VISAKH T

Mr. VISAKH T

Medical Imaging Technology, Manipal Academy of Higher Education, Manipal, India
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2024 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
LDLeena R David
Leena R David
WEWiam Elshami
Wiam Elshami
OLOlanrewaju Lawal
Olanrewaju Lawal
NPNitika Panakkal
Nitika Panakkal
VTVISAKH T
VISAKH T
MYMeliz Yuvalı
Meliz Yuvalı

30 December 2024 in Journal of Clinical Imaging Science
Verified
Journal Article
Open access
VTVISAKH T
VISAKH T
PSPriya Pattath Sankaran
Priya Pattath Sankaran
NPNITIKA C PANAKKAL
NITIKA C PANAKKAL
GBGunjan Banga
Gunjan Banga
PKPrakashini K
Prakashini K
Objectives: Cardiac computed tomography (CCT) plays a key role in diagnosing congenital heart disease (CHD), emphasizing the need for specialized protocols in newborns due to CHD’s complexity. The aim is to explore the relationship between peak enhancement time (PET) and various parameters during CHD assessment with CCT. Material and Methods: The study involved 38 CHD patients undergoing CCT, with observations made on their heart rate, respiratory rate, saturation, cardiac output, weight, height, and age. The PET for each case was determined, and Spearman’s rank correlation was employed to evaluate the association between these parameters and the PET. Results: The median PET was 20.63 s, with a mean aortic Hounsfield unit of 512.16 ± 160.56. A moderate negative correlation was found between PET and both heart rates (r = −0.42, P = 0.009) and respiratory rates (r = −0.41, P = 0.01), whereas a negligible positive correlation (r = 0.19, P = 0.25) was observed with SpO2. A moderate positive correlation was noted between PET and both weight (r = 0.44, P = 0.005) and height (r = 0.40, P = 0.01). In addition, there were significant differences in median PET across different age categories. Conclusion: The findings conclude that PET during CCT is significantly associated with heart rate and respiratory rate. An increase in these rates corresponds to a notable decrease in PET. Consequently, the study recommends minimizing scan delays in CCT for patients exhibiting higher heart rates.

5 August 2024 in Radiography
Verified
Journal Article
Open access
NVN.A. Varughese
N.A. Varughese
NPNITIKA C PANAKKAL
NITIKA C PANAKKAL
VTVISAKH T
VISAKH T
RKRajagopal Kadavigere
Rajagopal Kadavigere
VRVani Lakshmi R
Vani Lakshmi R
SSSuresh Sukumar
Suresh Sukumar
Contrast Enhanced Computed Tomography (CECT) abdomen and pelvis is a common imaging procedure. Hospitals typically follow fixed protocols of contrast volume administration for triple-phase CECT abdomen and pelvis scans and have found that patients are either underdosed or overdosed with respect to their body habitus. The aim of the study was to correlate different patient characteristics such as Total body weight (TBW), Lean Body Mass (LBM), Body Mass Index (BMI), Body Surface Area (BSA) and Blood Volume (BV) with aortic enhancement in the arterial and portal venous phases for CECT Abdomen and pelvis. A total of 106 patients who underwent triple-phase CECT abdomen & pelvis were retrospectively studied. A circular region-of-interest (ROI) of 100 mm2 was positioned on descending aorta for unenhanced, arterial, and portal venous phases to measure the aortic enhancement in Hounsfield's units. Measure of contrast attenuation (ΔH) was calculated from the difference of CT values on unenhanced images and contrast images. Correlation analysis was performed to evaluate the relation of patient body characteristics with aortic enhancement. Correlation analysis revealed that BMI exhibited the least correlation when compared to the other characteristics in both arterial (r = -0.3; p = 0.002) and portovenous phases (r = -0.35; p < 0.001) whereas TBW, LBW, BSA and BV reported moderate inverse correlations. BV was found to be the strongest of all characteristics under linear regression. The study supports the use of protocols that adjust contrast volume to either TBW, LBW, BSA, or BV for CT abdomen and pelvis scan. The right body parameter ensures optimal contrast enhancement, improving the visualization of anatomical structures and helps in adapting tailored contrast injection protocols.

