In order to overcome the downside of long conventional freeze-drying (CFD) process times for monoclonal antibody formulations, microwave-assisted freeze-drying (MFD) was introduced. Recently, the general applicability and potential shortening of drying times were shown. However, little is known about the storage stability of MFD products compared to CFD references. Additionally, batch homogeneity issues were seen within MFD in the past. In this study, we examined four different formulations of two different monoclonal antibodies using three different glass-forming excipients: sucrose, trehalose, and arginine phosphate. These formulations were freeze-dried with two different drying protocols (CFD and MFD), stored for 24 weeks, and analyzed for solid-state and protein-related quality attributes. Moreover, a new microwave generator setup was investigated for its potential to improve batch homogeneity. In all investigated formulations, comparable stability profiles were found, although the classical magnetron generator led to inferior batch homogeneity with respect to residual moisture distribution. In contrast, the new MFD setup indicated the potential to approximate batch homogeneity to the level of CFD. However, for future applications, there is an unabated need for new machine designs to comply with pharmaceutical manufacturing requirements.
Recently, attention has been drawn to microwave-assisted freeze-drying (MFD), as it drastically reduces the typically long drying times of biopharmaceuticals in conventional freeze-drying (CFD). Nevertheless, previously described prototype machines lack important attributes such as in-chamber freezing and stoppering, not allowing for the performance of representative vial freeze-drying processes. In this study, we present a new technical MFD setup, designed with GMP processes in mind. It is based on a standard lyophilizer equipped with flat semiconductor microwave modules. The idea was to enable the retrofitting of standard freeze-dryers with a microwave option, which would reduce the hurdles of implementation. We aimed to collect process data with respect to the speed, settings, and controllability of the MFD processes. Moreover, we studied the performance of six monoclonal antibody (mAb) formulations in terms of quality after drying and stability after storage for 6 months. We found drying processes to be drastically shortened and well controllable and observed no signs of plasma discharge. The characterization of the lyophilizates revealed an elegant cake appearance and remarkably good stability in the mAb after MFD. Furthermore, overall storage stability was good, even when residual moisture was increased due to high concentrations of glass-forming excipients. A direct comparison of stability data following MFD and CFD demonstrated similar stability profiles. We conclude that the new machine design is highly advantageous, enabling the fast-drying of excipient-dominated, low-concentrated mAb formulations in compliance with modern manufacturing technology.
Microwave-assisted freeze-drying (MFD) offers significant time savings compared to conventional freeze-drying (CFD). While a few studies have investigated the stability of biopharmaceuticals with low protein concentrations after MFD and storage, the impact of MFD on high-concentration monoclonal antibody (mAb) formulations remains unclear. In this study, we systematically examined the effect of protein concentration in MFD and assessed protein stability following MFD, CFD, and subsequent storage using seven protein formulations with various stabilizers and concentrations. We demonstrated that microwaves directly interact with the active pharmaceutical ingredient (API), leading to decreased physical stability, specifically aggregation, in high-concentration antibody formulations. Furthermore, typically used sugar:protein ratios from CFD were insufficient for stabilizing mAbs when applying microwaves. We identified the intermediate drying phase as the most critical for particle formation, and cooling the samples provided some protection for the mAb. Our findings suggest that MFD technology may not be universally applicable to formulations well tested in CFD and could be particularly beneficial for formulations with low API concentrations requiring substantial amounts of glass-forming excipients, such as vaccines and RNA-based products.
15 June 2021 in PDA Journal of Pharmaceutical Science and Technology
Freeze-drying is the drying technology of choice for sensitive biological drugs. On the one side, it is admired for its suitability for the stabilization of sensitive molecules. On the other side, it is a time-consuming production step posing challenges in process development and technology transfer. The application of controlled ice nucleation is one elegant approach to shorten freeze-drying times significantly and at the same time increasing batch homogeneity. However, a reliable 100% control of the controlled nucleation step in each vial is essential considering the impact of the nucleation temperature on product quality attributes. In this study, we introduce a camera-supported optical inspection method that utilizes the different superficial cake structures seen in controlled and random nucleated lyophilizates. Derived from the grayscale analysis the new distinguishing criterion ″average edge brightness″ is introduced. Four different formulations containing Sucrose, Trehalose, and/or BSA were freeze-dried with random or controlled nucleation and analyzed with the new technology. A proof of concept is provided by the analysis of a similar-to-market lyophilized monoclonal antibody formulation freeze-dried with three different freezing protocols covering different nucleation profiles. For all investigated formulations and process conditions, the clear discrimination of controlled and randomly nucleated vials was possible. By this, the technology allowed for reliable, non-invasive, and automatable 100% monitoring of controlled nucleation success after freeze-drying.