Ondřej Nentvich

Mr. Ondřej Nentvich

Radioelectronics, Czech Technical University in Prague, Prague, Praha, Hlavní Město, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Acta Astronautica
Verified
Journal Article
Closed access
MUMartin Urban
Martin Urban
Ondřej NentvichOndřej Nentvich
Ondřej Nentvich
VSVeronika Stehlikova
Veronika Stehlikova
TBTomas Baca
Tomas Baca
VDVladimir Daniel
Vladimir Daniel
RHRene Hudec
Rene Hudec

1 October 2016 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
TBTomáš Báča
Tomáš Báča
MPM. Platkevic
M. Platkevic
JJJ. Jakubek
J. Jakubek
AIA. Inneman
A. Inneman
VSV. Stehlikova
V. Stehlikova
VDV. Daniel
V. Daniel

15 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MUMartin Urban
Martin Urban
Ondřej NentvichOndřej Nentvich
Ondřej Nentvich
LMLukas Marek
Lukas Marek
RHRene Hudec
Rene Hudec
LSLadislav Sieger
Ladislav Sieger
The Timepix3 readout ASIC chip is a hybrid pixelated radiation detector, designed at CERN, which contains a 256 px × 256 px matrix. Each of the 65,536 radiation-sensitive pixels can record an incoming particle, its energy deposition or time of arrival and measure them simultaneously. Since the detector is suitable for a wide range of applications from particle physics, national security and medicine to space science, it can be used in a wide range of temperatures. Until now, it has to be calibrated every time to the operating point of the application. This paper studies the possibility of energy measurement with Timepix3 equipped with a 500 m thick silicon sensor and MiniPIX readout interface in the temperatures between 10 ∘C and 70 ∘C with only one calibration. The detector has been irradiated by X-ray fluorescence photons in the energy range from 8 keV to 57 keV, and 31 keV to 81 keV photons from the 133Ba radioactive source. A deviation of 5% in apparent energy value may occur for a 10 ∘C change in temperature from the reference point, but, with the next temperature change, it can reach up to −30%. Moreover, Barium photons with an energy of 81 keV appear as deposited energy of only 55 keV at a detector temperature of 70 ∘C. An original compensation method that reduces the relative measurement error from −30% to less than 1% is presented in this paper.

1 July 2019 in Space Science Reviews
Verified
Journal Article
Closed access
PDF file
VDVladimir Dániel
Vladimir Dániel
AIA. Inneman
A. Inneman
IVI. Vertat
I. Vertat
TBTomáš Báča
Tomáš Báča
Ondřej NentvichOndřej Nentvich
Ondřej Nentvich
RPR. Pavlica
R. Pavlica

19 September 2016
Verified
Conference Paper
Closed access
PDF file
VDV. Dániel
V. Dániel
LPL. Pína
L. Pína
AIA. Inneman
A. Inneman
VZV. Zadražil
V. Zadražil
TBT. Báča
T. Báča
MUMartin Urban
Martin Urban

31 May 2017
Verified
Conference Paper
Closed access
PDF file
VDV. Dániel
V. Dániel
AIA. Inneman
A. Inneman
LPL. Pína
L. Pína
VZV. Zadražil
V. Zadražil
TBT. Báča
T. Báča
TST. Schulz
T. Schulz