SSSuresh Sukumar
Suresh Sukumar
SSShovan Saha
Shovan Saha
WDWinniecia Dkhar
Winniecia Dkhar
NPNITIKA C PANAKKAL
NITIKA C PANAKKAL
VTVISAKH T
VISAKH T
RKRajagopal Kadavigere
Rajagopal Kadavigere
Healthcare-associated infections (HCAIs) are a significant concern for both healthcare professionals and patients. With recent advances in imaging modalities, there is an increase in patients visiting the radiology department for diagnosis and therapeutic examination. The equipment used for the investigator is contaminated, which may result in HCAIs to the patients and healthcare professionals. Medical imaging professionals (MIPs) should have adequate knowledge to overcome the spread of infection in the radiology department. This systematic review aimed to examine the literature on the knowledge and precaution standard of MIPs on HCIAs. This study was performed with a relative keyword using PRISMA guidelines. The articles were retrieved from 2000 to 2022 using Scopus, PubMed, and ProQuest databases. The NICE public health guidance manual was used to assess the quality of the full-length article. The search yielded 262 articles, of which Scopus published 13 articles, PubMed published 179 articles, and ProQuest published 55 articles. In the present review, out of 262 articles, only 5 fulfilled the criteria that reported MIPs’ knowledge of Jordan, Egypt, Sri Lanka, France, and Malawi populations. The present review reported that MIPs have moderate knowledge and precautionary standards regarding HCIAs in the radiology department. However, due to the limited studies published in the literature, the current review limits the application of the outcome in the vast MIPs population. This review recommended further studies to be conducted among the MIPs worldwide to know the actual knowledge and precaution standards regarding HCIAs.

7 November 2018 in Asian Journal of Pharmaceutical and Clinical Research
Verified
Journal Article
Open access
PDF file
DSDolly Sharma
Dolly Sharma
VTVISAKH T
VISAKH T
Objective: The normal size of the abdominal aorta is expected to be <3 cm though the size changes with age as well as workload. There is a need to know the variation in size of the abdominal aorta to avoid the formation of aneurysm and further complications.Materials and Methods: This study was carried out at Kasturba Medical College after taking 130 patients considering the inclusion and exclusion criteria. 130 patients who all came for abdomen computed tomography (CT) were divided into 65 patients in each age group under 20–40 years and 40–80 years. The measurements of abdominal aorta were anteroposterior (AP) and right left (RL) measured at T12-L1 level on plain axial abdomen CT images on Extended Brilliance Workstation.Result: We observed that there was a statistical significant difference in the average AP diameter between the two age groups (p<0.001). Another finding was a statistical significant difference in the average RL diameter between the two age groups (p<0.001), and, hence the size of abdominal aorta varies with age.Conclusion: The proposed study concluded that there was variation in the size of abdominal aorta with age. These findings would be helpful in early detecting of aneurysm and in avoiding aortic dissection.

7 January 2019 in Asian Journal of Pharmaceutical and Clinical Research
Verified
Journal Article
Open access
PDF file
VTVISAKH T
VISAKH T
SSSuresh Sukumar
Suresh Sukumar
APAbhimanyu Pradhan
Abhimanyu Pradhan
Objective: The objective of this study was to estimate the entrance surface radiation dose to the thyroid region in a computed tomography (CT) brain scan. Methods: Unfors Multi-O-Meter equipment was used to measure the entrance surface at the thyroid region of adult patients ranging from 18 to 70 years of age. A total of 115 patients were included in the study based on convenience sampling. The Multi-O-Meter was kept at the thyroid region during the scan, and the values for entrance surface dose (ESD) were noted from its monitor after the scan was complete. Results: The obtained data were analyzed and violate normal distribution; therefore, the median and quartiles were computed. The overall median (Q1, Q2), ESD of the patients, was 1.335 (1.213, 1.529) mGy. The minimum and maximum dose values recorded were 1.015 mGy and 1.964 mGy, respectively. Conclusions: The result showed a significant amount of entrance surface radiation dose to the thyroid region while taking a brain scan. This data can be used for optimization of radiation protection while undergoing CT scans of brain to reduce exposure to thyroid region.