Bystander cardiopulmonary dresuscitation (CPR) improves the survival and neurological outcomes of sudden cardiac arrest patients. The rate of bystander CPR is increasing; however, its performance quality has not been evaluated in detail. In this study, emergency medical technicians (EMTs) in the field evaluated bystander CPR quality, and we aimed to investigate the association between bystander information and CPR quality. This retrospective cohort study was based on data included in the Smart Advanced Life Support (SALS) registry between January 2016 and December 2017. We included patients older than 18 years who experienced an out-of-hospital cardiac arrest (OHCA) due to medical causes. Bystander CPR quality was judged to be “high” when the hand positions were appropriate and when compression rates of at least 100/min and compression depths of at least 5 cm were achieved. Among 6,769 eligible patients, 3,799 (58.7%) received bystander CPR, and 6% of bystanders performed high-quality CPR. After adjustment, the occurrence of cardiac arrest at home (adjusted odds ratio (aOR), 95% confidence interval (CI); 0.42, 0.27–0.64), witnessed cardiac arrest (1.45, 1.03–2.06), and younger bystander age all showed associations with one another. High-quality CPR led to a 4.29-fold increase in the chance of neurological recovery. In particular, high-quality CPR in patients aged 60 years showed a significant association compared with other age groups (7.61, 1.41–41.04). The main factor affecting CPR quality in this study was the age of the bystander, and older bystanders found it more difficult to maintain CPR quality. To improve the quality of bystander CPR, training among older bystanders should be the focus.
1 October 2014 in The American Journal of Emergency Medicine
We hypothesized that novices would be able to use the McGrath MAC (Aircraft Medical Ltd, Edinburgh, UK) equally as well as the GlideScope Ranger (Verathon, Inc, Bothell, WA) for intubation in regular simulated airways. We performed a prospective, randomized crossover study of 39 medical students using the McGrath MAC, GlideScope Ranger, and Macintosh in a manikin with 2 normal airways. The primary outcome was the intubation time. Secondary outcomes included the success rates and the overall glottic view of the 3 laryngoscopes. The mean intubation times for each attempt with the McGrath MAC were 30.8 ± 16.9 seconds or less and did not differ significantly from those obtained with the GlideScope Ranger or the Macintosh in both airway scenarios (P = .18; P = .49). The mean success rates at each attempt with the McGrath MAC were 82.0% ± 38.8% or more, equal to the Macintosh and the GlideScope Ranger in both scenarios (P = .026; P = .72) except during the first intubation attempt in a normal airway (P = .008). The median grades of the glottic view visible at each intubation attempt with the McGrath Mac were Cormack-Lehane grade 1 (scenario 1: interquartile range, 1-1; scenario 2: interquartile range, 1-2), which was significantly better than the Macintosh laryngoscope in both scenarios. However, the McGrath Mac did not produce a better glottic view than the GlideScope Ranger with either scenario. The intubation performance of novices using the McGrath MAC was equal to their performance using the GlideScope Ranger in regular simulated airways.
Objective The purpose of this study was to assess whether a photoplethysmography (PPG) sensor in a smart watch can accurately recognise the return of spontaneous circulation (ROSC) in cardiac arrest patients compared with carotid artery palpation. Methods This prospective observational study was conducted on 50 out-of-hospital cardiac arrest patients who visited the emergency department (ED) of one tertiary hospital. As soon as the patient arrived at the ED, advanced cardiac life support was carried out immediately. At this time, three smart watches were attached to the carotid artery, forehead and wrist and were checked for pulse measurements every 2 min. In the case of ROSC, blood pressure, heart rate and heart rate regularity were confirmed, and pulse was simultaneously measured at three sites with smart watches. In the case of no ROSC, only the pulse was measured at three sites with the smart watches. Results There were 33 males (66%) and the mean age was 68±11.57 years. In 14 patients (28%), spontaneous circulation was recovered through cardiopulmonary resuscitation, and all survived. The sensitivity and specificity of manual palpation were 78.6% and 90.4%, respectively. False-positive and false-negative rates were 9.6% and 21.4%, respectively. Smart watches at all three sites had the same or higher sensitivity than manual palpation. The sensitivity of the smart watch was the highest, at 100%, in the carotid region and the lowest, at 78.6%, in the wrist region. The specificity of the smart watch was the highest, at 100%, in the wrist region and the lowest, at 78.7%, in the carotid region. Conclusion Compared with manual pulse check, the PPG sensor embedded in the smart watch showed the same sensitivity and a higher specificity for recognising ROSC when measured at the wrist.
1 April 2019 in The American Journal of Emergency Medicine
Increased body mass index (BMI) is a risk factor for cardiovascular disease, stroke, and metabolic diseases. A high BMI may affect outcomes of post-cardiac arrest patients, but the association remains debatable. We aimed to determine the association between BMI and outcomes in patients with return of spontaneous circulation (ROSC) after out-of-hospital cardiac arrest (OHCA). A systematic literature search was conducted using MEDLINE, EMBASE, and the Cochrane Library. Studies that included patients who presented ROSC after OHCA, had a recorded BMI, and were assessed for neurological outcomes and in-hospital mortality were included. To assess the risk of bias of each included study, we employed the Risk of Bias Assessment Tool for Non-randomized Studies. We assessed 2427 patients from six studies. Neurological outcomes were significantly poorer in underweight patients (risk ratio (RR) = 1.21; 95% confidence interval (CI) = 1.07–1.37; p = 0.002; I2 = 51%) than in normal-weight patients. Additionally, in-hospital mortality rate was significantly higher in underweight patients (RR = 1.35; 95% CI = 1.14–1.60; p<0.001; I2 = 21%) and in obese patients (RR = 1.25; 95% CI = 1.12–1.39; p<0.001; I2 = 0%) than in normal-weight patients. Poor neurological outcome is associated with underweight, and low survival rate is associated with underweight and obesity in patients with ROSC after OHCA.