The introduction and designing of functional thermoresponsive hydrogels have been recommended as recent potential therapeutic approaches for biomedical applications. The development of bioactive materials such as thermosensitive gelatin-incorporated nano-organic materials with a porous structure and photothermally triggerable and cell adhesion properties may potentially achieve this goal. This novel class of photothermal hydrogels can provide an advantage of hyperthermia together with a reversibly transformable hydrogel for tissue engineering. Polypyrrole (Ppy) is a bioorganic conducting polymeric substance and has long been used in biomedical applications owing to its brilliant stability, electrically conductive features, and excellent absorbance around the near-infrared (NIR) region. In this study, a cationic photothermal triggerable/guidable gelatin hydrogel containing a polyethylenimine (PEI)–Ppy nanocomplex with a porous microstructure was established, and its physicochemical characteristics were studied through dynamic light scattering, scanning electronic microscopy, transmission electron microscopy, an FTIR; and cellular interaction behaviors towards fibroblasts incubated with a test sample were examined via MTT assay and fluorescence microscopy. Photothermal performance was evaluated. Furthermore, the in vivo study was performed on male Wistar rat full thickness excisions model for checking the safety and efficacy of the designed gelatin–PEI–Ppy nanohydrogel system in wound healing and for other biomedical uses in future. This photothermally sensitive hydrogel system has an NIR-triggerable property that provides local hyperthermic temperature by PEI–Ppy nanoparticles for tissue engineering applications. Features of the designed hydrogel may fill other niches, such as being an antibacterial agent, generation of free radicals to further improve wound healing, and remodeling of the promising photothermal therapy for future tissue engineering applications.
Autologous skin grafts, which can cause donor site morbidity, are currently used to treat deep wounds. To improve the regeneration of poorly healing wounds, cell-derived extracellular matrix (ECM) scaffolds are garnering great research interest due to their associated lower risks of pathogen transfer and immune rejection. However, the mechanical properties of cell-derived ECM scaffolds are inferior when compared to those of tissue-derived ECM scaffolds. To overcome this drawback, different amounts (10, 20, 50, and 100 μg mL−1) of graphene oxide (GO) and genipin (1% w/v) were applied to adipose stem cell (ASC)-derived ECM sponges. There are still only a few studies employing cell-derived extracellular matrices as biomimetic scaffolds for biomedical applications. The aim of our study was to develop biocompatible, biodegradable, low immunogenic, and genipin-crosslinked ASC-derived ECM sponges containing a suitable amount of GO for skin-tissue engineering. Sponges were fabricated using cultures of ASCs, cell sheets, and decellularization of an ASC cell sheet, freeze-thawing, and crosslinking in a sequential manner. Scanning electron microscopic analyses of the sponges demonstrated a highly porous microstructure with a pore size of 71.22 ± 19.52 μm. The in vitro degradation rate was found to be significantly higher in the non-crosslinked ECM sponges and pure ECM sponges than in the genipin-crosslinked ECM sponges. During an in vivo study, we investigated the material feasibilities and degradability of the constructed ECM sponges as a suitable skin tissue-engineering scaffold in a xenogenic animal (rat) model for 4 weeks. After subcutaneous implantation, the ECM sponges containing a medium amount of GO showed appropriate biodegradation with a lower inflammatory reaction. Hence, the fabricated ECM sponges might be a suitable xenogenous skin substitute for full-thickness skin defects and in other future soft-tissue engineering applications, such as healing partial tears of the anterior cruciate ligament.
Mg-based alloys have great potential for development into fixation implants because of their highly biocompatible and biodegradable metallic properties. In this study, we sought to determine the biocompatibility of Mg60Zn35Ca5 bulk metallic glass composite (BMGC) with fabricated implants in a rabbit tendon–bone interference fixation model. We investigated the cellular cytotoxicity of Mg60Zn35Ca5 BMGC toward rabbit osteoblasts and compared it with conventional titanium alloy (Ti6Al4V) and polylactic acid (PLA). The results show that Mg60Zn35Ca5 BMGC may be classed as slightly toxic on the basis of the standard ISO 10993-5. We further characterized the osteogenic effect of the Mg60Zn35Ca5 BMGC extraction medium on rabbit osteoblasts by quantifying extracellular calcium and mineral deposition, as well as cellular alkaline phosphatase activity. The results of these tests were found to be promising. The chemotactic effect of the Mg60Zn35Ca5 BMGC extraction medium on rabbit osteoblasts was demonstrated through a transwell migration assay. For the in vivo section of this study, a rabbit tendon–bone interference fixation model was established to determine the biocompatibility and osteogenic potential of Mg60Zn35Ca5 BMGC in a created bony tunnel for a period of up to 24 weeks. The results show that Mg60Zn35Ca5 BMGC induced considerable new bone formation at the implant site in comparison with conventional titanium alloy after 24 weeks of implantation. In conclusion, this study revealed that Mg60Zn35Ca5 BMGC demonstrated adequate biocompatibility and exhibited significant osteogenic potential both in vitro and in vivo. These advantages may be clinically beneficial to the development of Mg60Zn35Ca5 BMGC implants for future applications.
18 September 2023 in ACS Applied Materials & Interfaces