Francesco Pelella

Dr. Francesco Pelella

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
GLGianluca Lillo
Gianluca Lillo
RMR. Mastrullo
R. Mastrullo
AMA.W. Mauro
A.W. Mauro
FPFrancesco Pelella
Francesco Pelella
Luca ViscitoLuca Viscito
Luca Viscito

1 November 2020 in International Journal of Refrigeration
Verified
Journal Article
Closed access
AMAlfonso William Mauro
Alfonso William Mauro
GNG. Napoli
G. Napoli
FPFrancesco Pelella
Francesco Pelella
Luca ViscitoLuca Viscito
Luca Viscito

19 July 2025 in Applied Thermal Engineering
Verified
Journal Article
Open access
FPFrancesco Pelella
Francesco Pelella
LVLuca Viscito
Luca Viscito
GNGiovanni Napoli
Giovanni Napoli
FTFrancesco Tariello
Francesco Tariello
Antonio PantaleoAntonio Pantaleo
Antonio Pantaleo
AMAlfonso William Mauro
Alfonso William Mauro

23 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
FPFrancesco Pelella
Francesco Pelella
APAdelso Flaviano Passarelli
Adelso Flaviano Passarelli
BLBelén Llopis-Mengual
Belén Llopis-Mengual
Luca ViscitoLuca Viscito
Luca Viscito
ENEmilio Navarro-Peris
Emilio Navarro-Peris
AMAlfonso William Mauro
Alfonso William Mauro
The European Union’s 2050 targets for decarbonization and electrification are promoting the widespread integration of heat pumps for space heating, cooling, and domestic hot water in buildings. However, their energy and environmental performance can be significantly compromised by soft faults, such as refrigerant leakage or heat exchanger fouling, which may reduce system efficiency by up to 25%, even with maintenance intervals every two years. As a result, the implementation of self-fault detection, diagnosis, and evaluation (FDDE) tools based on operational data has become increasingly important. The complexity and added value of these tools grow as they progress from simple fault detection to quantitative fault evaluation, enabling more accurate and timely maintenance strategies. Direct fault measurements are often unfeasible due to spatial, economic, or intrusiveness constraints, thus requiring indirect methods based on low-cost and accessible measurements. In such cases, overlapping fault symptoms may create diagnostic ambiguities. Moreover, the accuracy of FDDE approaches depends on the type and number of sensors deployed, which must be balanced against cost considerations. This paper provides a comprehensive review of current FDDE methodologies for heat pumps, drawing insights from the academic literature, patent databases, and commercial products. Finally, the role of artificial intelligence in enhancing fault evaluation capabilities is discussed, along with emerging challenges and future research directions.

30 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
FPFrancesco Pelella
Francesco Pelella
Luca ViscitoLuca Viscito
Luca Viscito
FMFederico Magnea
Federico Magnea
AZAlessandro ZANELLA
Alessandro ZANELLA
Stanislao PatalanoStanislao Patalano
Stanislao Patalano
Nicola BiancoNicola Bianco
Nicola Bianco
The automotive production sector plays a significant role in the energy consumption of all the industrial sphere, which currently represents approximately 38% of the total global energy use. Especially in production sites with several manufacturing lines working in parallel, the occurrence of failures and anomalies or sudden changes in the production volume may require a re-scheduling of the entire production process. In this regard, a digital twin of each phase of the process would give several indications about the new re-scheduled manufacture in terms of energy consumption and the control strategy to adopt. Therefore, the main goal of this paper is to propose different modeling approaches to a degreasing tank process, which is a preliminary phase at automotive production sites before the application of paint to car bodies. In detail, two different approaches have been developed: the first is a physics-based thermodynamic approach, which relies on the mass and energy balances of the system analyzed, and the second is machine learning-based, with the calibration of several artificial neural networks (ANNs). All the investigated approaches were assessed and compared, and it was determined that, for this application and with the data at our disposal, the thermodynamic approach has better prediction accuracy, with an overall mean absolute error (MAE) of 1.30 °C. Moreover, the model can be used to optimize the heat source policy of the tank, for which it has demonstrated, with historical data, an energy saving potentiality of up to 30%, and to simulate future scenarios in which, due to company constraints, a re-scheduling of the production of more work shifts is required.

5 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
Luca ViscitoLuca Viscito
Luca Viscito
FPFrancesco Pelella
Francesco Pelella
Andrea RegaAndrea Rega
Andrea Rega
FMFederico Magnea
Federico Magnea
Gerardo Maria MauroGerardo Maria Mauro
Gerardo Maria Mauro
Nicola BiancoNicola Bianco
Nicola Bianco
A meticulous thermo-hygrometric control is essential for various industrial production processes, particularly those involving the painting phases of body-in-white, in which the air temperature and relative humidity in production boots must be limited in strict intervals to ensure the high quality of the final product. However, traditional proportional integrative derivative (PID) controllers may result in non-optimal control strategies, leading to energy wastage due to response delays and unnecessary superheatings. In this regard, predictive models designed for control can significantly aid in achieving all the targets set by the European Union. This paper focuses on the development of a predictive model for the energy consumption of an air handling unit (AHU) used in the paint-shop area of an automotive production process. The model, developed in MATLAB 2024b, is based on mass and energy balances within each component, and phenomenological equations for heat exchangers. It enables the evaluation of thermal powers and water mass flow rates required to process an inlet air flow rate to achieve a target condition for the temperature and relative humidity. The model was calibrated and validated using experimental data of a real case study of an automotive production process, obtaining mean errors of 16% and 31% for the hot and cold heat exchangers, respectively, in predicting the water mass flow rate. Additionally, a control logic based on six regulation thermo-hygrometric zones was developed, which depended on the external conditions of temperature and relative humidity. Finally, as the main outcome, several examples are provided to demonstrate both the applicability of the developed model and its potential in optimizing energy consumption, achieving energy savings of up to 46% compared to the actual baseline control strategy, and external boundary conditions, identifying an optimal trade-off between energy saving and operation feasibility.