Katarzyna Matusiak

Dr. Katarzyna Matusiak

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
KMKatarzyna Matusiak
Katarzyna Matusiak
KBKatarzyna Berent
Katarzyna Berent
MMMarianna Ewa Marciszko-Wiąckowska
Marianna Ewa Marciszko-Wiąckowska
JCJ. Cieslak
J. Cieslak

26 November 2017 in Nanotoxicology
Verified
Journal Article
Closed access
KMKatarzyna Matusiak
Katarzyna Matusiak
ASAgnieszka Skoczen
Agnieszka Skoczen
ZSZuzanna Setkowicz
Zuzanna Setkowicz
AKAldona Kubala-Kukus
Aldona Kubala-Kukus
ISIlona Stabrawa
Ilona Stabrawa
Joanna ChwiejJoanna Chwiej
Joanna Chwiej
The main goal of this study was to evaluate in vivo effects of low dose of PEG-coated magnetic iron oxide nanoparticles (IONPs) on the rat liver. The IONPs was intravenously injected into rats at a dose equaled to 0.03 mg of Fe per 1 kg of an animal body weight. The elemental composition of liver tissue in rats subjected to IONPs action and controls were compared. Moreover, in order to determine the dynamics of nanoparticles (NPs) induced elemental changes, the tissues taken from animals 2 hours, 24 hours, and 7 days from IONPs injection were examined. The analysis of subtle elemental anomalies occurring as a result of IONPs action required application of highly sensitive analytical method. The total reflection X-ray fluorescence spectroscopy perfectly meets such requirements and therefore it was used in this study. The obtained results showed increasing trend of Fe level within liver occurring 2 hours from IONPs injection. One day after NPs administration, the liver Fe content presented the baseline level what suggests only the short-term accumulation of nanoparticles in the organ. The Ca, Cu, and Zn levels changed significantly as a result of NPs action. Moreover, the anomalies in their accumulation were still observed 7 days after IONPs injection. The level of Cu decreased while those of Ca and Zn increased in the liver of NPs-treated animals. The reduced liver Cu, followed by elevated serum level of this element, might be related in triggering the mechanisms responsible for Fe metabolism in the organism.

18 November 2020 in ACS Chemical Neuroscience
Verified
Journal Article
Open access
KPKarolina Planeta
Karolina Planeta
ZSZuzanna Setkowicz
Zuzanna Setkowicz
NJNatalia Janik-Olchawa
Natalia Janik-Olchawa
KMKatarzyna Matusiak
Katarzyna Matusiak
DRDamian Ryszawy
Damian Ryszawy
Joanna ChwiejJoanna Chwiej
Joanna Chwiej
Glioblastoma multiforme (GBM) is a primary brain tumor with a very high degree of malignancy and is classified by WHO as a glioma IV. At present, the treatment of patients suffering from GBM is based on surgical resection of the tumor with maximal protection of surrounding tissues followed by radio- and pharmacological therapy using temozolomide as the most frequently recommended drug. This strategy, however, does not guarantee success and has devastating consequences. Testing of new substances or therapies having potential in the treatment of GBM as well as detection of their side effects cannot be done on humans. Animal models of the disease are usually used for these purposes, and one possibility is the implantation of human tumor cells into rodent brains. Such a solution was used in the present study the purpose of which was comparison of elemental anomalies appearing in the brain as a result of implantation of different glioblastoma cell lines. These were two commercially available cell lines (U87MG and T98G), as well as tumor cells taken directly from a patient diagnosed with GBM. Using total reflection X-ray fluorescence we determined the contents of P, S, K, Ca, Fe, Cu, Zn, and Se in implanted-left and intact-right brain hemispheres. The number of elemental anomalies registered for both hemispheres was positively correlated with the invasiveness of GBM cells and was the highest for animals subjected to U87MG cell implantation, which presented significant decrease of P, K, and Cu levels and an increase of Se concentration within the left hemisphere. The abnormality common for all three groups of animals subjected to glioma cell implantation was increased Fe level in the brain, which may result from higher blood supply or the presence of hemorrhaging regions. In the case of the intact hemisphere, elevated Fe concentration may also indicate higher neuronal activity caused by taking over some functions of the left hemisphere impaired as a result of tumor growth.

