Muhammad Ali

Mr. Muhammad Ali

electronics and information convergence Eng, Kyung Hee University, Yongin, Gyeonggi-do, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


7 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Muhammad AliMuhammad Ali
Muhammad Ali
CCChamith Chandrarathna
Chamith Chandrarathna
SMSeong-Yeon Moon
Seong-Yeon Moon
MJMohammad Sami Jana
Mohammad Sami Jana
ASArooba Shafique
Arooba Shafique
JLJong-Wook Lee
Jong-Wook Lee
There are increasing demands for the Internet of Things (IoT), wearable electronics, and medical implants. Wearable devices provide various important daily applications by monitoring real-life human activities. They demand low-cost autonomous operation in a miniaturized form factor, which is challenging to realize using a rechargeable battery. One promising energy source is thermoelectric generators (TEGs), considered the only way to generate a small amount of electric power for the autonomous operation of wearable devices. In this work, we propose a compact and efficient converter system for energy harvesting from TEGs. The system consists of an 83.7% efficient boost converter and a 90 mV self-startup, sharing a single inductor. Innovated techniques are applied to adaptive maximum power point tracking (A-MPPT) and indirect zero current switching (I-ZCS) controllers for efficient operation. The startup circuit is realized using a gain-boosted tri-state buffer, which achieves 69.8% improved gain at the input VIN = 200 mV compared to the conventional approach. To extract the maximum power, we use an A-MPPT controller based on a simple capacitive divider, achieving 95.2% tracking efficiency. To address the challenge of realizing accurate voltage or current sensors, we propose an I-ZCS controller based on a new concept of maximum output voltage tracking (MOVT). The integrated circuit (IC) is fabricated using a 28 nm CMOS in a compact chip area of 0.03 mm2. The compact size, which has not been obtained with previous designs, is suitable for wearable device applications. Measured results show successful startup operation at an ultralow input, VIN = 90 mV. A peak conversion efficiency of 85.9% is achieved for the output of 1.07 mW.

22 May 2022
Verified
Conference Paper
Closed access
SCSeneke Chamith Chandrarathna
Seneke Chamith Chandrarathna
Muhammad AliMuhammad Ali
Muhammad Ali
SMSeong-Yoen Moon
Seong-Yoen Moon
JLJong-Wook Lee
Jong-Wook Lee
This paper presents a power management interface (PMI) IC for simultaneously harvesting energy from heterogeneous sources. The PMI-IC mainly consists of an active bias-flip rectifier (A-BFR) for AC sources, three input boost converters (3IBC) and a buck-boost converter for DC sources. We innovate a new adaptively-controlled, multi-impedance matching maximum power point tracking (AM-MPPT) controller by combining impedance matching and hill-climbing techniques to handle the power sources. The PMI-IC is fabricated in a 180 nm process with a 2 µm thick top-metal option. Six heterogeneous sources, including a battery, can simultaneously be utilized in the PMI-IC. The measured tracking efficiency is 98% when the input impedance RIN = 2 Ω, the peak efficiency is 92% at 1.7 mW of the output power (POUT). The typical input power range of the PMI-IC is 1.2 µW- 132 mW while regulating output VOUT1 at 1.8 V.

24 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XNXuan Tien Nguyen
Xuan Tien Nguyen
Muhammad AliMuhammad Ali
Muhammad Ali
JLJong-Wook Lee
Jong-Wook Lee
An active electrode (AE) and back-end (BE) integrated system for enhanced electrocardiogram (ECG)/electrode-tissue impedance (ETI) measurement is proposed. The AE consists of a balanced current driver and a preamplifier. To increase the output impedance, the current driver uses a matched current source and sink, which operates under negative feedback. To increase the linear input range, a new source degeneration method is proposed. The preamplifier is realized using a capacitively-coupled instrumentation amplifier (CCIA) with a ripple-reduction loop (RRL). Compared to the traditional Miller compensation, active frequency feedback compensation (AFFC) achieves bandwidth extension using the reduced size of the compensation capacitor. The BE performs three types of signal sensing: ECG, band power (BP), and impedance (IMP) data. The BP channel is used to detect the Q-, R-, and S-wave (QRS) complex in the ECG signal. The IMP channel measures the resistance and reactance of the electrode-tissue. The integrated circuits for the ECG/ETI system are realized in the 180 nm CMOS process and occupy a 1.26 mm2 area. The measured results show that the current driver supplies a relatively high current (>600 μApp) and achieves a high output impedance (1 MΩ at 500 kHz). The ETI system can detect resistance and capacitance in the ranges of 10 mΩ–3 kΩ and 100 nF–100 μF, respectively. The ECG/ETI system consumes 3.6 mW using a single 1.8 V supply.

2 February 2026 in Electricity
Verified
Journal Article
Open access
PDF file
ZHZeeshan Haider
Zeeshan Haider
SAShehzad Alamgir
Shehzad Alamgir
Muhammad AliMuhammad Ali
Muhammad Ali
SHS Jarjees Ul Hassan
S Jarjees Ul Hassan
ARIF MEHDIARIF MEHDI
ARIF MEHDI
The increasing integration of hybrid AC/DC networks in modern power systems introduces new challenges in fault detection and grounding scheme design, necessitating advanced techniques for stable and reliable operation. This paper investigates fault detection and grounding schemes in hybrid AC/DC networks using a machine learning (ML) approach to enhance accuracy, speed, and adaptability. Traditional methods often struggle with the dynamic and complex nature of hybrid systems, leading to delayed or incorrect fault identification. To address this, we propose a data-driven ML framework that leverages features such as voltage, current, and frequency characteristics for real-time detection and classification of faults. Additionally, the effectiveness of various grounding schemes is analyzed under different fault conditions to ensure system stability and safety. Simulation results on a hybrid AC/DC test network demonstrate the superior performance of the proposed ML-based fault detection method compared to conventional techniques, achieving high precision, recall, and robustness against noise and varying operating conditions. The findings highlight the potential of ML in improving fault management and grounding strategy optimization for future hybrid power grids.