Objectives. This study aimed to develop a predictive model for work-related musculoskeletal disorders (WRMSDs) among radiographers. Methods. A survey was conducted in seven hospitals in two cities with radiographers using the ergonomic assessment for radiographers questionnaire. Logistic regression, confirmatory factor analysis and structural equation modelling (SEM) were utilized to establish statistical relationships between independent factors and musculoskeletal complaints. Results. Of 165 respondents, 75.2% reported musculoskeletal pain in the past 12 months, with lower back pain the most prevalent (58.8%). Adjusting for covariates, musculoskeletal pain significantly correlated with body mass index < 23 (odds ratio [OR] 0.06, 95% confidence interval [CI] [0.005, 0.914]), smoking status (OR 0.274, 95% CI [0.751, 6.195]), fixed work break schedule (OR 2.839, 95% CI [1.123, 7.176]), sustained posture (OR 4.854, 95% CI [1.203,19.594]) and prolonged standing or walking (OR 7.499, 95% CI [1.086, 51.753]). The fit measures indicate a moderately good fit of the proposed model to the observed data. However, latent variables did not exhibit significant associations with WRMSD in SEM. Conclusions. The model suggests that WRMSDs among radiographers moderately correlate with underweight, smoking status, fixed work breaks, sustained posture and extended periods of standing or walking. The absence of significant associations between latent variables and WRMSDs suggests the presence of unexplored factors influencing the outcome.Trial registration: Clinical Trials Registry India identifier: CTRI/2021/09/036992.
25 March 2020 in Biomedical and Pharmacology Journal
Contrast Enhanced Computed Tomography (CECT) abdomen and pelvis is a common imaging procedure. Hospitals typically follow fixed protocols of contrast volume administration for triple-phase CECT abdomen and pelvis scans and have found that patients are either underdosed or overdosed with respect to their body habitus. The aim of the study was to correlate different patient characteristics such as Total body weight (TBW), Lean Body Mass (LBM), Body Mass Index (BMI), Body Surface Area (BSA) and Blood Volume (BV) with aortic enhancement in the arterial and portal venous phases for CECT Abdomen and pelvis. A total of 106 patients who underwent triple-phase CECT abdomen & pelvis were retrospectively studied. A circular region-of-interest (ROI) of 100 mm2 was positioned on descending aorta for unenhanced, arterial, and portal venous phases to measure the aortic enhancement in Hounsfield's units. Measure of contrast attenuation (ΔH) was calculated from the difference of CT values on unenhanced images and contrast images. Correlation analysis was performed to evaluate the relation of patient body characteristics with aortic enhancement. Correlation analysis revealed that BMI exhibited the least correlation when compared to the other characteristics in both arterial (r = -0.3; p = 0.002) and portovenous phases (r = -0.35; p < 0.001) whereas TBW, LBW, BSA and BV reported moderate inverse correlations. BV was found to be the strongest of all characteristics under linear regression. The study supports the use of protocols that adjust contrast volume to either TBW, LBW, BSA, or BV for CT abdomen and pelvis scan. The right body parameter ensures optimal contrast enhancement, improving the visualization of anatomical structures and helps in adapting tailored contrast injection protocols.
Healthcare-associated infections (HCAIs) are a significant concern for both healthcare professionals and patients. With recent advances in imaging modalities, there is an increase in patients visiting the radiology department for diagnosis and therapeutic examination. The equipment used for the investigator is contaminated, which may result in HCAIs to the patients and healthcare professionals. Medical imaging professionals (MIPs) should have adequate knowledge to overcome the spread of infection in the radiology department. This systematic review aimed to examine the literature on the knowledge and precaution standard of MIPs on HCIAs. This study was performed with a relative keyword using PRISMA guidelines. The articles were retrieved from 2000 to 2022 using Scopus, PubMed, and ProQuest databases. The NICE public health guidance manual was used to assess the quality of the full-length article. The search yielded 262 articles, of which Scopus published 13 articles, PubMed published 179 articles, and ProQuest published 55 articles. In the present review, out of 262 articles, only 5 fulfilled the criteria that reported MIPs’ knowledge of Jordan, Egypt, Sri Lanka, France, and Malawi populations. The present review reported that MIPs have moderate knowledge and precautionary standards regarding HCIAs in the radiology department. However, due to the limited studies published in the literature, the current review limits the application of the outcome in the vast MIPs population. This review recommended further studies to be conducted among the MIPs worldwide to know the actual knowledge and precaution standards regarding HCIAs.
30 December 2024 in Journal of Clinical Imaging Science
Objectives: Cardiac computed tomography (CCT) plays a key role in diagnosing congenital heart disease (CHD), emphasizing the need for specialized protocols in newborns due to CHD’s complexity. The aim is to explore the relationship between peak enhancement time (PET) and various parameters during CHD assessment with CCT. Material and Methods: The study involved 38 CHD patients undergoing CCT, with observations made on their heart rate, respiratory rate, saturation, cardiac output, weight, height, and age. The PET for each case was determined, and Spearman’s rank correlation was employed to evaluate the association between these parameters and the PET. Results: The median PET was 20.63 s, with a mean aortic Hounsfield unit of 512.16 ± 160.56. A moderate negative correlation was found between PET and both heart rates (r = −0.42, P = 0.009) and respiratory rates (r = −0.41, P = 0.01), whereas a negligible positive correlation (r = 0.19, P = 0.25) was observed with SpO2. A moderate positive correlation was noted between PET and both weight (r = 0.44, P = 0.005) and height (r = 0.40, P = 0.01). In addition, there were significant differences in median PET across different age categories. Conclusion: The findings conclude that PET during CCT is significantly associated with heart rate and respiratory rate. An increase in these rates corresponds to a notable decrease in PET. Consequently, the study recommends minimizing scan delays in CCT for patients exhibiting higher heart rates.
Objectives: Radiation exposure has been a cause of concern in computed tomography imaging. Reducing radiation dose increases the image noise which can be compensated by using reconstruction techniques. Recently artificial intelligence-based reconstruction technique has been introduced. Therefore, the purpose of the study was to prospectively compare the image quality between Idose4 and Precise Image in normal BMI individuals. Methods: Sixty-six consecutive patients with a normal body habitus undergoing contrast-enhanced abdomen and pelvis scan were included in the study. All scans were performed using 100 kVp and tube current modulation. The acquired images were reconstructed to iDose4 and precise imaging. Quantitatively images were analyzed by placing regions of interest in different organs to estimate the image noise, signal-to-noise ratio, and contrast-to-noise ratio. Qualitative analysis was done by two radiologists on a five-point Likert scale. Results: Image noise was significantly reduced using Precise Image across the plain (9.11 ± 1.43 vs 8.18 ± 1.2), arterial (14.34 ± 2.1 vs 10.21 ± 1.5), and portovenous phase (14.78 ± 2.30 vs 11.97 ± 2.07) with maximum noise reduction in the arterial and portovenous phases. Signal-to-noise ratio and contrast-to-noise ratio was significantly improved in all the organs across the plain, arterial, and portovenous phases. Qualitative analysis showed no significant difference between Idose4 and Precise Image with regards to visualization of large vessels in the arterial and portovenous phases. However, precise image was graded better than Idose4 with respect to visualization/conspicuity, image noise, and artifacts. Conclusion: Precise Image can be useful in reducing the image noise and improving the signal-to-noise ratio and contrast-to-noise ratio in low-dose computed tomography protocol among normal BMI individuals.