Piyush Hota

Mr. Piyush Hota

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MMManni Mo
Manni Mo
BFBo Fu
Bo Fu
PHPiyush Hota
Piyush Hota
PCPinar Cay-Durgun
Pinar Cay-Durgun
RWRan Wang
Ran Wang
EFErica Forzani
Erica Forzani
Colorimetric sensors are widely used because of their inherent advantages including accuracy, rapid response, ease-of-use, and low costs; however, they usually lack reusability, which precludes the continuous use of a single sensor. We have developed a threshold-responsive colorimetric system that enables repeated analyte measurements by a single colorimetric sensor. The threshold responsive algorithm automatically adjusts the sensor exposure time to the analyte and measurement frequency according to the sensor response. The system registers the colorimetric sensor signal change rate, prevents the colorimetric sensor from reaching saturation, and allows the sensor to fully regenerate before the next measurement is started. The system also addresses issues common to colorimetric sensors, including the response time and range of detection. We demonstrate the benefits and feasibility of this novel system, using colorimetric sensors for ammonia and carbon dioxide gases for continuous monitoring of up to (at least) 60 detection cycles without signs of analytical performance degradation of the sensors.

1 May 2021 in Respiratory Medicine
Verified
Journal Article
Closed access
KKKaram Abi Karam
Karam Abi Karam
PHPiyush Hota
Piyush Hota
SMS. Jimena Mora
S. Jimena Mora
ALAmelia Lowell
Amelia Lowell
KMKelly McKay
Kelly McKay
EFErica Forzani
Erica Forzani

8 June 2020
Verified
Conference Paper
Closed access
PHPiyush Hota
Piyush Hota
VWValana L. Wells
Valana L. Wells
An airborne, tethered, multi-rotor wind turbine, effectively a rotorcraft kite, provides one platform for accessing the energy in high altitude winds. The kite is maintained at altitude by its rotors operating in autorotation, and its equilibrium attitude and dynamic performance are affected by the aerodynamic rotor forces, which in turn are affected by the orientation and motion of the craft. The aerodynamic forces produced by such rotors can vary significantly depending on orientation, influencing the dynamics and stability of the system. This paper reviews the aerodynamic performance of an autorotating rotor through a range of angles of attack, and develops an aerodynamic model suitable for use in analysis of the dynamics, stability and design of a rotorcraft kite. The analysis utilizes a blade element model coupled with momentum theory for torque-free autorotation. The model uses a rigid-rotor assumption and is nominally limited to cases of small induced inflow angle and constant induced velocity. The model allows for linear twist. In order to validate the model, several rotors -- off-the-shelf model-aircraft propellers -- were tested in a low speed wind tunnel. Custom-built mounts allowed rotor angles of attack from 0 to 105 degrees in the test section, providing data for thrust, horizontal force, and angular velocity. Experimental results showed increasing thrust and angular velocity with rising pitch angles, whereas the in-plane horizontal force peaked and dropped after a certain value. The straightforward analytical results showed disagreement with the experimental trends especially at high pitch angles. The discrepancy was attributed to the rotor operating in turbulent wake and vortex ring states at high pitch angles, where momentum theory has proven to be invalid. However, adding a term for resisting torque to the model gives analytical results that show trends similar to the experimental values.

28 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
PHPiyush Hota
Piyush Hota
APAdithya Shyamala Pandian
Adithya Shyamala Pandian
Rodrigo Ezequiel DominguezRodrigo Ezequiel Dominguez
Rodrigo Ezequiel Dominguez
MMManni Mo
Manni Mo
BFBo Fu
Bo Fu
EFErica Forzani
Erica Forzani
Acute kidney injury (AKI) affects thousands of hospitalized patients annually, yet early detection remains challenging as serum creatinine elevation lags behind clinical deterioration. Decreased urine output (UO) represents a key diagnostic criterion of AKI, sometimes manifesting hours before biochemical changes; however, current manual monitoring methods are labor-intensive and prone to error. Here, we developed and validated a simple, cost-effective automated urine flow meter using non-contact optical sensors, a peristaltic pump, and microcontroller-based automation for precise, real-time monitoring of urine output in clinical settings, named P-meter. Three successive prototypes (V1, V2, V3) were validated against gold-standard gravimetric measurements over 285 h of testing during animal experiments that required bladder catheterization. Iterative refinement addressed miniaturization challenges, fluid dynamics optimization, and sensor positioning to achieve progressively improved accuracy. The optimized V3 prototype demonstrated further enhanced volumetric precision, stability, and flow accuracy with near-unity linearity vs. reference method (R2 = 0.9889), minimal bias (mean error −0.1 mL), and 94.18% agreement within confidence limits (n = 86), outperforming the initial V1 prototype (R2 = 0.9971, mean error −1.69 mL, n = 207) and intermediate V2 design (R2 = 0.9941, mean error 3.63 mL, n = 390), primarily in terms of reduced bias and improved agreement. The P-meter offers accurate urine output monitoring at a lower cost than commercial systems, facilitating its use in early AKI detection and thereby improving patient outcomes.

