Kamrul Islam

Dr. Kamrul Islam

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
KIKamrul Islam
Kamrul Islam
SDSamar Damiati
Samar Damiati
JSJagriti Sethi
Jagriti Sethi
ASAhmed Suhail
Ahmed Suhail
GPGenhua Pan
Genhua Pan
Clusterin (CLU) has been associated with the clinical progression of Alzheimer’s disease (AD) and described as a potential AD biomarker in blood plasma. Due to the enormous attention given to cerebrospinal fluid (CSF) biomarkers for the past couple of decades, recently found blood-based AD biomarkers like CLU have not yet been reported for biosensors. Herein, we report the electrochemical detection of CLU for the first time using a screen-printed carbon electrode (SPCE) modified with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) and decorated with specific anti-CLU antibody fragments. This bifunctional linker molecule contains succinylimide ester to bind protein at one end while its pyrene moiety attaches to the carbon surface by means of π-π stacking. Cyclic voltammetric and square wave voltammetric studies showed the limit of detection down to 1 pg/mL and a linear concentration range of 1–100 pg/mL with good sensitivity. Detection of CLU in spiked human plasma was demonstrated with satisfactory recovery percentages to that of the calibration data. The proposed method facilitates the cost-effective and viable production of label-free point-of-care devices for the clinical diagnosis of AD.

12 July 2017 in Biosensors
Verified
Journal Article
Open access
PDF file
KIKamrul Islam
Kamrul Islam
ASAhmed Suhail
Ahmed Suhail
GPGenhua Pan
Genhua Pan
We report on a label-free immunosensor based on graphene field effect transistors (G-FETs) for the ultrasensitive detection of Human Chorionic Gonadotrophin (hCG), as an indicator of pregnancy and related disorders, such as actopic pregnancy, choriocarcinoma and orchic teratoma. Pyrene based bioactive ester was non-covalently anchored onto the graphene channel in order to retain the sp2 lattice. The G-FET transfer characteristics showed repeatable and reliable responses in all surface modifying steps using a direct current (DC) readout system. The hCG concentration gradient showed a detection limit of ~1 pg·mL−1. The proposed method facilitates the cost-effective and viable production of graphene point-of-care devices for clinical diagnosis.

5 February 2010 in ECS Meeting Abstracts
Verified
Journal Article
Open access
JGJewel A. Gomes
Jewel A. Gomes
KIKamrul Islam
Kamrul Islam
IHIftikher Haider
Iftikher Haider
GIGeorge Irwin
George Irwin
PBPaul Bernazzani
Paul Bernazzani
DCDavid Cocke
David Cocke