Recombinant adeno-associated virus (rAAV) vectors have evolved as one of the most promising technologies for gene therapy due to their good safety profile, high transduction efficacy, and long-term gene expression in nondividing cells. rAAV-based gene therapy holds great promise for treating genetic disorders like inherited blindness, muscular atrophy, or bleeding disorders. There is a high demand for efficient and scalable production and purification methods for rAAVs. This is particularly true for the downstream purification methods. The current standard methods are based on multiple steps of gradient ultracentrifugation, which allow for the purification and enrichment of full rAAV particles, but the scale up of this method is challenging. Here, we explored fast, scalable, and universal liquid chromatography-based strategies for the purification of rAAVs. In contrast to the hydrophobic interaction chromatography (HIC), where a substantial amount of AAV was lost, the cation exchange chromatography (CEX) was performed robustly for multiple tested serotypes and resulted in a mixture of full and empty rAAVs with a good purity profile. For the used affinity chromatography (AC), a serotype dependence was observed. Anion exchange chromatography (AEX) worked well for the AAV8 serotype and achieved high levels of purification and a baseline separation of full and empty rAAVs. Depending on the AAV serotype, a combination of CEX and AEX or AC and AEX is recommended and holds promise for future translational projects that require highly pure and full particle-enriched rAAVs.
In order to overcome the downside of long conventional freeze-drying (CFD) process times for monoclonal antibody formulations, microwave-assisted freeze-drying (MFD) was introduced. Recently, the general applicability and potential shortening of drying times were shown. However, little is known about the storage stability of MFD products compared to CFD references. Additionally, batch homogeneity issues were seen within MFD in the past. In this study, we examined four different formulations of two different monoclonal antibodies using three different glass-forming excipients: sucrose, trehalose, and arginine phosphate. These formulations were freeze-dried with two different drying protocols (CFD and MFD), stored for 24 weeks, and analyzed for solid-state and protein-related quality attributes. Moreover, a new microwave generator setup was investigated for its potential to improve batch homogeneity. In all investigated formulations, comparable stability profiles were found, although the classical magnetron generator led to inferior batch homogeneity with respect to residual moisture distribution. In contrast, the new MFD setup indicated the potential to approximate batch homogeneity to the level of CFD. However, for future applications, there is an unabated need for new machine designs to comply with pharmaceutical manufacturing requirements.
Recently, attention has been drawn to microwave-assisted freeze-drying (MFD), as it drastically reduces the typically long drying times of biopharmaceuticals in conventional freeze-drying (CFD). Nevertheless, previously described prototype machines lack important attributes such as in-chamber freezing and stoppering, not allowing for the performance of representative vial freeze-drying processes. In this study, we present a new technical MFD setup, designed with GMP processes in mind. It is based on a standard lyophilizer equipped with flat semiconductor microwave modules. The idea was to enable the retrofitting of standard freeze-dryers with a microwave option, which would reduce the hurdles of implementation. We aimed to collect process data with respect to the speed, settings, and controllability of the MFD processes. Moreover, we studied the performance of six monoclonal antibody (mAb) formulations in terms of quality after drying and stability after storage for 6 months. We found drying processes to be drastically shortened and well controllable and observed no signs of plasma discharge. The characterization of the lyophilizates revealed an elegant cake appearance and remarkably good stability in the mAb after MFD. Furthermore, overall storage stability was good, even when residual moisture was increased due to high concentrations of glass-forming excipients. A direct comparison of stability data following MFD and CFD demonstrated similar stability profiles. We conclude that the new machine design is highly advantageous, enabling the fast-drying of excipient-dominated, low-concentrated mAb formulations in compliance with modern manufacturing technology.
Studying the thermal history and relaxation of solid amorphous drug product matrices by calorimetry is a well-known approach, particularly in the context of correlating the matrix parameters with the long-term stability of freeze-dried protein drug products. Such calorimetric investigations are even more relevant today, as the application of new process techniques in freeze-drying (which strongly influence the thermal history of the products) has recently gained more interest. To revive the application of calorimetric methods, the widely scattered knowledge on this matter is condensed into a review and completed with new experimental data. The calorimetric methods are applied to recent techniques in lyophilization, such as controlled nucleation and aggressive/collapse drying. Phenomena such as pre-Tg events in differential scanning calorimetry and aging shoulders in isothermal microcalorimetry are critically reviewed and supplemented with data of freeze-dried products that have not been characterized with these methods before.
1 August 2018 in European Journal of Pharmaceutics and Biopharmaceutics
Primary containers made of cyclic olefin polymer (COP) have recently gained attention since they may overcome several risks and shortcomings of glass containers as they exhibit a high break resistance, biocompatibility, and homogeneous heat transfer during lyophilization. On the downside, COP is more permeable for gases, which can lead to an ingress of oxygen into the container over time. Since oxidation is an important degradation pathway for monoclonal antibodies (mAbs), the continuous migration of oxygen into drug product containers should be avoided overall. To date, no long-term stability studies regarding lyophilizates in polymer vials have been published, potentially because of the unbearable gas permeability. In this study, we demonstrate that after lyophilization in COP vials and storage of these vials in aluminum pouches together with combined oxygen and moisture absorbers (“smart packaging”), oxidation of two lyophilized therapeutic antibodies was as low as in glass vials due to the deoxygenated environment in the pouch. Nevertheless, active removal of oxygen from the primary container below the initial level over time during storage in such “smart” secondary packaging was not achieved. Furthermore, residual moisture was controlled. Overall, the smart packaging reveals a promising approach for long-term stability of biopharmaceuticals; in addition to COP’s known benefits, stable, low oxygen and moisture levels as well as the protection from light and cushioning against mechanical shock by the secondary packaging preserve the sensitive products very well.