High-performance MEMS gyroscope puts forward the higher request to the scale factor nonlinearity especially in variable-temperature environment. The scale factor nonlinearity over full temperature range rarely studies. In this paper, we focuses on the scale factor nonlinearity over full temperature range. The variations of the scale factor nonlinearity as the temperature were tested based on the MEMS butterfly gyroscope. The experimental results showed the U-shape curve of the output rate error so that the scale factor nonlinearity got large. The theoretical model of the scale factor was built and the phase error was found to be responsible for the U-shape error curve. Meanwhile, the phase error was identified to be variable over full temperature range experimentally, which meant it was critical to compensate the phase error in real time for improving the scale factor nonlinearity over full temperature range. A novel close-loop phase compensation system was designed by introducing a disturbance signal and experiments showed phase error was compensated in real time. After real-time phase compensation, the U-shape curve of the output rate error was eliminated and the scale factor nonlinearity decreased by about 10 times from 212.5 $ppm$ to 19.5 $ppm$ at the temperature ranged from $-$ 40 $^{\circ}C$ to 80 $^{\circ}C$ , which reached an excellent level for the rate MEMS gyroscopes.2023-0006
In this paper, a tuning fork gyroscope with a polygon-shaped vibration beam is proposed. The vibration structure of the gyroscope consists of a polygon-shaped vibration beam, two supporting beams, and four vibration masts. The spindle azimuth of the vibration beam is critical for performance improvement. As the spindle azimuth increases, the proposed vibration structure generates more driving amplitude and reduces the initial capacitance gap, so as to improve the signal-to-noise ratio (SNR) of the gyroscope. However, after taking the driving amplitude and the driving voltage into consideration comprehensively, the optimized spindle azimuth of the vibration beam is designed in an appropriate range. Then, both wet etching and dry etching processes are applied to its manufacture. After that, the fabricated gyroscope is packaged in a vacuum ceramic tube after bonding. Combining automatic gain control and weak capacitance detection technology, the closed-loop control circuit of the drive mode is implemented, and high precision output circuit is achieved for the gyroscope. Finally, the proposed Micro Electro Mechanical Systems (MEMS) gyroscope system demonstrates a bias instability of 0.589°/h, an angular random walk (ARW) of 0.038°/√h, and a bandwidth of greater than 100 Hz in a full scale range of ± 200°/s at room temperature.
11 May 2018 in Journal of Micromechanics and Microengineering
Through Glass Via (TGV) substrate plays an important role in wafer-level vacuum packaging of Micro-Electro-Mechanical System (MEMS) devices. For TGV fabrication, glass reflow is the critical step. In this paper, the theoretical formula was derived from the analogy between fluid equation and circuit equation which is able to describe the process of glass reflow. Parameters such as heating time, temperature, width of the gap and surface tension were considered in the theoretical model, which significantly influence the reflow speed. Simulations were also conducted and the results were compatible with the theoretical results. Moreover, both the theoretical formula and simulation results agree with the experimental results in the two types of fabricating process, including wet etching and deep reactive ion etching, showing the feasibility for providing parameters for glass reflow process in the different techniques.
MEMS butterfly gyroscope is one of the most potential high-precision x/y axis gyroscopes, whose vibration beam as the critical component has a large effect on its performance. This paper researched the influence of the spindle azimuth on the vibration beam by building a mathematical model, which found the larger and more robust spindle azimuth to process variation benefited the sensitivity and quadrature error. A novel butterfly gyroscope with a concave vibration beam was proposed. And the effect of its parameters on spindle azimuth was analyzed theoretically, which helped to propose a method for designing the most optimal concave vibration beam. In the presence of the same fabrication error, the robustness of the spindle azimuth to process variation was improved about double theoretically compared to the former vibration beam. The fabrication process and corresponding control system were designed and conducted. Experiments appeared that the butterfly gyroscope with a concave vibration beam was nearly half in the quadrature error ratio(avg 0.869) than the former(avg 1.669). More importantly, the distribution of the quadrature error in the novel butterfly gyroscopes was more concentrated. Their standard deviation was calculated as 0.292 which was nearly half of that of the oblique beam(0.579). It meant the concave beam appeared better robustness to process variation.
Thermal stress is one of the most important factors damaging the temperature-dependent performance of MEMS gyroscopes. To reduce thermal stress and improve their performance, this paper deduced the production and effects of thermal stress on a high-precision MEMS butterfly gyroscope theoretically, which provided a basis for optimization and experiments. A novel cantilever plate structure was designed based on the working modes of the MEMS butterfly gyroscope and optimized based on our simulation to achieve stress isolation. The simulation results showed that after integrating the cantilever plate structure, the stress acting on the MEMS butterfly gyroscope was reduced by 346 times, while the average capacitance gap error was also reduced by 36 times within the same variable temperature range. In addition, the cantilever plate structure was fabricated and integrated with the MEMS butterfly gyroscope. Experiments were also conducted to demonstrate the effect of reducing the thermal stress, and the results showed that the frequency variation was reduced by 28.6% and the bias stability increased by about 2 times over the full temperature range after integrating the cantilever plate structure into the gyroscope. This demonstrated that the cantilever plate structure can effectively reduce thermal stress and improve the performance of the MEMS butterfly gyroscope.