Manni Mo

Manni Mo

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
MMManni Mo
Manni Mo
YYYunze Yang
Yunze Yang
FZFenni Zhang
Fenni Zhang
WJWENWEN JING
WENWEN JING
RIRafael Iriya
Rafael Iriya
NTNongjian Tao
Nongjian Tao

28 April 2021 in Analytical Chemistry
Verified
Journal Article
Closed access
FZFenni Zhang
Fenni Zhang
JJJiapei Jiang
Jiapei Jiang
MMMichelle McBride
Michelle McBride
XZXinyu Zhou
Xinyu Zhou
YYYunze Yang
Yunze Yang
Shaopeng WangShaopeng Wang
Shaopeng Wang

5 August 2022 in ACS Sensors
Verified
Journal Article
Closed access
FZFenni Zhang
Fenni Zhang
MMManni Mo
Manni Mo
JJJiapei Jiang
Jiapei Jiang
XZXinyu Zhou
Xinyu Zhou
MMMichelle McBride
Michelle McBride
Shaopeng WangShaopeng Wang
Shaopeng Wang

5 February 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
RIRafael Iriya
Rafael Iriya
BBBrandyn Braswell
Brandyn Braswell
MMManni Mo
Manni Mo
FZFenni Zhang
Fenni Zhang
SHShelley Haydel
Shelley Haydel
Shaopeng WangShaopeng Wang
Shaopeng Wang
Bacterial infections, increasingly resistant to common antibiotics, pose a global health challenge. Traditional diagnostics often depend on slow cell culturing, leading to empirical treatments that accelerate antibiotic resistance. We present a novel large-volume microscopy (LVM) system for rapid, point-of-care bacterial detection. This system, using low magnification (1–2×), visualizes sufficient sample volumes, eliminating the need for culture-based enrichment. Employing deep neural networks, our model demonstrates superior accuracy in detecting uropathogenic Escherichia coli compared to traditional machine learning methods. Future endeavors will focus on enriching our datasets with mixed samples and a broader spectrum of uropathogens, aiming to extend the applicability of our model to clinical samples.

27 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MMManni Mo
Manni Mo
BFBo Fu
Bo Fu
PHPiyush Hota
Piyush Hota
PCPinar Cay-Durgun
Pinar Cay-Durgun
RWRan Wang
Ran Wang
EFErica Forzani
Erica Forzani
Colorimetric sensors are widely used because of their inherent advantages including accuracy, rapid response, ease-of-use, and low costs; however, they usually lack reusability, which precludes the continuous use of a single sensor. We have developed a threshold-responsive colorimetric system that enables repeated analyte measurements by a single colorimetric sensor. The threshold responsive algorithm automatically adjusts the sensor exposure time to the analyte and measurement frequency according to the sensor response. The system registers the colorimetric sensor signal change rate, prevents the colorimetric sensor from reaching saturation, and allows the sensor to fully regenerate before the next measurement is started. The system also addresses issues common to colorimetric sensors, including the response time and range of detection. We demonstrate the benefits and feasibility of this novel system, using colorimetric sensors for ammonia and carbon dioxide gases for continuous monitoring of up to (at least) 60 detection cycles without signs of analytical performance degradation of the sensors.

28 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
PHPiyush Hota
Piyush Hota
APAdithya Shyamala Pandian
Adithya Shyamala Pandian
Rodrigo Ezequiel DominguezRodrigo Ezequiel Dominguez
Rodrigo Ezequiel Dominguez
MMManni Mo
Manni Mo
BFBo Fu
Bo Fu
EFErica Forzani
Erica Forzani
Acute kidney injury (AKI) affects thousands of hospitalized patients annually, yet early detection remains challenging as serum creatinine elevation lags behind clinical deterioration. Decreased urine output (UO) represents a key diagnostic criterion of AKI, sometimes manifesting hours before biochemical changes; however, current manual monitoring methods are labor-intensive and prone to error. Here, we developed and validated a simple, cost-effective automated urine flow meter using non-contact optical sensors, a peristaltic pump, and microcontroller-based automation for precise, real-time monitoring of urine output in clinical settings, named P-meter. Three successive prototypes (V1, V2, V3) were validated against gold-standard gravimetric measurements over 285 h of testing during animal experiments that required bladder catheterization. Iterative refinement addressed miniaturization challenges, fluid dynamics optimization, and sensor positioning to achieve progressively improved accuracy. The optimized V3 prototype demonstrated further enhanced volumetric precision, stability, and flow accuracy with near-unity linearity vs. reference method (R2 = 0.9889), minimal bias (mean error −0.1 mL), and 94.18% agreement within confidence limits (n = 86), outperforming the initial V1 prototype (R2 = 0.9971, mean error −1.69 mL, n = 207) and intermediate V2 design (R2 = 0.9941, mean error 3.63 mL, n = 390), primarily in terms of reduced bias and improved agreement. The P-meter offers accurate urine output monitoring at a lower cost than commercial systems, facilitating its use in early AKI detection and thereby improving patient outcomes.