Hartwig Michael Künzel

Prof. Dr. Hartwig Michael Künzel

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
HKHartwig Michael Künzel
Hartwig Michael Künzel
DZDaniel Zirkelbach
Daniel Zirkelbach
Moisture control design of building envelope components by hygrothermal simulation is state-of-the-art today. For architects and engineers, there are several simulation tools available which comply with the European Standard EN 15026 and/or the North-American moisture control standard ANSI/ASHRAE 160. Numerous investigations have shown that hygrothermal simulation models are clearly superior to steady-state dew-point calculations in predicting the climate dependent moisture behaviour of construction assemblies. However, compared to real life, there remains a major deficit: most models assume a perfectly assembled and installed building component without any cracks or gaps that may cause unintended moisture entry. This draw-back has been recognized and new approaches have been developed to allow for imperfections by introducing source terms in the models, e.g. accounting for the effects of rainwater penetration. The magnitude of these moisture sources is still a matter of discussion because they should represent best practice situations and not poor workmanship. This paper gives an example of a simplified approach to consider rainwater leakage in one-dimensional hygrothermal building component simulation.

22 June 2022 in Indoor Air
Verified
Journal Article
Open access
TSTunga Salthammer
Tunga Salthammer
JZJiangyue Zhao
Jiangyue Zhao
ASAlexandra Schieweck
Alexandra Schieweck
EUErik Uhde
Erik Uhde
THTareq Hussein
Tareq Hussein
WBWolfram Birmili
Wolfram Birmili
The IPCC 2021 report predicts rising global temperatures and more frequent extreme weather events in the future, which will have different effects on the regional climate and concentrations of ambient air pollutants. Consequently, changes in heat and mass transfer between the inside and outside of buildings will also have an increasing impact on indoor air quality. It is therefore surprising that indoor spaces and occupant well-being still play a subordinate role in the studies of climate change. To increase awareness for this topic, the Indoor Air Quality Climate Change (IAQCC) model system was developed, which allows short and long-term predictions of the indoor climate with respect to outdoor conditions. The IAQCC is a holistic model that combines different scenarios in the form of submodels: building physics, indoor emissions, chemical-physical reaction and transformation, mold growth, and indoor exposure. IAQCC allows simulation of indoor gas and particle concentrations with outdoor influences, indoor materials and activity emissions, particle deposition and coagulation, gas reactions, and SVOC partitioning. These key processes are fundamentally linked to temperature and relative humidity. With the aid of the building physics model, the indoor temperature and humidity, and pollutant transport in building zones can be simulated. The exposure model refers to the calculated concentrations and provides evaluations of indoor thermal comfort and exposure to gaseous, particulate, and microbial pollutants.

6 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
SKSughwan Kim
Sughwan Kim
DZDaniel Zirkelbach
Daniel Zirkelbach
HKHartwig Michael Künzel
Hartwig Michael Künzel
Hygrothermal simulations have become essential for sustainable and resilient building design because moisture is the major cause of problems in buildings. Appropriate meteorological input data are important to obtain meaningful simulation results. Therefore, this article reviews different methods to create Hygrothermal Reference Years (HRY) as severe or average climate inputs. The current standards define HRYs solely based on outdoor temperature, although moisture problems are caused by a combination of climate parameters, including driving rain and other loads. Therefore, there are also methods considering several impact parameters. The existing methods can be classified into two categories: construction-independent and construction-dependent methods. The former determines HRY based on a weather data analysis and is useful for large-scale parametric studies comprising many climatic parameters acting on buildings. The latter is based in addition to computer simulations to verify the HRY also in the context of specific construction types. It is a more comprehensive approach since the moisture responses of constructions are the decisive outcome for performance predictions. The advantages and disadvantages of the different methods are summarized and compared. Lastly, further research questions and simplifications aimed at practitioners are pointed out to arrive at reliable hygrothermal building performance predictions.

