Smoke plumes emitted from wildland-urban interface (WUI) wildfires contain toxic chemical substances that are harmful to human health, mainly due to the burning of synthetic components. Accurate measurement of these air toxics is necessary for understanding their impacts on human health. However, air pollution is typically measured using ground-based sensors, manned airplanes, or satellites, which all provide low-resolution data. Unmanned Aerial Vehicles (UAVs) have the potential to provide high-resolution spatial and temporal data due to their ability to hover in specific locations and maneuver with precise trajectories in 3-D space. This study investigates the use of an octocopter UAV, equipped with a customized air quality sensor package and a volatile organic compound (VOC) air sampler, for the purposes of collecting and analyzing air toxics data from wildfire plumes. The UAV prototype developed has been successfully tested during several prescribed fires conducted by the California Department of Forestry and Fire Protection (CAL FIRE). Data from these experiments were analyzed with emphasis on the relationship between the air toxics measured and the different types of vegetation/fuel burnt. BTEX compounds were found to be more abundant for hardwood burning compared to grassland burning, as expected.
10 November 2022 in Aerosol Science and Technology
Wet cooling towers are used in industrial processes, power plants, and heating, ventilation, and air conditioning systems. Their purpose is to reject waste heat from a system through evaporative cooling of process water. Due to their design, a small fraction of process water is emitted from the tower exit, termed “spray drift.” Dissolved solids contained within spray drift droplets are regulated as PM10 emissions by EPA AP-42. Here, we use a novel instrumentation package to measure particulate emissions from drift droplets at two cooling towers located at separate power plants. We find that drift droplet properties depend on the sampling position over the tower so multiple positions need to be sampled to accurately estimate emissions. We estimate 11 and 3.3 grams of PM10 are emitted from each tower per hour, with 78% and 87% of PM10 emissions also qualifying as PM2.5. AP-42 overestimates PM10 emissions by a factor of 2.4 for one tower and nearly 300 for the other. These results suggest that AP-42 may require revision to both accurately reflect lower PM10 emissions and account for unregulated PM2.5, which constitute the majority of emissions. GRAPHICAL ABSTRACT
27 April 2022 in Atmospheric Measurement Techniques
Measuring emissions from stacks is challenging due to accessibility and safety concerns and requires techniques to address a broad range of conditions and measurement challenges. One way to facilitate such measurements is to build an instrument package and then use a crane to hold the package over the emissions source. Here we describe such an instrument package that is used to characterize both wet droplet and dried aerosol emissions from cooling tower spray drift. In this application, the instrument package characterizes the velocity, size distribution, and concentration of the wet droplet emissions and the mass concentration and elemental composition of the dried PM2.5 and PM10 emissions. Subsequent papers will present and analyze the wet and dried emissions from individual towers.