12 March 2020 in Biological Trace Element Research
Verified
Journal Article
Open access
PDF file
MRMarzena Rugiel
Marzena Rugiel
ADAgnieszka Dróżdż
Agnieszka Dróżdż
KMKatarzyna Matusiak
Katarzyna Matusiak
ZSZuzanna Setkowicz
Zuzanna Setkowicz
KKKrzysztof Klodowski
Krzysztof Klodowski
Joanna ChwiejJoanna Chwiej
Joanna Chwiej
The systemic influence of iron oxide nanoparticles on the elemental homeostasis of key organs was examined in male rats. In tissues taken at different intervals from nanoparticles injection, the dynamics of elemental changes was analyzed. The organ metallome was studied using total reflection X-ray fluorescence. The obtained data were processed with advanced cluster and discriminant analyses—to classify the tissues according to their organs of origin and to distinguish accurately the nanoparticle-treated and normal rats. Additionally, in the case of liver and heart, it was possible to determine the elements of highest significance for different treatments, which may serve as markers of exposure to iron oxide nanoparticles.

23 October 2020 in Metallomics
Verified
Journal Article
Closed access
PDF file
KMKatarzyna Matusiak
Katarzyna Matusiak
ADAgnieszka Drozdz
Agnieszka Drozdz
ZSZuzanna Setkowicz
Zuzanna Setkowicz
AKAldona Kubala-Kukus
Aldona Kubala-Kukus
ISIlona Stabrawa
Ilona Stabrawa
JCJoanna Chwiej
Joanna Chwiej
In this study novel d-mannitol coated maghemite nanoparticles (MIONPs) are presented in terms of their influence on elemental homeostasis of living organisms and for this purpose highly sensitive total reflection X-ray fluorescence was used. Because of the biological indifference of d-mannitol and presumed lower toxicity of maghemite, compared to the most commonly used magnetite in nanomedicine, such nanoparticles seem to be promising candidates for biomedical applications. The examined dose of MIONPs was comparable with one of the lowest doses used in medical diagnostics. However, it should be emphasized that the amount of iron injected in this form is still significant compared to its total content in organs, especially in kidneys or the heart, and may easily disrupt their elemental homeostasis. The aim of the present study was to evaluate the elemental changes occurring in selected rat organs after injecting a low dose of MIONPs. The results were compared with those obtained for previously examined PEG-coated nanoparticles with magnetite cores. In the light of our findings the elemental changes observed after exposure to MIONPs were less extensive than those following PEG-coated magnetite nanoparticle administration.

10 September 2015 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
KMKatarzyna Matusiak
Katarzyna Matusiak
APAneta Patora
Aneta Patora
AJAleksandra Jung
Aleksandra Jung
The influence of pre- and post-irradiation annealing procedures on LiF:Mg,Cu,P (trade name MCP-N) thermoluminescent detector stability was investigated. The detectors were processed in four groups, undergoing complete or incomplete preparation cycles (containing pre- and/or post-irradiation annealing in various combinations). Each cycle was repeated 10 times. The decrease in the stability was observed in groups with pre-irradiation annealing procedure, and not observed in other groups that were found to be apparently stable. The influence of the thermal history on the properties of the detectors was also investigated by swapping the chosen groups of detectors with respect to the annealing cycles. Changes in the properties of the detectors were observed after next 10 cycles of measurements too. Exponential model was proposed to describe the trends observed at two parts of the experiment. Its application for the dose corrections related to the cycle number of the readout improves the accuracy of final dose determination.