Soon-Yong Park

Prof. Soon-Yong Park

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2003 in Pattern Recognition Letters
Verified
Journal Article
Closed access
SPSoon-Yong Park
Soon-Yong Park
MSMurali Subbarao
Murali Subbarao

8 July 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JLJunesuk Lee
Junesuk Lee
SPSoon-Yong Park
Soon-Yong Park
This letter presents a real-time monocular visual-inertial simultaneous localization and mapping with point-line fusion and parallel-line fusion. The corner and line features provide plenty of information about object structures. In the 2D image plane, such corner and line features have a positional similarity. The corner feature represents an endpoint of an object's edge, and the line feature represents a straight edge. We propose two novel methods for fusing corner and line features to improve localization accuracy. The first method is for fusing corner and line features. Using the positional similarity of corner and line features, we search the relationship between two features by utilizing the proposed point-line coupled residual. The second method is for fusing parallel 3D lines. First, we search for line features clustered based on a vanishing point. Then, the outliers in the parallel 3D lines are removed using the proposed consistency check during the multi-view line clustering. Finally, the parallel 3D lines are used in the proposed parallel 3D line residual. Experimental results show that real-time localization accuracy is improved when two proposed residuals are integrated with the sliding-window optimization. The proposed PLF-VINS is compared with other state-of-the-art algorithms using the public EuRoC dataset.

20 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
EKEung-su Kim
Eung-su Kim
SPSoon-Yong Park
Soon-Yong Park
This paper proposes a simple extrinsic calibration method for a multi-sensor system which consists of six image cameras and a 16-channel 3D LiDAR sensor using a planar chessboard. The six cameras are mounted on a specially designed hexagonal plate to capture omnidirectional images and the LiDAR sensor is mounted on the top of the plates to capture 3D points in 360 degrees. Considering each camera–LiDAR combination as an independent multi-sensor unit, the rotation and translation between the two sensor coordinates are calibrated. The 2D chessboard corners in the camera image are reprojected into 3D space to fit to a 3D plane with respect to the camera coordinate system. The corresponding 3D point data that scan the chessboard are used to fit to another 3D plane with respect to the LiDAR coordinate system. The rotation matrix is calculated by aligning normal vectors of the corresponding planes. In addition, an arbitrary point on the 3D camera plane is projected to a 3D point on the LiDAR plane, and the distance between the two points are iteratively minimized to estimate the translation matrix. At least three or more planes are used to find accurate external parameters between the coordinate systems. Finally, the estimated transformation is refined using the distance between all chessboard 3D points and the LiDAR plane. In the experiments, quantitative error analysis is done using a simulation tool and real test sequences are also used for calibration consistency analysis.

1 May 2005 in Machine Vision and Applications
Verified
Journal Article
Closed access
PDF file
SPSoon-Yong Park
Soon-Yong Park
MSMurali Subbarao
Murali Subbarao

27 December 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KSKavitha Muthu Subash
Kavitha Muthu Subash
TKTakio Kurita
Takio Kurita
SPSoon-Yong Park
Soon-Yong Park
SCSung-Il Chien
Sung-Il Chien
JBJae-Sung Bae
Jae-Sung Bae
Byeong-Cheol AhnByeong-Cheol Ahn
Byeong-Cheol Ahn
Pluripotent stem cells can potentially be used in clinical applications as a model for studying disease progress. This tracking of disease-causing events in cells requires constant assessment of the quality of stem cells. Existing approaches are inadequate for robust and automated differentiation of stem cell colonies. In this study, we developed a new model of vector–based convolutional neural network (V-CNN) with respect to extracted features of the induced pluripotent stem cell (iPSC) colony for distinguishing colony characteristics. A transfer function from the feature vectors to the virtual image was generated at the front of the CNN in order for classification of feature vectors of healthy and unhealthy colonies. The robustness of the proposed V-CNN model in distinguishing colonies was compared with that of the competitive support vector machine (SVM) classifier based on morphological, textural, and combined features. Additionally, five-fold cross-validation was used to investigate the performance of the V-CNN model. The precision, recall, and F-measure values of the V-CNN model were comparatively higher than those of the SVM classifier, with a range of 87–93%, indicating fewer false positives and false negative rates. Furthermore, for determining the quality of colonies, the V-CNN model showed higher accuracy values based on morphological (95.5%), textural (91.0%), and combined (93.2%) features than those estimated with the SVM classifier (86.7, 83.3, and 83.4%, respectively). Similarly, the accuracy of the feature sets using five-fold cross-validation was above 90% for the V-CNN model, whereas that yielded by the SVM model was in the range of 75–77%. We thus concluded that the proposed V-CNN model outperforms the conventional SVM classifier, which strongly suggests that it as a reliable framework for robust colony classification of iPSCs. It can also serve as a cost-effective quality recognition tool during culture and other experimental procedures.

9 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Udaya WijenayakeUdaya Wijenayake
Udaya Wijenayake
SPSoon-Yong Park
Soon-Yong Park
Accurate tracking and modeling of internal and external respiratory motion in the thoracic and abdominal regions of a human body is a highly discussed topic in external beam radiotherapy treatment. Errors in target/normal tissue delineation and dose calculation and the increment of the healthy tissues being exposed to high radiation doses are some of the unsolicited problems caused due to inaccurate tracking of the respiratory motion. Many related works have been introduced for respiratory motion modeling, but a majority of them highly depend on radiography/fluoroscopy imaging, wearable markers or surgical node implanting techniques. We, in this article, propose a new respiratory motion tracking approach by exploiting the advantages of an RGB-D camera. First, we create a patient-specific respiratory motion model using principal component analysis (PCA) removing the spatial and temporal noise of the input depth data. Then, this model is utilized for real-time external respiratory motion measurement with high accuracy. Additionally, we introduce a marker-based depth frame registration technique to limit the measuring area into an anatomically consistent region that helps to handle the patient movements during the treatment. We achieved a 0.97 correlation comparing to a spirometer and 0.53 mm average error considering a laser line scanning result as the ground truth. As future work, we will use this accurate measurement of external respiratory motion to generate a correlated motion model that describes the movements of internal tumors.