A high temperature real-time accurate monitoring system based on photoelectric oscillation had been proposed and demonstrated. We use the narrow bandwidth characteristics of phase-shifting fiber Bragg grating (PS-FBG) to generate stable photoelectric oscillation signals. After the PS-FBG is ceramic packaged to adapt to and apply to 500 °C high temperature, the wavelength shift caused by temperature change is precisely responded by narrow linewidth PS-FBG, so the change of photoelectric oscillation signal can be monitored in real time with high precision. The experimental results show that the sensitivity is -1.24 GHz/°C and the linearity is -0.99953. The system has a resolution of 0.0083 °C. The test system has excellent potential application value in precise control of high temperature environment such as metal smelting, crystal growth, chemistry and pharmaceutical engineering.
This paper presents a highly sensitive, temperature-insensitive optical carrier microwave interferometry (OCMI) system using a cascaded three fiber Bragg grating (FBG) structure to generate an enhanced Vernier effect for sensing applications. The enhanced Vernier effect is created by superimposing the interferograms of two separate interferometers formed by pairing the sensing FBG with each reference FBG. Experimental and theoretical results show that in strain sensing, the sensitivity based on enhanced Vernier effect is -4.642 MHz/µε, which is 66.3 and 61.4 times higher than that of strain sensor based on two single interferometers used to generate the enhanced Vernier effect in this system respectively. Compared with the strain sensor based on traditional Vernier effect, this sensor has higher sensitivity, and in addition the amplification factor for measuring sensitivity can be easily adjusted by changing the spatial distance between the three cascade FBGs. Moreover, the temperature sensitivity is decreased from -38.318 MHz/°C to -71.384 kHz/°C with temperature compensation. The sensor exhibits high resolution, high sensitivity, and low cross-sensitivity, making it great potential for measuring small physical changes in complex environments.
An Erbium-doped fiber source with a near-Gaussian-shaped spectrum consisting of only a single peak, based on the double-stage energy matching and LPFGs, is proposed and demonstrated. A double-stage Erbium-doped fiber source system is built. The first-stage structure adopts the single-pass forward pumping method with a 15 m Erbium-doped fiber, while the second-stage structure adopts the backward-pumping method with a 26.5 m Erbium-doped fiber. The energy of the output spectrum is concentrated near the long wavelength (1560 nm) through the double-pump energy matching of the two stages. Long period fiber gratings (LPFGs) are used to filter the excess light near the short wavelength (1530 nm) in order to obtain a near-Gaussian-shaped spectrum consisting of only a single peak. The output power, pump conversion efficiency, line width, 3 dB bandwidth and mean wavelength of this near-Gaussian-shaped spectrum are tested and analyzed. When the pump powers of the first and second stages are 50 mW and 360 mW, respectively, the results show that a near-Gaussian-shaped spectrum with a power of 10.17 mW, spectral line width of 19.767 nm, and mean wavelength stability of −0.978 ppm/mW can be obtained. This research provides a method for the generation of a near-Gaussian-shaped spectrum with high output power and excellent mean wavelength stability, and it can produce multiple forms and energies of near-Gaussian-shaped spectra via this Erbium-doped fiber source.
A cantilever deflection fiber-optic sensor based on chirped fiber grating (CFG) Fabry–Perot (FP) cavity had been proposed and experimental demonstrated. Two CFBGs with the same chirped coefficient direction and grating parameters are written in one single-mode fiber by UV mask exposure to form the CFG-FP cavity. The central wavelength of two CFGs is 1549.6072 nm, the 3 dB bandwidth is 2.9897 nm, and the physical cavity length of two CFGs is 1 cm. The grating region of two CFGs are straightness fixed on a cantilever beam, forming a sensor. Then the optical properties of this sensor are tested with different stresses at different positions of the cantilever beam. The experimental results show that this sensor can obtain linear displacement of a cantilever beam, overcoming the abilities of the FBG sensor, which only performed point measurement defect. The wavelength drift sensitivity of the sensor is 2.31 pm/g, and linearity is 0.99916. This sensor has great application value in the precise measurement of cantilever beam type and two-dimensional scale strain.