25 July 2026 in Translational Psychiatry
Verified
Journal Article
Open access
PDF file
KOKimberly C. Olney
Kimberly C. Olney
JBJ. Hudson Barnett
J. Hudson Barnett
LTLauren E. Tallant
Lauren E. Tallant
KGKatelin Gibson
Katelin Gibson
KTKennedi Todd
Kennedi Todd
JFJohn D. Fryer
John D. Fryer
Sepsis is a deadly syndrome arising from overactivation of the immune system in response to a pathogen. Severe sepsis can result in sepsis-associated encephalopathy (SAE) that significantly contributes to morbidity and long-term cognitive impairment. Studying the molecular underpinnings of SAE in the human brain is challenging, and rodent models have limited translational applicability due to significant neuroanatomical and immune differences. To bridge this gap, we employed a Yorkshire pig model to investigate changes in the brain cortex during the early stages of SAE using a uropathogenic strain of E. coli to model bacterial sepsis. Bulk RNAseq of cortical brain demonstrated profound global shifts in immune and inflammatory pathways, cytokine signaling, vascular dysfunction, and homeostatic dysregulation. To gain a more granular understanding of the changes in this model, we performed single-nucleus RNA sequencing (snRNAseq) on the same cortical brain tissue. This snRNAseq analysis revealed dramatic alterations in vascular cell populations, accompanied by concomitant glial cell activation. Surprisingly minimal changes were noted in neurons, likely due to the very early nature of this insult. The neurovascular unit, including vascular leptomeningeal cells (VLMCs), mural cells, endothelial cells, astrocytes, and microglia, showed strong upregulation of genes involved in TNF signaling, cellular responses to cytokine stimuli, and cytokine signaling in the immune system. Conversely, downregulated genes were enriched in pathways related to the disruption of metabolic and structural functions, including genes involved in maintaining the blood-brain barrier (BBB). Cell-cell communication analysis also identified significant rewiring of intercellular signaling in the septic brain, with an overall increase in the number and strength of cell to cell interactions in the E. coli pigs compared to saline controls. In saline controls, cell-cell communication was dominated by homeostatic signaling from microglia and astrocytes. In contrast, the septic pigs showed a significant shift toward inflammatory and immune-related signaling pathways, mainly involving microglia and astrocytes, along with the emergence of signaling pathways from mural cells and VLMCs. Our findings reveal that systemic sepsis triggers a rapid shift from homeostatic to inflammatory signaling within the neurovascular unit, driven by the emergence of pro-inflammatory crosstalk between vascular cells, astrocytes, and microglia. This porcine model effectively captures the acute transcriptional landscape of the septic brain, offering a critical window for therapeutic strategies aimed at stabilizing the BBB and preventing long-term cognitive decline in sepsis survivors.

31 July 2026 in Analytica
Verified
Journal Article
Open access
PDF file
Rodrigo Ezequiel DominguezRodrigo Ezequiel Dominguez
Rodrigo Ezequiel Dominguez
VYValerie Yang
Valerie Yang
AFAshley Fu
Ashley Fu
ECEdward H. Cheng
Edward H. Cheng
MTMirna Terrera
Mirna Terrera
EFErica Forzani
Erica Forzani
Urinary urea is a key biomarker for tracking protein oxidation and nitrogen balance. A persistent analytical limitation is that conventional total-nitrogen assays do not deconvolute urinary urea from urinary ammonia, and direct measurement still requires capital-intensive clinical analyzers. Here, we implement and independently validate two cost-effective methods that resolve urinary urea by pairing the presence and absence of urease: Method 1 is a urease-coupled potentiometric assay using an ammonium ion-selective electrode (ISE method); Method 2 is a microplate Berthelot–salicylate colorimetric assay employing a repurposed consumer-grade aquarium ammonia test kit (API®) (API method). Each method was validated against the Roche Cobas C311 clinical analyzer (ISE for urinary ammonia and API for urinary urea) in healthy adult volunteers (n = 10 each), and API–ISE were then compared head-to-head for urinary urea. ISE vs. Cobas yielded R2 = 0.967, slope 95% CI [0.867, 1.173], and Bland–Altman bias of −1.02 mM (95% LoA [−7.40, +5.36] mM). API vs. Cobas yielded R2 = 0.973, slope 95% CI [0.790, 1.039], and bias of −1.55 mM (95% LoA [−11.56, +8.46] mM). API–ISE urinary urea comparison confirmed mutual agreement (R2 = 0.9976, slope 95% CI [0.946, 1.024]; bias of +3.47 mM; 95% LoA [−14.60, +21.53] mM), with mean recoveries near 100% (API: 100.7 ± 2.9%; ISE: 100.6 ± 5.4%; 20–350 mM). Both methods agreed with the clinical analyzer, supporting their potential for decentralized, resource-limited testing; clinical and point-of-care validations are needed.