Saulius Gudžius

Dr. Saulius Gudžius

Department of Electric Power Systems, Faculty of Electrical and Electronics Engineering, Kaunas University of Technology, Studentu str. 48, LT-51367 Kaunas, Lithuania

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SFSaad El Fallah
Saad El Fallah
JKJAOUAD KHARBACH
JAOUAD KHARBACH
JVJonas Vanagas
Jonas Vanagas
ZVZivile Vilkelyte
Zivile Vilkelyte
STSonata Tolvaišienė
Sonata Tolvaišienė
MJMohammed Ouazzani Jamil
Mohammed Ouazzani Jamil
Accurate estimation of the state of charge (SoC) of lithium-ion batteries is crucial for battery management systems, particularly in electric vehicle (EV) applications where real-time monitoring ensures safe and robust operation. This study introduces three advanced algorithms to estimate the SoC: deep neural network (DNN), gated recurrent unit (GRU), and long short-term memory (LSTM). The DNN, GRU, and LSTM models are trained and validated using laboratory data from a lithium-ion 18650 battery and simulation data from Matlab/Simulink for a LiCoO2 battery cell. These models are designed to account for varying temperatures during charge/discharge cycles and the effects of battery aging due to cycling. This paper is the first to estimate the SoC by a deep neural network using a variable current profile that provides the SoC curve during both the charge and discharge phases. The DNN model is implemented in Matlab/Simulink, featuring customizable activation functions, multiple hidden layers, and a variable number of neurons per layer, thus providing flexibility and robustness in the SoC estimation. This approach uniquely integrates temperature and aging effects into the input features, setting it apart from existing methodologies that typically focus only on voltage, current, and temperature. The performance of the DNN model is benchmarked against the GRU and LSTM models, demonstrating superior accuracy with a maximum error of less than 2.5%. This study highlights the effectiveness of the DNN algorithm in providing a reliable SoC estimation under diverse operating conditions, showcasing its potential for enhancing battery management in EV applications.

16 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
PKPaulius Kozlovas
Paulius Kozlovas
SGSaulius Gudžius
Saulius Gudžius
JCJokubas Ciurlionis
Jokubas Ciurlionis
AJAudrius Jonaitis
Audrius Jonaitis
IKInga Konstantinaviciute
Inga Konstantinaviciute
VBViktorija Bobinaite
Viktorija Bobinaite
This paper aimed at assessing the technical and economic potential of using rooftop solar photovoltaic (PV) systems in Lithuanian urban areas to support energy and climate policy formation and its implementation in the country. A bottom-up approach was applied. A number of apartment (AP), commercial (COM) and public (PUB) buildings, electric vehicle (EV) charging infrastructures and solar PV systems in the largest Lithuanian cities were analyzed, and the results were tailored to national-wide estimates. LiDAR and photogrammetry data of building topologies, geographical information systems (GIS), digital maps for rooftop measurements, factual solar photovoltaic (PV) performance modeling, average profiles of solar PV systems, statistical data of energy consumption in buildings, levelized cost of energy (LCOE) models and the literature review method were used. The results of the assessment of selected buildings and their categories reveal that the rooftop area per installed PV unit was 14.1–18.3 m2/kW in AP buildings, followed by 18.0–18.6 m2/kW in COM and 6.1–18.3 m2/kW in PUB buildings; the factor of rooftop suitability for solar PV system installation varied in ranges of 31.5–85.4%, 48.9–99.4% and 50.1–88.2%, respectively. Corrected by expert judgement, these estimates served as inputs for the assessment of technical and economic potentials. Furthermore, energy generated by solar PV could be consumed locally with little supplied to the distribution grid, resulting in no or a limited need for expensive investments in infrastructure. In addition, locating an EV charger on the premises of COM or PUB buildings could improve the localized consumption of solar energy. Thus, rooftop solar PV systems in urban Lithuanian areas are preferable. The results of the technical potential analysis show that, on the rooftops of AP buildings, 272 MW could be installed, followed by 78 MW on roofs of PUB and 67 MW on COM buildings. If technical potential is extracted, EUR 332.7 million can be invested. The cost of energy produced by solar PV systems was estimated at 2.34–5.25 EURct/kWh, which is significantly lower than the prices of market and retail electricity, standing at 23 EURct/kWh and 24 EURct/kWh (with support from the government) in 2022, respectively. The research’s limitations are defined by the fact that average values were applied to estimate the technical and economic potential of rooftop solar PV systems; a limited number of building categories were analyzed; the category of private houses, which is minor in cities, was missed, and rural areas with a great number of private houses were not covered by this study.

27 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
JVJonas Vaicys
Jonas Vaicys
PNPovilas Norkevicius
Povilas Norkevicius
ABArtūras Baronas
Artūras Baronas
SGSaulius Gudžius
Saulius Gudžius
AJAudrius Jonaitis
Audrius Jonaitis
DPDimosthenis Peftitsis
Dimosthenis Peftitsis
The implementation of a dual electric system that is capable of operating with either constant current and variable voltage, or constant voltage and variable current appliances, is one of the possible options to solve low-intensity stochastic energy utilization problems from renewable energy sources. This research paper analyzes the potential benefit of a novel three-phase dual system power inverter over the conventional inverter used in a solar power plant. The concept of such a power inverter is explained, and the digital twin model is created in a MATLAB Simulink environment. The efficiency characteristic of the simulated inverter is compared to the efficiency characteristic of a real conventional inverter. A standalone data logging system and an additional data acquisition system were used to collect and process data from the real inverter. Comparison of the digital twin inverter and the real conventional inverter shows the potential benefit of this novel inverter technology. It is shown that the novel inverter can operate in a wider range of DC input power. The potential economic benefit is also presented and discussed in the paper.

