Zeeshan Haider

Mr. Zeeshan Haider


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2026 in Electricity
Verified
Journal Article
Open access
PDF file
ZHZeeshan Haider
Zeeshan Haider
SAShehzad Alamgir
Shehzad Alamgir
Muhammad AliMuhammad Ali
Muhammad Ali
SHS Jarjees Ul Hassan
S Jarjees Ul Hassan
ARIF MEHDIARIF MEHDI
ARIF MEHDI
The increasing integration of hybrid AC/DC networks in modern power systems introduces new challenges in fault detection and grounding scheme design, necessitating advanced techniques for stable and reliable operation. This paper investigates fault detection and grounding schemes in hybrid AC/DC networks using a machine learning (ML) approach to enhance accuracy, speed, and adaptability. Traditional methods often struggle with the dynamic and complex nature of hybrid systems, leading to delayed or incorrect fault identification. To address this, we propose a data-driven ML framework that leverages features such as voltage, current, and frequency characteristics for real-time detection and classification of faults. Additionally, the effectiveness of various grounding schemes is analyzed under different fault conditions to ensure system stability and safety. Simulation results on a hybrid AC/DC test network demonstrate the superior performance of the proposed ML-based fault detection method compared to conventional techniques, achieving high precision, recall, and robustness against noise and varying operating conditions. The findings highlight the potential of ML in improving fault management and grounding strategy optimization for future hybrid power grids.

13 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
ARIF MEHDIARIF MEHDI
ARIF MEHDI
SHSyed Jarjees Ul Hassan
Syed Jarjees Ul Hassan
ZHZeeshan Haider
Zeeshan Haider
AKaa Ho-Young Kim
aa Ho-Young Kim
AHArif Hussain
Arif Hussain
There is a paradigm shift to hybrid (AC/DC) networks that integrate both AC and DC to meet growing energy demands, mitigate global warming, and interconnect distributed energy sources (DERs). However, the unique characteristics of AC/DC faults, the mutual interaction of hybrid lines, the harmonic components of converters/inverters, multiple directions of energy flow, and varying current levels have challenged the existing protection algorithms. Therefore, this paper presents a data-driven coordination AC/DC fault protection algorithm. The algorithm utilizes faulty voltage and current signals to retrieve the precise time-domain characteristics of AC, DC, and intersystem (IS) faults to develop the algorithm. The proposed algorithm consists of four stages: stage 1 includes the detection of faults, stage 2 identifies the fault as either AC or DC, stage 3 classifies the respective AC and DC faults, and stage 4 locates the AC/DC fault precisely. The hybrid test system is developed in a MATLAB/Simulink environment, and the data-driven algorithm is trained and tested in Python. The extensive simulation results for multiple fault cases, either AC or DC, and the comparisons of various performance indicators confirm the effectiveness of the developed algorithm, which performs efficiently under a noisy and extended hybrid AC/DC network. Compared to other schemes, the proposed coordination protection approach can enhance the speed and accuracy of hybrid AC/DC networks.

19 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZHZeeshan Haider
Zeeshan Haider
DKDaesoo Kim
Daesoo Kim
SYSoyoung Yang
Soyoung Yang
SLSungmin Lee
Sungmin Lee
Hyun-moon ParkHyun-moon Park
Hyun-moon Park
Sungbo ChoSungbo Cho
Sungbo Cho
Continuous blood pressure (BP) measurement is essential for real-time hypertension management and the prevention of related complications. To address this need, a cuffless BP estimation technique utilizing biosignals from wearable devices has gained significant attention. This study proposes a feasibility approach that integrates microneedle array electrodes (MNE) for ECG acquisition with photoplethysmogram (PPG) sensors for cuffless BP estimation. The algorithm employed is a baseline multivariate regression model using PTT and RR intervals, while the novelty lies in the hardware design aimed at improving signal quality and long-term wearability. The algorithm’s performance was validated using the Medical Information Mart for Intensive Care (MIMIC) database, achieving a mean error range of ±5.28 mmHg for the SBP and ±2.81 mmHg for the DBP. Additionally, the comparison with 253 measurements from three volunteers against an automated sphygmomanometer indicated an accuracy within ±25%. Therefore, these findings demonstrate the feasibility of an MNE-based ECG with PPG for BP integration for cuffless monitoring of SBP and DBP in daily life. The MIMIC-based evaluation was performed to verify the feasibility of the regression model under ideal public-database conditions. The volunteer experiment, performed with the developed MNE-ECG hardware, served as a separate preliminary feasibility test to observe hardware behavior in real-world measurements.

22 April 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
ZHZeeshan Haider
Zeeshan Haider
ARIF MEHDIARIF MEHDI
ARIF MEHDI
GSGwang-Su Shin
Gwang-Su Shin
SHS Jarjees Ul Hassan
S Jarjees Ul Hassan
CKChul-Hwan Kim
Chul-Hwan Kim