The known amplitude-sensitive eddy-current method for measuring the thickness of non-conductive coatings on conductive non-magnetic base metals does not satisfy the accuracy requirements. A primary consideration is the significant influence of a change in the specific electrical conductivity of the base metals on results of measurements. In this study, we developed a technique for measuring the thickness of non-conductive coatings on non-magnetic conductive base metals by using the eddy-current amplitude-phase method and implemented algorithms to process obtained information. Our method considered the influence of the specific electrical conductivity of the base metals by forming a two-dimensional graduation characteristic of the thickness gauge by using several base metals with different specific electrical conductivity. The algorithm for point-in-polygon determination was applied, which allowed us to measure the thickness of the coatings and the specific electrical conductivity of the base metals as independent values. The equipment necessary to construct the two-dimensional graduation characteristic and the algorithm for calculation of the thickness are described in detail.
1 August 2024 in Russian Journal of Nondestructive Testing
The paper is devoted to the development of a finite element model of an eddy current probe designed to test the degree of soldering in lap-joint soldered connections of conductive busbars. A methodology for developing a finite element model has been devised that includes a geometric parameter that, when altered, leads to the remeshing of the finite element grid without affecting the test parameters of nondestructive testing. This allows for a series of signal measurements of the finite element model of the eddy current probe, followed by averaging, thereby ensuring acceptable accuracy. The test results confirm the functionality of the eddy current probe, with a defect size measurement range in the soldered joint from 0 to 100% and a guaranteed main absolute error in measuring the degree of soldering of 5%.
The article considers nondestructive testing of soldered lap joints of electric machines by means of a two-element eddy current tangential probe, excitation and measuring windings of which are placed on both sides of the test object. To ensure shielding from closely located current-conducting elements two active shielding windings are used. Using the tangential probe and reference blocks, replicating the shape and dimensions of the tested joint and imitating 0% and 100% soldering, allows measurement of soldering of busbar lap joints.
This article is devoted to the non-destructive testing of the soldering integrity of soldered lap joints of the current-carrying busbars in electrical machines’ stator windings. The design of a two-element eddy current probe with tangentially positioned coils and active shielding for measuring the soldering integrity of soldered lap joints is developed. This paper considers the method of suppressing the influence of stray parameters on the testing results and the method of correcting the measurements in the case of a deviation in the electrical conductivity of the conductive busbar material. The test results demonstrate the performance of the developed eddy current probe for determining the actual value of the soldering integrity of soldered lap joints in the range of 0–100% with a permissible relative error of no more than 5%.
The article describes the non-conductive coating thickness simulating system, designed for automatic graduation of the coating thickness gauge using a large number of graduation points. The accuracy of the non-conductive coating thickness simulating system has been evaluated. The procedure for graduation of the coating thickness gauge is described, taking into account the design features and ways to compensate for the main sources of errors of the non-conductive coating thickness simulating system.