Hongbo Du

Hongbo Du

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Gang YaoGang Yao
Gang Yao
YCYuxiao Chen
Yuxiao Chen
Yang YangYang Yang
Yang Yang
YZYuanlin Zheng
Yuanlin Zheng
HDHongbo Du
Hongbo Du
LWLinjun Wu
Linjun Wu
The long-span double-deck truss girder bridge has become a recommend structural form because of its good performance on traffic capacity. However, the vortex-induced vibration (VIV) characteristics for double-deck truss girders are more complicated and there is a lack of related research. In this research, wind tunnel tests were utilized to investigate the VIV characteristics of a large-span double-deck truss girder bridge. Meanwhile, the VIV suppression effect of the aerodynamic mitigation measures was measured. Furthermore, the VIV suppression mechanism was studied from the perspective of vortex shedding characteristics. The results indicated that the double-deck truss girder had a significant VIV when the wind attack angles were +3° and +5°. The aerodynamic mitigation measures had an influence on the VIV response of the double-deck truss girder. The upper chord fairing and lower chord inverted L-shaped deflector plate played a crucial role in suppressing VIV. Numerical analysis indicated that vortex shedding above the upper deck or in the wake region may dominate vertical VIV, while vortex shedding in the wake region of the lower deck may dominate torsional VIV. The upper chord fairing and lower chord inverted L-shaped deflector plate disrupted the original vortex shedding pattern in both regions, thereby suppressing VIV. This research can provide a foundation for bridge design and vibration suppression measures for large-span double-deck truss girder bridges.

22 February 2023 in Fire
Verified
Journal Article
Open access
PDF file
Yang YangYang Yang
Yang Yang
HDHongbo Du
Hongbo Du
Gang YaoGang Yao
Gang Yao
Fire safety evacuation has been used in numerous different kinds of buildings. This research conducts a scientometric review of fire safety evacuation applications and advances in the buildings to clarify the research trends of fire evacuation in the future and provide guidance for relevant research. A total of 3312 journals and conference proceedings were analyzed through different dimensions. The result proves that evacuation environments concentrate mainly on residential building, commercial building, school, and railway station. The characteristics of the evacuee have been gradually refined in recent years, including children, the elderly, patients, and vulnerable groups. The main experimental approaches of fire safety evacuation are evacuation drills, site records, and VR/AR experiments. The crowd behavior models mainly consist of six types: a cellular automata model, a social force model, a lattice gas model, a game-theoretic model, an animal agent-based model, and a computer agent-based model. The analysis results in the theoretical method are becoming gradually closer to the behavioral characteristics and movement data of the crowd during the actual evacuation with improvements of practical considerations. The study of evacuation drills, disaster rescue, emergencies, and other external environmental factors will become the forefront of future research, and subway stations, airports, high-rise building, and other personnel places will be the focus of the study of crowd evacuation.

19 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Yang YangYang Yang
Yang Yang
HDHongbo Du
Hongbo Du
Gang YaoGang Yao
Gang Yao
XMXinlong Ma
Xinlong Ma
WMWulei Men
Wulei Men
As sustainable structures like steel structures become more widely used, so do their construction issues. Improper lifting measures of long-span spatial steel structures may delay the construction period and even cause safety accidents. These problems have hindered the realization of sustainable buildings. Few studies on long-span spatial steel structures considered time-varying mechanical characteristics during the construction process. During the construction process, it will be found that the installed structure does not meet the required accuracy, and the installed content needs to be removed and re-constructed. This will cause idle work and rework, which will result in a waste of resources and is not conducive to sustainable development. Therefore, it is necessary to study the lifting construction process of long-span spatial steel structures and form a refined construction method. Based on the lifting construction process of the maintenance hangar roof of Chengdu Tianfu International Airport, this study proposes a time-varying mechanical analysis method for synchronous and asynchronous integral lifting of long-span space steel structures basing the Building Information Model (BIM). The force on the lifting point is analyzed during the hoisting construction process when the single-point asynchronous integral lifting and the interlaced point asynchronous integral lifting are carried out. The adverse effect of the displacement difference between lifting points during asynchronous integral lifting is proved. It provides a reference for the safe construction of long-span spatial steel structure lifting and also helps to improve the sustainability of construction projects.

