Ji Hoon Bahk

Dr. Ji Hoon Bahk

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
JBJi Hoon Bahk
Ji Hoon Bahk
YKYoung-Hoon Kim
Young-Hoon Kim
HPHyung-youl Park
Hyung-youl Park
HMHyung-Ki Min
Hyung-Ki Min
SKSangil Kim
Sangil Kim
KHKee-Yong Ha
Kee-Yong Ha
Bahk JH, et al. J Korean Med Sci. 2020 Sep;35(40):e345. https://doi.org/10.3346/jkms.2020.35.e345

20 December 2021 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
JBJi Hoon Bahk
Ji Hoon Bahk
WJWoo-Lam Jo
Woo-Lam Jo
SKSeung-Chan Kim
Seung-Chan Kim
SKSoon-Yong Kwon
Soon-Yong Kwon
YLYoung Wook Lim
Young Wook Lim
Background: This study was designed as a cohort study using propensity-score matching to age, gender, and body mass index (BMI) for finite element model (FEM) analysis from pre-collapse CT images of collapsed and non-collapsed hips. Through FEM analysis, a global graphical output around the hip joint can provide simple impression of stress distribution: concentration or dispersion. Methods: A total of 32 hips with ARCO stage 2 or 3 ONFH who were on follow up for over a one-year period were retrospectively reviewed. 16 hips with no interval progression of collapse were set as the study group, then 16 hips with progression of collapse which required arthroplasty were set as the control group using propensity-score matching. FEM was generated through Mechanical Finder for each patient, then 4500 N of load was applied to 1000 mm2 area at the top of iliac crest to analyze the models in terms of equivalents for yield stress. Results: Age, sex, and BMI had no significant differences between the two groups, while location (p = 0.015) was lateral, and size (p = 0.015) was significantly greater in the collapsed group. Non-collapsed hips mostly exhibited stress dispersion allocated to medial and lateral pillars, while collapsed hips exhibited stress concentration focused on the lateral pillar and the primary compression trabecula. (p = 0.001). Conclusion: Through FEM analysis, stress concentration to the lateral pillar and the primary compression trabeculae can be used to predict future collapse in ONFH with high probability. Results provide a simple and intuitive, yet valuable information to aid surgeons. Therefore, especially for young patients, holding out the lateral pillar through joint preserving procedures might be the key in preventing further collapse.

12 May 2023 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
HNHo-Jin Nam
Ho-Jin Nam
YLYoung Wook Lim
Young Wook Lim
WJWoo-Lam Jo
Woo-Lam Jo
JBJi Hoon Bahk
Ji Hoon Bahk
SKSoon-Yong Kwon
Soon-Yong Kwon
SASaad Mohammed Alshammari
Saad Mohammed Alshammari
Background: In revision surgery with significant segmental acetabular defects, adequate implant selection and fixation methods are critical in determining successful bony ingrowth. Commercially available total hip prosthesis manufacturers generally offer additional multi-hole options of acetabular shells with identical designs for use in revision THAs where screw holes configurations vary from product to product. This study aims to compare the mechanical stability of the two types of acetabular screw constructs for the fixation of acetabular components: spread-out and pelvic brim-focused configurations. Methods: We prepared 40 synthetic bone models of the male pelvis. In half of the samples with acetabular defects, identical curvilinear bone defects were manually created using an oscillating electrical saw. On the right side, multi-hole-cups in which the direction of the screw holes are centered on the pelvic brim (brim-focused) and, on the left side, multi-hole-cups with the direction of the screw hole spread throughout the acetabulum (spread-out) were implanted into the pelvic synthetic bones. Coronal lever-out and axial torsion tests were performed with a testing machine, measuring load versus displacement. Results: The average torsional strengths were significantly higher in the spread-out group over the brim-focused group regardless of the presence of the segmental defect of the acetabulum (p < 0.001). But for the lever-out strength, the spread-out group exhibited significantly higher average strength over the brim-focused group for the intact acetabulum (p = 0.004), whereas the results were reversed in the brim-focused group when the defects were generated (p < 0.001). The presence of acetabular defects reduced the average torsional strengths of the two groups by 68.66% versus 70.86%. In comparison, the decrease in the average lever-out strength was less significant for the brim-focused group than the spread-out group (19.87% vs. 34.25%) (p < 0.001). Conclusion: Constructs of multi-hole acetabular cups with the spread-out screw holes configuration exhibited statistically better axial torsional strength and coronal lever-out strength. With the presence of posterior segmental bone defects, the spread-out constructs demonstrated significantly better tolerance to axial torsional strength. Still, they exhibited inverted results of higher lever-out strength in the pelvic brim-focused constructs.

