Joo-Hyoun Song

Prof. Dr. Joo-Hyoun Song


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2014 in Hip & Pelvis
Verified
Journal Article
Open access
PDF file
YKYoon-Chung (Sophie) Kim
Yoon-Chung (Sophie) Kim
JLJoo-Yup Lee
Joo-Yup Lee
JSJoo-Hyoun Song
Joo-Hyoun Song
SOSeungbae Oh
Seungbae Oh
Kim YC, et al. Hip Pelvis. 2014 Dec;26(4):263-268. http://dx.doi.org/10.5371/hp.2014.26.4.263

Verified
Journal Article
Open access
PDF file
JBJi Hoon Bahk
Ji Hoon Bahk
WJWoo-Lam Jo
Woo-Lam Jo
KLKee-Haeng Lee
Kee-Haeng Lee
JSJoo-Hyoun Song
Joo-Hyoun Song
SKSeung-Chan Kim
Seung-Chan Kim
YLYoung Wook Lim
Young Wook Lim
Background/Objectives: Additive manufacturing (AM) enables the production of cementless acetabular cups with porous surfaces that facilitate early osseointegration. Directed energy deposition (DED), a form of AM, allows the direct welding of porous structures onto metal substrates without requiring a vacuum environment, offering advantages over conventional powder bed fusion methods. Despite growing interest in DED, no prospective clinical studies evaluating DED-based acetabular components have been published to date. This study assessed short-term outcomes of a DED-based 3D-printed acetabular cup in total hip arthroplasty (THA). Methods: A total of 120 patients who underwent primary cementless THA using the Corentec Mirabo Z® acetabular cup were prospectively enrolled. Among them, 124 hips from 100 patients who had completed a minimum of 24 months of follow-up were included in the analysis. Clinical outcomes were assessed using the Harris hip score (HHS), WOMAC, EQ-5D-5L, and pain NRS. Radiographic evaluation included measurements of cup position, osseointegration, and detection of interfacial or polar gaps on CT and plain radiographs. Implant-related complications were also recorded. Results: At a mean follow-up of 34.6 months, the implant survival rate was 99.3%, with one revision due to suspected osseointegration failure. The HHS improved from 56.6 to 91.4 at 24 months, and the NRS decreased from 6.2 to 1.1 (both p < 0.001). Interfacial gaps were observed in 58.1% of cases on CT, though most were <1 mm and not clinically significant. Common postoperative issues included greater trochanteric pain syndrome, squeaking, and iliotibial band tightness, all of which were resolved with conservative treatment. Conclusions: DED-based 3D-printed acetabular cups demonstrated favorable short-term clinical and radiographic outcomes, with high survivorship and reliable early osseointegration in cementless THA.