In ancient villages, the spread of uninterrupted fires caused great damage to clustered wooden houses. Thus, the spread of fire among wooden houses should be systematically studied to explore its characteristics. Statistical analysis is a feasible way to study the characteristics and underlying mechanisms of fire in full-scale wooden houses. In this study, 4 full-scale wooden buildings were built in an ethnic village in Guizhou Province, and the fire spread test was conducted by igniting a 0.63-MW power wood crib. To investigate the fire spread, the visual characteristics were observed, and the temperatures and heat radiation at special locations were monitored with thermocouples and radiation flowmeters, respectively. The effect of relative slope, heat radiation, and wind direction on fire spread characteristics was established by mathematical statistics, and the measured temperatures were used to verify the statistics’ regularity. The results showed that in wooden houses, fire spread was mainly influenced by the slope, the distance between houses, and wind direction. When the inner wall of a wooden house is protected by a fireproof coating, the thermal radiation spread and fire spread are both slower. The slope and distance had the same influence weight (0.41) on fire spread; however, since they affect the process in different ways, they should be analyzed separately for fire risk evaluation. The findings of this study provide a theoretical foundation for understanding the fire spread process in wooden buildings.
The biofilms generated in a fire extinguishing water supply system can cause corrosion and a reduction in the water supply capacity; thus, degrading the system performance. To mitigate microbial corrosion, appropriate disinfection measures are necessary. In this study, the secondary addition of chlorine is employed to investigate the kinetics of chlorine decay, and shock disinfection is applied to investigate the removal efficiency of corrosion bacteria, and the microbial composition of a biofilm on the pipe wall was also clarified. The results show that the residual chlorine content in the secondary chlorination process was directly correlated with the decay rate of residual chlorine and the corrosion rate of the pipe wall. Additionally, the chlorine impact disinfection method could reduce the electrochemical corrosion phenomenon of the pipe wall. When the concentration of chlorine was 3 mg/L, the removal rate of corrosion bacteria was higher in 60 min than in 30 min. Specifically, most of the bacteria were inactivated in 60 min and the biofilm was severely damaged. Shock disinfection could significantly inactivate all microflora in the biofilm; the relative abundances of microflora varied significantly, while the change of microflora at the phylum level was insignificant. This study can provide theoretical support for the secondary addition of chlorine and shock disinfection in a fire extinguishing water supply system.
In order to study the characteristics of the thermal runaway process of a full-size prefabricated cabin energy storage system, a full-scale prefabricated cabin energy storage physical fire test platform was designed, using 100% SOC energy storage battery packs as the thermal runaway object, and conducts full-scale prefabricated cabin energy storage system physical fire experiments. The experiment analyzes the early change rules of parameters such as temperature, voltage, CO, and VOC after the energy storage system thermal runaway, and explores the technical methods to improve the fire protection of electrochemical energy storage systems. The results show that the time when the surface temperature of the runaway cell undergoes a sudden change is 37 seconds later than the time when the voltage undergoes a sudden change; the CO at the bottom and middle of the runaway cluster reaches the alarm threshold 25 seconds and 39 seconds earlier than that at the top of the cluster, respectively, and the peak concentration of CO at the bottom and middle of the cluster is more than three times that at the top of the cluster. The opening of the fan will cause the CO concentration on the left side of the thermal runaway cluster to be higher than that of the runaway cluster; before the battery thermal runaway, the VOC concentration at the middle and top of the runaway cluster is generally higher than that at the bottom of the cluster. After the thermal runaway occurs, the VOC concentration at the bottom of the thermal runaway cluster exceeds that at other positions of the runaway cluster and the adjacent cluster; the tVOC at the top, middle, and bottom of the thermal runaway cluster is 2296 seconds, 1681 seconds, and 1464 seconds earlier than the tCO, respectively, but the initial detection value of VOC fluctuates more than that of CO.
In order to study the characteristics of the thermal runaway process of a full-size prefabricated cabin energy storage system, a full-scale prefabricated cabin energy storage physical fire test platform was designed using 100% SOC energy storage battery packs as the thermal runaway object, and full-scale prefabricated cabin energy storage system physical fire experiments were conducted. This experiment analyzes the early change rules of parameters such as temperature, voltage, CO, and VOC after the energy storage system enters thermal runaway and explores the technical methods to improve the fire protection of electrochemical energy storage systems. The results show that the time when the surface temperature of the runaway cell undergoes a sudden change is 37 s later than the time when the voltage undergoes a sudden change; the CO at the bottom and middle of the runaway cluster reaches the alarm threshold 25 s and 39 s earlier than that at the top of the cluster, respectively, and the peak concentration of CO at the bottom and middle of the cluster is more than three times that at the top of the cluster. The opening of the fan causes the CO concentration on the left side of the thermal runaway cluster to be higher than that of the runaway cluster; before the battery thermal runaway, the VOC concentration at the middle and top of the runaway cluster is generally higher than that at the bottom of the cluster. After thermal runaway occurs, the VOC concentration at the bottom of the thermal runaway cluster exceeds that at other positions of the runaway cluster and the adjacent cluster; the tVOC at the top, middle, and bottom of the thermal runaway cluster is 2296 s, 1681 s, and 1464 s earlier than the tCO, respectively, but the initial detection value of VOC fluctuates more than that of CO.