31 July 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
PKPaulius Kozlovas
Paulius Kozlovas
SGSaulius Gudžius
Saulius Gudžius
AJAudrius Jonaitis
Audrius Jonaitis
IKInga Konstantinaviciute
Inga Konstantinaviciute
VBViktorija Bobinaite
Viktorija Bobinaite
GGGustas Giedraitis
Gustas Giedraitis
This paper aims to evaluate price cannibalization effects in forecasts of long-term electricity prices and substantiate their relevance on the profitability of renewables in the Baltic States from 2024 to 2033. Statistical data analysis, literature review, scenario method, and PLEXOS modeling were applied. Five scenarios were analyzed for developing renewable energy sources (RES) and load in Lithuania. In contrast, scenarios for Estonia and Latvia were based on assumptions derived from the countries’ national RES strategies. The results showed that the increase in RES capacities will halve electricity market prices from around 130 EUR/MWh in 2024 to 58 EUR/MWh in Latvia, 60 EUR/MWh in Estonia, and 60–77 EUR/MWh in Lithuania in 2033. In time-waving, the absolute and relative price cannibalization effects of renewables were found. In 2033, the loss of revenue from solar photovoltaic (PV) generators was estimated to be 5.5–17.0 EUR/MWh in Lithuania, 7.1 EUR/MWh in Latvia, and 5.6 EUR in Estonia. The case of onshore wind demonstrated revenue losses of 10.5–22.0 EUR/MWh in Lithuania, 12.0 EUR/MWh in Latvia, and 10.0 EUR/MWh in Estonia. After 2029, revenues received by RES electricity generators could not guarantee project profitability; therefore, market flexibility options will be required. The key innovative strategy to mitigate the price cannibalization effect is the demand-side response when leveraging demand flexibility. Typically, this is achieved by sending price signals to the consumers who, if they have any, shift their demand to lower price periods. This is easily applied within HVAC systems, smart electric vehicle charging, and smart home appliance usage. Such behavior would allow the price cannibalization effect to be decreased.

13 October 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MZMantas Zelba
Mantas Zelba
TDTomas Deveikis
Tomas Deveikis
JBJustinas Barakauskas
Justinas Barakauskas
ABArtūras Baronas
Artūras Baronas
SGSaulius Gudžius
Saulius Gudžius
AGAndreas Giannakis
Andreas Giannakis
Renewable energy implementation in residential-scale grid-connected systems is already popular, and the growth of such systems is increasing every year. Grid-connected solar systems are relatively simple to install and operate; in addition, such power plants are relatively inexpensive compared to other renewable sources and grid-connection options. However, most residential grid-connected system owners believe that they will become independent from a distribution system operator (DSO) once a renewable energy source (RES) becomes available. As a rule, after installation, without DSOs, grid-connected systems are typically shut down due to a faulty grid, despite RES availability; therefore, such RES grid-connected system owners at later phases aim to become at least partially independent of DSOs. After such a change, the importance of developing a grid-tied inverter connection to an off-grid system will increase. While developing such a system connection the main issue analyzed in this paper is to control the excess power without affecting the accumulated energy levels in a system. As a result, a solution for such a system structure is presented with its main advantage to control excess power without affecting the accumulated energy level.

29 November 2023 in Energies
Verified
Journal Article
Open access
PDF file
MPMantas Plienis
Mantas Plienis
TDTomas Deveikis
Tomas Deveikis
AJAudrius Jonaitis
Audrius Jonaitis
SGSaulius Gudžius
Saulius Gudžius
IKInga Konstantinavičiūtė
Inga Konstantinavičiūtė
DPDonata Putnaitė
Donata Putnaitė
The decline in power quality within electrical networks is adversely impacting the energy efficiency and safety of transmission elements. The growing prevalence of power electronics has elevated harmonic levels in the grid to an extent where their significance cannot be overlooked. Additionally, the increasing integration of renewable energy sources introduces heightened fluctuations, rendering the prediction and simulation of working modes more challenging. This paper presents an improved algorithm for calculating power transformer losses attributed to harmonics, with a comprehensive validation against simulation results obtained from the Power Factory application and real-world measurements. The advantages of the algorithm are that all evaluations are performed in real-time based on single-point measurements, and the algorithm was easy to implement in a Programmable Logic Controller (PLC). This allows us to receive the exchange of information to energy monitoring systems (EMSs) or with Power factor Correction Units (PFCUs) and control it. To facilitate a more intuitive understanding and visualization of potential hazardous scenarios related to resonance, an extra Dijkstra algorithm was implemented. This augmentation enables the identification of conditions, wherein certain branches exhibit lower resistance than the grid connection point, indicating a heightened risk of resonance and the presence of highly distorted currents. Recognizing that monitoring alone does not inherently contribute to increased energy efficiency, the algorithm was further expanded to assess transformer losses across a spectrum of Power Factory Correction Units power levels. Additionally, a command from a PLC to a PFCU can now be initiated to change the capacitance level and near-resonance working mode. These advancements collectively contribute to a more robust and versatile methodology for evaluating power transformer losses, offering enhanced accuracy and the ability to visualize potentially critical resonance scenarios.