analysed. The mean PVC width was 157 ± 42 ms, with 87% showing RB branch block morphology. Purkinje potentials preceded 72% of PVCs (mean interval 68 ± 42 ms). PVCs with preceding Purkinje potentials had narrower QRS duration (145 ± 26 ms vs. 198 ± 57 ms, P < 0.0001). The coupling interval from the preceding sinus beat was inversely correlated with the interval from Purkinje potential to PVC onset (P < 0.0001). Retrograde Purkinje conduction with subsequent anterograde RB conduction was identified in 9%. In these cases, the coupling interval from the preceding sinus beat was longer (391 ± 12 ms vs. 467 ± 34 ms, P = 0.041). Conclusion: Purkinje potentials show distinct properties that influence both QRS duration and PVC timing. The presence of preceding Purkinje potentials together with QRS duration may help guide ablation strategies. In rare cases, Purkinje activity conducts retrogradely from the left bundle and anterogradely through the RB, modifying PVC morphology.