22 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
TOToba Olaoye
Toba Olaoye
MDMark Dewsbury
Mark Dewsbury
HKHartwig Michael Künzel
Hartwig Michael Künzel
Hygrothermal assessment is essential to the production of healthy and energy efficient buildings. This has given rise to the demand for the development of a hygrothermal laboratory, as input data to hygrothermal modeling tools can only be sourced and validated through appropriate empirical measurements in a laboratory. These data are then used to quantify a building’s dynamic characteristic moisture transport vis-a-vis a much more comprehensive energy performance analysis through simulation. This paper discusses the methods used to establish Australia’s first hygrothermal laboratory for testing the water vapor resistivity properties of construction materials. The approach included establishing a climatically controlled hygrothermal test room with an automatic integrated system which controls heating, cooling, humidifying, and de-humidifying as required. The data acquisition for this hygrothermal test room operates with the installation of environmental sensors connected to specific and responsive programming codes. The room was successfully controlled to deliver a relative humidity of 50% with ±1%RH deviation and at 23 °C temperature with ±1 °C fluctuation during the testing of the water vapor diffusion properties of a pliable membrane common in Australian residential construction. To validate the potential of this testing facility, an independent measurement was also conducted at the Fraunhofer Institute of Building Physics laboratory (IBP) Holzkirchen, Germany for the diffusion properties of the same pliable membrane. The inter-laboratory testing results were subjected to statistical analysis of variance, this indicates that there is no significant difference between the result obtained in both laboratories. In conclusion, this paper demonstrates that a low-cost hygrothermally controlled test room can successfully replace the more expensive climatic chamber.

25 October 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
SNShruti Nath
Shruti Nath
MDMark Dewsbury
Mark Dewsbury
HKHartwig Michael Künzel
Hartwig Michael Künzel
PWPhillipa Watson
Phillipa Watson
To reduce greenhouse gas emissions, nations have introduced energy efficiency regulations for new and existing buildings. This has been considered advantageous as more efficient building envelopes would reduce energy consumed to heat and cool home interiors to within accepted thermal comfort bandwidths. However, as these methods have been adopted, many nations have identified an unintended visible presence of surface and interstitial condensation and mould in new code-compliant buildings. In Australia, it has been estimated that up to 50% of Australian houses constructed in the last decade (2006–2016) have a presence of condensation and mould. Australia introduced its first condensation and mould-related building regulations for new homes in 2019. This paper reports on the hygrothermal and mould growth analysis of the most common low-rise residential external wall system, a timber-framed clay masonry veneer wall. A key component of this paper discusses the application of innovative methods in the Australian context. The external wall’s moisture accumulation and mould growth were simulated for a period of ten years using the transient hygrothermal simulation tool, WUFI® Pro, and the mould growth model, WUFI® VTT. This study identified significant risks for this typical external wall system when constructed in a temperate climate.

5 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
TOToba Olaoye
Toba Olaoye
MDMark Dewsbury
Mark Dewsbury
HKHartwig Michael Künzel
Hartwig Michael Künzel
Hygrothermal modelling is increasingly used to inform building envelope design. A key input for these calculations is the material’s vapour diffusion properties. Respecting a growing international concern, this research has questioned the appropriateness of the current test method to establish construction material for vapour diffusion properties. This article reports on the empirical measurement of the vapour diffusion properties of two vapour-permeable building membranes commonly used in Australia residential systems when subjected to variable relative humidity conditions. The method involved completing dry cup and wet cup standard tests as specified in ISO 12572, (23 °C and 50% relative humidity RH). Further tests were then conducted as temperature remained at 23 °C but the relative humidity changed to 35%, 65% and 80%, respectively, in order to know if the diffusion properties are the same or change with varying relative humidity. The results from the wet cup and dry cup tests under different relative humidity conditions were non-linear and different. These results indicate vapour-permeable membranes behave differently when exposed to different relative humidity conditions. In conclusion, this research demonstrates that the current vapour resistivity test method is inadequate, hence the need to establish more detailed diffusion resistivity properties in different humidity ranges that represent conditions experienced within a building’s external envelope.