10 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JBJi Hoon Bahk
Ji Hoon Bahk
Seung-Beom HanSeung-Beom Han
Seung-Beom Han
KRKee Hyung Rhyu
Kee Hyung Rhyu
JYJeong Joon Yoo
Jeong Joon Yoo
SEUNG JAE LIMSEUNG JAE LIM
SEUNG JAE LIM
YLYoung Wook Lim
Young Wook Lim
Background: Recent advancements in hip arthroplasty aim to enhance the stability, longevity, and functionality of femoral implants. However, the distal fitting of femoral stems, often caused by metaphyseal–diaphyseal mismatch, remains a significant issue, particularly in patients with Dorr type A femora. Such mismatches can result in suboptimal implant performance, leading to potential complications. This study focuses on evaluating the anatomical compatibility of five representative single-tapered wedge mid–short stems with the mediolateral (ML) anatomy of the proximal femur in an East Asian population, where these mismatches are often more pronounced. Methods: A total of 742 patients from two hospitals, all of whom underwent unilateral primary total hip arthroplasty, were included in the study. The contralateral proximal femur was confirmed to have normal anatomy in each patient. Hip anteroposterior radiographs were used for measurements, which were standardized in conjunction with CT images. Key anatomical parameters were measured, including proximal and distal medial–lateral canal dimensions, vertical offset, and medial offset. Five femoral stem designs—Tri-lock®, Taperloc®, Anthology®, Accolade II®, and Fit®—were evaluated. R programming was employed for a detailed fit analysis to match stem sizes with patient anatomy, categorizing the fit as proximal, simultaneous proximal–distal, or distal engagement. Results: Among the femoral stems analyzed, the Fit® stem demonstrated the closest alignment with the regression line for ML widths in the study population (slope = 0.69; population ML slope = 0.38). This was followed by Accolade II®, which had a slope of 0.83. In terms of offset options, the Accolade II® offered the largest offset coverage, making it particularly suitable for this population. The fit analysis revealed that the Fit® stem had the highest suitable fit rate (90.56%), followed by Accolade II® (73.04%). Taperloc®, Anthology®, and Tri-lock® had similar fit rates of approximately 59%. Overall, optimal results were obtained for 92.05% of the population in the automated fitting trial, regardless of the product type. Conclusions: When designing modern cementless femoral stems intended for press-fit fixation, it is crucial to account for the anatomical variations specific to the target population. In this study, Fit® and Accolade II® femoral components demonstrated superior compatibility with the femoral anatomy of the East Asian population, particularly in those with a higher incidence of Dorr type A femora. These stems, characterized by slimmer distal dimensions and high-offset options, appear to minimize metaphyseal–diaphyseal mismatch and associated complications.

18 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JBJi Hoon Bahk
Ji Hoon Bahk
WJWoo-Lam Jo
Woo-Lam Jo
SKSoon-Yong Kwon
Soon-Yong Kwon
HPHyung Chul Park
Hyung Chul Park
YLYoung Wook Lim
Young Wook Lim
High-dose bisphosphonate for multiple myeloma patients might elevate risks of skeletal complications earlier than general expectations. This study aims to find incidences of atypical femoral fracture (AFF) and medication-related osteonecrosis of the jaw (MRONJ), elucidate their risk factors, and suggest cut-off values for the safer dosing of high-dose bisphosphonate treatment. By using the clinical data warehouse of a single institute, retrospective cohort data of multiple myeloma-diagnosed patients with high-dose bisphosphonate (pamidronate or zoledronate) treatment from 2009 to 2019 was extracted. Among 644 patients, the incidence of prominent AFF requiring surgery was 0.93% (6/644) and MRONJ was diagnosed in 11.8% (76/644) of the study population. For both AFF and MRONJ, the total potency-weighted sum of total dose per body weight (OR = 1.010, p = 0.005) were significant on logistic regression. Cutoffs of the potency-weighted total dose (mg) per body weight (kg) for AFF and MRONJ were 77.00 and 57.70 mg/kg, respectively. After roughly one year of treatment with high-dose zoledronate (about four years for pamidronate), an earlier thorough re-evaluation of skeletal complications should be taken. Body weight adjustments for accumulative dose calculation in terms of permissible dosing should be taken into consideration.

Verified
Journal Article
Open access
PDF file
JBJi Hoon Bahk
Ji Hoon Bahk
WJWoo-Lam Jo
Woo-Lam Jo
KLKee-Haeng Lee
Kee-Haeng Lee
JSJoo-Hyoun Song
Joo-Hyoun Song
SKSeung-Chan Kim
Seung-Chan Kim
YLYoung Wook Lim
Young Wook Lim
Background/Objectives: Additive manufacturing (AM) enables the production of cementless acetabular cups with porous surfaces that facilitate early osseointegration. Directed energy deposition (DED), a form of AM, allows the direct welding of porous structures onto metal substrates without requiring a vacuum environment, offering advantages over conventional powder bed fusion methods. Despite growing interest in DED, no prospective clinical studies evaluating DED-based acetabular components have been published to date. This study assessed short-term outcomes of a DED-based 3D-printed acetabular cup in total hip arthroplasty (THA). Methods: A total of 120 patients who underwent primary cementless THA using the Corentec Mirabo Z® acetabular cup were prospectively enrolled. Among them, 124 hips from 100 patients who had completed a minimum of 24 months of follow-up were included in the analysis. Clinical outcomes were assessed using the Harris hip score (HHS), WOMAC, EQ-5D-5L, and pain NRS. Radiographic evaluation included measurements of cup position, osseointegration, and detection of interfacial or polar gaps on CT and plain radiographs. Implant-related complications were also recorded. Results: At a mean follow-up of 34.6 months, the implant survival rate was 99.3%, with one revision due to suspected osseointegration failure. The HHS improved from 56.6 to 91.4 at 24 months, and the NRS decreased from 6.2 to 1.1 (both p < 0.001). Interfacial gaps were observed in 58.1% of cases on CT, though most were <1 mm and not clinically significant. Common postoperative issues included greater trochanteric pain syndrome, squeaking, and iliotibial band tightness, all of which were resolved with conservative treatment. Conclusions: DED-based 3D-printed acetabular cups demonstrated favorable short-term clinical and radiographic outcomes, with high survivorship and reliable early osseointegration in cementless THA.