Zhanqiang Hou

Dr. Zhanqiang Hou


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
XZXin Zhou
Xin Zhou
DXDingbang Xiao
Dingbang Xiao
XWXuezhong Wu
Xuezhong Wu
YWYulie Wu
Yulie Wu
ZHZhanqiang Hou
Zhanqiang Hou
QLQingsong Li
Qingsong Li
We propose a stiffness-mass decoupling concept for designing large effective mass, low resonant frequency, small size, and high quality factor micro/nanomechanical resonators. This technique is realized by hanging lumped masses on the frame structure. An example of a stiffness-mass decoupled silicon disk resonator for gyroscopic application is demonstrated. It shows a decay time constant of 8.695 s, which is at least 5 times longer than that of the pure frame silicon disk resonator and is even comparable with that of the micromachined three-dimensional wine-glass resonators made from diamond or fused silica. The proposed design also shows a Brownian noise induced angle random walk of 0.0009°/√h, which is suitable for making an inertial grade MEMS gyroscope.

26 March 2015 in AIP Advances
Verified
Journal Article
Open access
PDF file
DXDingbang Xiao
Dingbang Xiao
SCShijie Cao
Shijie Cao
ZHZhanqiang Hou
Zhanqiang Hou
ZCZhihua Chen
Zhihua Chen
XWXinghua Wang
Xinghua Wang
XWXuezhong Wu
Xuezhong Wu
A new approach to improve the performance of a butterfly gyroscope is developed. The methodology provides a simple way to improve the gyroscope’s sensitivity and stability, by reducing the resonant frequency mismatch between the drive and sense modes. This method was verified by simulations and theoretical analysis. The size of the hexagonal section oblique beam is the major factor that influences the resonant frequency mismatch. A prototype, which has the appropriately sized oblique beam, was fabricated using precise, time-controlled multilayer pre-buried masks. The performance of this prototype was compared with a non-tuned gyroscope. The scale factor of the prototype reaches 30.13 mV/ ˚/s, which is 15 times larger than that obtained from the non-tuned gyroscope. The bias stability of the prototype is 0.8 ˚/h, which is better than the 5.2 ˚/h of the non-tuned devices.

25 November 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
XQXu Qiang
Xu Qiang
ZHZhanqiang Hou
Zhanqiang Hou
YKYunbin Kuang
Yunbin Kuang
TMTongqiao Miao
Tongqiao Miao
FOFenlan Ou
Fenlan Ou
XWXuezhong Wu
Xuezhong Wu
In this paper, a tuning fork gyroscope with a polygon-shaped vibration beam is proposed. The vibration structure of the gyroscope consists of a polygon-shaped vibration beam, two supporting beams, and four vibration masts. The spindle azimuth of the vibration beam is critical for performance improvement. As the spindle azimuth increases, the proposed vibration structure generates more driving amplitude and reduces the initial capacitance gap, so as to improve the signal-to-noise ratio (SNR) of the gyroscope. However, after taking the driving amplitude and the driving voltage into consideration comprehensively, the optimized spindle azimuth of the vibration beam is designed in an appropriate range. Then, both wet etching and dry etching processes are applied to its manufacture. After that, the fabricated gyroscope is packaged in a vacuum ceramic tube after bonding. Combining automatic gain control and weak capacitance detection technology, the closed-loop control circuit of the drive mode is implemented, and high precision output circuit is achieved for the gyroscope. Finally, the proposed Micro Electro Mechanical Systems (MEMS) gyroscope system demonstrates a bias instability of 0.589°/h, an angular random walk (ARW) of 0.038°/√h, and a bandwidth of greater than 100 Hz in a full scale range of ± 200°/s at room temperature.

10 March 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
QLQingsong Li
Qingsong Li
DXDingbang Xiao
Dingbang Xiao
XZXin Zhou
Xin Zhou
ZHZhanqiang Hou
Zhanqiang Hou
MZMing Zhuo
Ming Zhuo
XWXuezhong Wu
Xuezhong Wu
The multiring disk resonator gyroscope (DRG) has been a candidate for high performance gyroscopes, however nowadays the finite element method (FEM) is the main method for its analysis due to its complex structure. In this paper we propose a new method to mathematically model the DRG for its vibrating modes and lumped parameters based on the component mode synthesis (CMS) method. Firstly, the natural frequencies and the associated mode shapes of the DRG are mathematically modeled and a comparison with the FEM results is conducted. It shows that the mode shapes of DRG obtained by FEM and mathematical modeling are identical and in the full ranges of geometrical parameters, natural frequency error of the simulation, and calculation results are limited in ±15%. It demonstrates the effectivity and feasibility of the mathematical modeling method. Then, based on the calculated natural frequencies and mode shapes, the lumped mass-spring model of the DRG and effects of geometry parameters on the lumped mass-spring parameters are investigated, which can be used on the design of the DRG. This mathematical modeling method can effectively improve the analyzing efficiency of the DRG and the method can also be used on the analysis of other complex multiring-type resonators.

22 January 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
XZXin Zhou
Xin Zhou
DXDingbang Xiao
Dingbang Xiao
QLQingsong Li
Qingsong Li
QHQian Hu
Qian Hu
ZHZhanqiang Hou
Zhanqiang Hou
ASASHWIN A. SESHIA
ASHWIN A. SESHIA
Quality factor is one of the most important parameters for a MEMS resonator. Most MEMS resonators are dominated by thermoelastic dissipation (TED). This paper demonstrates that the TED in a disk resonator that is made of (111) single-crystal silicon is surpassed by clamping loss. The stiffness-mass decoupling design method, combined with reducing the beam width, was used to engineer high QTED. Experiments show that Q of the (111) disk resonator have an upper boundary that is determined by the clamping loss caused by the unbalanced out-of-plane displacement. The origin of the out-of-plane displacement is explained by theory and simulation.

24 January 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
FOFenlan Ou
Fenlan Ou
ZHZhanqiang Hou
Zhanqiang Hou
TMTongqiao Miao
Tongqiao Miao
DXDingbang Xiao
Dingbang Xiao
XWXuezhong Wu
Xuezhong Wu
This paper is devoted to discussing the influence of thermal stress on the performance of the Butterfly Vibratory Gyroscope (BFVG). In many gyroscopes, due to the material properties and the fabrication processes, the deformation caused by residual stress or thermal mechanical stress is of great concern since it directly affects the performance. Here, a new stress-released structure was proposed to reduce the deformation to improve BFVG’s performance considering the symmetry of the electrode and the miniaturization of the structure. Its dimensional parameters relate to the effect of thermal stress release and the stiffness characteristics of the BFVG’s oblique beam. The single parameter analysis method was used to explore the influence of the parameters on the effect of thermal stress release to guide the optimal size of the final design. The effect of thermal stress release in the BFVG at the full range temperature was also tested after the fabrication. The results showed that the influence of thermal stress on the BFVG’s performance effectively reduced.