Haitao Yu

Dr. Haitao Yu


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Talanta
Verified
Journal Article
Closed access
YBYuyang Bao
Yuyang Bao
PXPengcheng Xu
Pengcheng Xu
SCShengran Cai
Shengran Cai
HYHaitao Yu
Haitao Yu
Xinxin LiXinxin Li
Xinxin Li

13 October 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Pengcheng XuPengcheng Xu
Pengcheng Xu
XLXinxin Li
Xinxin Li
HYHaitao Yu
Haitao Yu
TXTiegang Xu
Tiegang Xu
Functionalized nanoporous materials have been developed recently as bio/chemical sensing materials. Due to the huge specific surface of the nano-materials for molecular adsorption, high hopes have been placed on gravimetric detection with micro/nano resonant cantilevers for ultra-sensitive sensing of low-concentration bio/chemical substances. In order to enhance selectivity of the gravimetric resonant sensors to the target molecules, it is crucial to modify specific groups onto the pore-surface of the nano-materials. By loading the nanoporous sensing material onto the desired region of the mass-type transducers like resonant cantilevers, the micro-gravimetric bio/chemical sensors can be formed. Recently, such micro-gravimetric bio/chemical sensors have been successfully applied for rapid or on-the-spot detection of various bio/chemical molecules at the trace-concentration level. The applicable nanoporous sensing materials include mesoporous silica, zeolite, nanoporous graphene oxide (GO) and so on. This review article focuses on the recent achievements in design, preparation, functionalization and characterization of advanced nanoporous sensing materials for micro-gravimetric bio/chemical sensing.

25 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
XZxiaoyang zhang
xiaoyang zhang
ZCZhi Cao
Zhi Cao
Shanlai WangShanlai Wang
Shanlai Wang
LYLei Yao
Lei Yao
HYHaitao Yu
Haitao Yu
The traditional thermal gravimetric analyzer (TGA) has a noticeable thermal lag effect, which restricts the heating rate, while the micro-electro-mechanical system thermal gravimetric analyzer (MEMS TGA) utilizes a resonant cantilever beam structure with high mass sensitivity, on-chip heating, and a small heating area, resulting in no thermal lag effect and a fast heating rate. To achieve high-speed temperature control for MEMS TGA, this study proposes a dual fuzzy proportional-integral-derivative (PID) control method. The fuzzy control adjusts the PID parameters in real-time to minimize overshoot while effectively addressing system nonlinearities. Simulation and actual testing results indicate that this temperature control method has a faster response speed and less overshoot compared to traditional PID control, significantly improving the heating performance of MEMS TGA.

4 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XZxuelin zhang
xuelin zhang
YZYufan Zhou
Yufan Zhou
YCYing Chen
Ying Chen
MLMing Li
Ming Li
HYHaitao Yu
Haitao Yu
Xinxin LiXinxin Li
Xinxin Li
Transmission electron microscopy (TEM) is a highly effective method for scientific research, providing comprehensive analysis and characterization. However, traditional TEM is limited to observing static material structures at room temperature within a high-vacuum environment. To address this limitation, a microchip was developed for in situ TEM characterization, enabling the real-time study of material structure evolution and chemical process mechanisms. This microchip, based on microelectromechanical System (MEMS) technology, is capable of introducing multi-physics stimulation and can be used in conjunction with TEM to investigate the dynamic changes of matter in gas and high-temperature environments. The microchip design ensures a high-temperature uniformity in the sample observation area, and a system of tests was established to verify its performance. Results show that the temperature uniformity of 10 real-time observation windows with a total area of up to 1130 μm2 exceeded 95%, and the spatial resolution reached the lattice level, even in a flowing atmosphere of 1 bar.

7 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Shanlai WangShanlai Wang
Shanlai Wang
ZCZhi Cao
Zhi Cao
XZxiaoyang zhang
xiaoyang zhang
HYHaitao Yu
Haitao Yu
LYLei Yao
Lei Yao
Resonant microcantilevers have the advantages of ultra-high heating rates, analysis speed, ultra-low power consumption, temperature programming, and trace sample analysis when applied in TGA. However, the current single-channel testing system for resonant microcantilevers can only detect one sample at a time, and need two program heating tests to obtain the thermogravimetric curve of a sample. In many cases, it is desirable to obtain the thermogravimetric curve of a sample with a single-program heating test and to simultaneously detect multiple microcantilevers for testing multiple samples. To address this issue, this paper proposes a dual-channel testing method, where a microcantilever is used as a control group and another microcantilever is used as an experimental group, to obtain the thermal weight curve of the sample in a single program temperature ramp test. With the help of the LabVIEW’s convenient parallel running method, the functionality of simultaneously detecting two microcantilevers is achieved. Experimental validation showed that this dual-channel testing system can obtain the thermogravimetric curve of a sample with a single program heating test and detect two types of samples simultaneously.

13 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ZLZheng Lu
Zheng Lu
HJHao Jia
Hao Jia
DWDing Wang
Ding Wang
HYHaitao Yu
Haitao Yu
Micromechanical resonators have aroused growing interest as biological and chemical sensors, and microcantilever beams are the main research focus. Recently, a resonant microcantilever with an integrated heater has been applied in on-chip thermogravimetric analysis (TGA). However, there is a strong relationship between the mass sensitivity of a resonant microcantilever and the location of adsorbed masses. Different sampling positions will cause sensitivity differences, which will result in an inaccurate calculation of mass change. Herein, an integrated H-shaped resonant beam with uniform mass sensitivity and temperature distribution is proposed and developed to improve the accuracy of bio/chemical sensing and TGA applications. Experiments verified that the presented resonant beam possesses much better uniformity of sensitivity and temperature distribution compared with resonant microcantilevers. Gas-sensing and TGA experiments utilizing the integrated resonant beam were also carried out and exhibited good measurement accuracy.