16 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Gang YaoGang Yao
Gang Yao
YCYuxiao Chen
Yuxiao Chen
Yang YangYang Yang
Yang Yang
YZYuanlin Zheng
Yuanlin Zheng
LWLinjun Wu
Linjun Wu
HDHongbo Du
Hongbo Du
Large-span suspension bridges are susceptible to wind loads. Therefore, a more precise analysis of their wind-induced vibration response is necessary to ensure the structure’s absolute safety. This investigation conducted wind tunnel tests for the construction and completion stages to reveal the vortex-induced vibration (VIV) phenomenon of a double-deck suspension bridge. The results showed that no VIV occurred during the construction stage. However, the inclusion of railings significantly deteriorated the aerodynamic performance of the suspension bridge, leading to significant VIV at +3° and +5° wind angles of attack. Additionally, reducing the railing ventilation rate can significantly suppress the VIV amplitude. A new analysis method based on computational fluid dynamics (CFD) simulation is proposed to investigate the VIV mechanism of the double-deck truss girder. Twenty-nine measurement points were used to explore the vortex that causes VIV. The numerical simulations found that the area above and aft of the upper deck dominated the vertical VIV, while the aft of the lower deck dominated the torsional VIV. Furthermore, the intensity of the vortex in these areas was significantly lower during the construction stage. Moreover, reducing the railing ventilation rate significantly suppresses the torsional VIV by reducing the intensity of the vortex in the region behind the lower deck.

29 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Gang YaoGang Yao
Gang Yao
LWLinjun Wu
Linjun Wu
Yang YangYang Yang
Yang Yang
MLMaoyi Liu
Maoyi Liu
YCYuxiao Chen
Yuxiao Chen
HDHongbo Du
Hongbo Du
This paper carried out wind tunnel tests and numerical analysis to study the effect of the spatial position of deflector plates on the vortex-induced vibration (VIV) of a double-deck truss girder. The wind tunnel tests found that setting the web deflector plate and the lower chord deflector plate significantly suppressed the VIV. In order to study the suppression mechanism of the deflector plate on VIV, numerical simulations were conducted using the computational fluid dynamics (CFD) method. We analyzed the suppression mechanism of the deflector plate on VIV by combining the vertical amplitude obtained by numerical simulation with the change in the vorticity magnitude and direction. The results showed that the flow velocity around the lower surface of the airflow was reduced, resulting in significantly lower vorticity at the exact position of the lower chord deflector plate and web deflector plate section compared to the original section. The web deflector plate and the lower chord deflector plate broke the vortex shedding mode in the wake flow region, and the vortex shedding frequency was far away from the self-oscillation frequency of the double-deck truss girder, thus suppressing the VIV.

26 May 2023 in Preprints.org
Verified
Preprint
Open access
YYYang Yang
Yang Yang
HDHongbo Du
Hongbo Du
GYGang Yao
Gang Yao
XMXinlong Ma
Xinlong Ma
WMWulei Men
Wulei Men
Improper lifting measures of long-span spatial steel structures during construction process may delay the construction period and even cause safety accidents. Few studies on long-span spatial steel structures considered time-varying mechanical characteristic during construction process. In order to achieve safe and efficient installation in a long-span spatial steel structure, this research presents a time-varying mechanical analysis of the synchronous and asynchronous integral lifting and a single and interlaced point’s asynchronous integral lifting analysis method of a long-span spatial steel structure. The results showed that in the case of asynchronous lifting of single point, the displacement influence on other members is related to the distance. The closer the distance from the lifting point, the greater the influence. In asynchronous integral lifting, the lifting point with large lifting force is first installed to the specified position, and the lifting point with small lifting force is installed to the specified position.