Xiaojing Sun

Prof. Dr. Xiaojing Sun


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
TWTingting Wang
Tingting Wang
BJBolong Jiang
Bolong Jiang
XSXiaojing Sun
Xiaojing Sun
To predict and control the train-induced vibration in depot buildings, a case study of the depot of Tianjin Metro, Line 5, was conducted. The platform of the depot has been constructed and is in use, and the construction of over-track buildings has not been completed. Firstly, an in situ measurement was performed to obtain the train loads and validate the numerical model. Secondly, a finite element model of the track–soil–depot structure was established. The train was simplified as a series of two spring-mass models and the train load was simulated using the measured rail acceleration. The calculated results were validated by the measurement data. To predict the vibration responses of the over-track building to be built, a sub-system of the over-track building was added to the numerical model. Finally, the vibration control effect of vibration isolation bearings was discussed. The results indicate that vibrations exceeded guideline limits without mitigation measures in some rooms of the over-track building. The dominant frequency of the building floors is 31.5 Hz. Vibration isolation bearings effectively mitigated the vibrations, and the IL reached approximately 7–15 dB at about 31.5 Hz.

13 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
ZXZhuosheng Xu
Zhuosheng Xu
XSXiaojing Sun
Xiaojing Sun
CQChang Qiao
Chang Qiao
TWTingting Wang
Tingting Wang
MMMeng Ma
Meng Ma
Kelvin’s model is widely used to simulate the dynamic characteristic of a resilient mat under a slab track. To develop an effective calculation model for a resilient mat using a solid element, a three-parameter viscoelasticity model (3PVM) was employed. With the help of the user-defined material mechanical behavior, the proposed model was implemented in software ABAQUS. To validate the model, a laboratory test was performed on a slab track with a resilient mat. Then, a finite element model of the track-tunnel-soil system was built. The calculation results using the 3PVM was compared with those using Kelvin’s model and the test results. The results indicate that the 3PVM can better reflect the dynamic characteristics of resilient mat than Kelvin’s model, especially over 10 Hz. Compared with the test results, the 3PVM has an average error of 2.7 dB and a max error of 7.9 dB at 5 Hz.

3 December 2025 in Vibration
Verified
Journal Article
Open access
PDF file
Hu KaijianHu Kaijian
Hu Kaijian
XSXiaojing Sun
Xiaojing Sun
YRYang Ruoteng
Yang Ruoteng
RHRui Han
Rui Han
MMMeng Ma
Meng Ma
Elevated stations are essential auxiliary structures within the high-speed rail (HSR) network. The newly constructed integrated elevated station for bridge building possesses a distinctive construction and intricate force transmission pathways, complicating the assessment of the dynamic coupling of train vibrations. Consequently, it is essential to examine the dynamic reaction of trains at such stations. This study utilises numerical simulation and field measurement techniques to examine the dynamic features of the newly constructed integrated elevated station for bridge building. Initially, vibration tests were performed on existing integrated elevated stations for bridge construction to assess their dynamic properties. The collected data were utilised to validate the modelling approach and parameter selection for the numerical model of existing stations, yielding a numerical solution method appropriate for bridge-station integrated stations. Secondly, utilising this technology, a numerical model of the newly integrated elevated station for bridge construction was developed to examine its dynamic features. Moreover, the impact of spatial configuration, train velocity, and operational organisation on the dynamic characteristics was analysed in greater depth. The vibration response level in the waiting hall was assessed. Research results indicate that structural joints alter the transmission path of train vibration energy, thereby significantly affecting the vibration characteristics of the station. The vibration response under double-track operation is notably greater than that under single-track operation. When two trains pass simultaneously at a speed of 200 km/h or higher, or a single train passes at 350 km/h, the maximum Z-vibration level of the waiting hall floor exceeds 75 dB, which goes beyond the specification limit.

28 June 2017
Verified
Book Chapter
Closed access
PDF file
BLBin Li
Bin Li
XSXiaojing Sun
Xiaojing Sun
ZTZhongsheng Tan
Zhongsheng Tan
CYChang Yu
Chang Yu

8 April 2020
Verified
Book Chapter
Closed access
PDF file
LXLihui Xu
Lihui Xu
XSXiaojing Sun
Xiaojing Sun
RCRongning Cao
Rongning Cao