Venkat Ayyalasomayajula

Dr. Venkat Ayyalasomayajula


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
VAVenkat Ayyalasomayajula
Venkat Ayyalasomayajula
BPBaptiste Pierrat
Baptiste Pierrat
PBPierre Badel
Pierre Badel
Abdominal aortic aneurysm is a prevalent cardiovascular disease with high mortality rates. The mechanical response of the arterial wall relies on the organizational and structural behavior of its microstructural components, and thus, a detailed understanding of the microscopic mechanical response of the arterial wall layers at loads ranging up to rupture is necessary to improve diagnostic techniques and possibly treatments. Following the common notion that adventitia is the ultimate barrier at loads close to rupture, in the present study, a finite element model of adventitial collagen network was developed to study the mechanical state at the fiber level under uniaxial loading. Image stacks of the rabbit carotid adventitial tissue at rest and under uniaxial tension obtained using multi-photon microscopy were used in this study, as well as the force–displacement curves obtained from previously published experiments. Morphological parameters like fiber orientation distribution, waviness, and volume fraction were extracted for one sample from the confocal image stacks. An inverse random sampling approach combined with a random walk algorithm was employed to reconstruct the collagen network for numerical simulation. The model was then verified using experimental stress–stretch curves. The model shows the remarkable capacity of collagen fibers to uncrimp and reorient in the loading direction. These results further show that at high stretches, collagen network behaves in a highly non-affine manner, which was quantified for each sample. A comprehensive parameter study to understand the relationship between structural parameters and their influence on mechanical behavior is presented. Through this study, the model was used to conclude important structure–function relationships that control the mechanical response. Our results also show that at loads close to rupture, the probability of failure occurring at the fiber level is up to 2%. Uncertainties in usually employed rupture risk indicators and the stochastic nature of the event of rupture combined with limited knowledge on the microscopic determinants motivate the development of such an analysis. Moreover, this study will advance the study of coupling microscopic mechanisms to rupture of the artery as a whole.

7 February 2025 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
LRLotte Rijken
Lotte Rijken
SZSabrina Zwetsloot
Sabrina Zwetsloot
SSStefan Smorenburg
Stefan Smorenburg
JWJelmer Wolterink
Jelmer Wolterink
IIIvana Išgum
Ivana Išgum
KYKak Khee Yeung
Kak Khee Yeung
Introduction: Abdominal aortic aneurysms (AAAs) and peripheral artery disease (PAD) are two vascular diseases with a significant risk of major adverse cardiovascular events and mortality. A challenge in current disease management is the unpredictable disease progression in individual patients. The VASCUL-AID-RETRO study aims to develop trustworthy multimodal predictive artificial intelligence (AI) models for multiple tasks including risk stratification of disease progression and cardiovascular events in patients with AAA and PAD. Methods: The VASCUL-AID-RETRO study will collect data from 5000 AAA and 6000 PAD patients across multiple European centers of the VASCUL-AID consortium using electronic health records from 2015 to 2024. This retrospectively-collected data will be enriched with additional data from existing biobanks and registries. Multimodal data, including clinical records, radiological imaging, proteomics, and genomics, will be collected to develop AI models predicting disease progression and cardiovascular risks. This will be done while integrating the international ethics guidelines and legal standards for trustworthy AI, to ensure a socially-responsible data integration and analysis. Proposed Analyses: A consensus-based variable list of clinical parameters and core outcome set for both diseases will be developed through meetings with key opinion leaders. Blood, plasma, and tissue samples from existing biobanks will be analyzed for proteomic and genomic variations. AI models will be trained on segmented AAA and PAD artery geometries for estimation of hemodynamic parameters to quantify disease progression. Initially, risk prediction models will be developed for each modality separately, and subsequently, all data will be combined to be used as input to multimodal prediction models. During all processes, data security, data quality, and ethical guidelines and legal standards will be carefully considered. As a next step, the developed models will be further adjusted with prospective data and internally validated in a prospective cohort (VASCUL-AID-PRO study). Conclusion: The VASCUL-AID-RETRO study will utilize advanced AI techniques and integrate clinical, imaging, and multi-omics data to predict AAA and PAD progression and cardiovascular events. Clinical Trial Registration: The VASCUL-AID-RETRO study is registered at www.clinicaltrials.gov under the identification number NCT06206369. Clinical Impact: The VASCUL-AID-RETRO study aims to improve clinical practice of vascular surgery by developing artificial intelligence-driven multimodal predictive models for patients with abdominal aortic aneurysms or peripheral artery disease, enhancing personalized medicine. By integrating comprehensive data sets including clinical, imaging, and multi-omics data, these models have the potential to provide accurate risk stratification for disease progression and cardiovascular events. An innovation lies in the extensive European data set in combination with multimodal analyses approaches, which enables the development of advanced models to facilitate better understanding of disease mechanisms and progression. For clinicians, this means that more precise, individualized treatment plans can be established, ultimately aiming to improve patient outcomes.

9 January 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
VAVenkat Ayyalasomayajula
Venkat Ayyalasomayajula
ØEØyvind Ervik
Øyvind Ervik
HSHanne Sorger
Hanne Sorger
BSBjørn Skallerud
Bjørn Skallerud
Mechanical characterization of hydrogels and ultra-soft tissues is a challenging task both from an experimental and material parameter estimation perspective because they are much softer than many biological materials, ceramics, or polymers. The elastic modulus of such materials is within the 1 - 100 kPa range, behaving as a hyperelastic solid with strain hardening capability at large strains. In the current study, indentation experiments have been performed on agarose hydrogels, bovine liver, and bovine lymph node specimens. This work reports on the reliable determination of the elastic modulus by indentation experiments carried out at the macro-scale (mm) using a spherical indenter. However, parameter identification of the hyperelastic material properties usually requires an inverse finite element analysis due to the lack of an analytical contact model of the indentation test. Hence a comprehensive study on the spherical indentation of hyperelastic soft materials is carried out through robust computational analysis. Neo-Hookean and first-order Ogden hyperelastic material models were found to be most suitable. A case study on known anisotropic hyperelastic material showed the inability of the inverse finite element method to uniquely identify the whole material parameter set.

14 July 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
VAVenkat Ayyalasomayajula
Venkat Ayyalasomayajula
BSBjørn Skallerud
Bjørn Skallerud
The trachea is a complex tissue made up of hyaline cartilage, fibrous tissue, and muscle fibers. Currently, the knowledge of microscopic structural organization of these components and their role in determining the tissue's mechanical response is very limited. The purpose of this study is to provide data on the microstructure of the tracheal components and its influence on tissue's mechanical response. Five bovine tracheae were used in this study. Adventitia, cartilage, mucosa/submucosa, and trachealis muscle layers were methodically cut out from the whole tissue. Second-harmonic generation(SHG) via multi-photon microscopy (MPM) enabled imaging of collagen fibers and muscle fibers. Simultaneously, a planar biaxial test rig was used to record the mechanical behavior of each layer. In total 60 samples were tested and analyzed. Fiber architecture in the adventitia and mucosa/submucosa layer showed high degree of anisotropy with the mean fiber angle varying from sample to sample. The trachealis muscle displayed neat layers of fibers organized in the longitudinal direction. The cartilage also displayed a structure of thick mesh-work of collagen type II organized predominantly towards the circumferential direction. Further, mechanical testing demonstrated the anisotropic nature of the tissue components. The cartilage was identified as the stiffest component for strain level < 20% and hence the primary load bearing component. The other three layers displayed a non-linear mechanical response which could be explained by the structure and organization of their fibers. This study is useful in enhancing the utilization of structurally motivated material models for predicting tracheal overall mechanical response.

7 July 2023 in Journal of Biomechanics
Verified
Journal Article
Open access
VAVenkat Ayyalasomayajula
Venkat Ayyalasomayajula
BPBaptiste Pierrat
Baptiste Pierrat
PBPierre Badel
Pierre Badel
So far, the prevalent rupture risk quantification of aortic aneurysms does not consider information of the underlying microscopic mechanisms. Uniaxial tension tests were performed on imaged aorta samples oriented in circumferential and longitudinal directions. To account for local heterogeneity in collagen fiber architecture, SHG imaging was performed on tissues at several locations prior to mechanical testing. This enabled the quantification of micro-scale information including organization of collagen fibers using relevant probability density functions. Two different modeling approaches are presented in this study for the sake of comparison. A multi-scale mechanical model was developed using this micro-structural information with collagen fibers as main components. accounting for non-affine fiber kinematics. Simultaneously, an embedded element model that accounts for affine fiber kinematics was developed in Abaqus using the same micro-structural information. Numerical simulations emulating uniaxial tension experiments were performed on the developed models. Global mechanical response of both models agreed well with the experimental data, although leading to mismatched material properties. The models present a rudimentary yet better than before representation of structure based description of aortic-tissue failure mechanics. reinforcing the importance of structural organization of micro-scale constituents and their kinematics in determining tissue failure.

24 June 2022 in Mechanics of Soft Materials
Verified
Journal Article
Open access
PDF file
VAVenkat Ayyalasomayajula
Venkat Ayyalasomayajula
BPBaptiste Pierrat
Baptiste Pierrat
PBPierre Badel
Pierre Badel
The decision of surgical intervention for an aortic aneurysm is usually associated with an assessment of risk of its rupture. Global rupture risk assessment parameters like wall diameter and growth of the aneurysm over time often fail at predicting the risk of rupture with accuracy. This paper will investigate the hypothesis that the tissue’s microstructure determines its macroscopic failure. To this aim, two different testing protocols have been implemented. Human ascending thoracic aortic aneurysm (ATAA) tissue samples were subjected to bulge-inflation testing until rupture coupled with multi-photon microscopy (MPM) imaging. Image stacks of the sample were acquired at different pressure levels. Additionally, porcine aorta samples were tested under uniaxial tension until failure and their response was recorded. Prior to mechanical testing, MPM image stacks were acquired at four different zones on the sample. The image stacks acquired at the load free state were used to extract morphological information relating to collagen fibers. Then, an inverse random sampling approach was used to generate pseudomorphological parameters for network reconstruction. A discrete model of the collagen network signifying its stochastic nature was then developed, including both prefailure and post-failure mechanics. The model was able to replicate the mechanical response and failure of the tissue, and demonstrated that fiber-based damage can strongly shape the macroscopic failure response of the tissue. Identified values of collagen fiber failure strain were in the range of 8.8 to 29.3% in the case of aneurysmal samples, and 18.7 to 25.5% in the case of porcine samples. A statistical analysis enabled the characterization of correlation between fiber morphology and tissue failure. The model may serve as a useful tool for predicting macroscale failure of the aortic wall based on the variations in microscale morphology.