Fangqing Zhang

Dr. Fangqing Zhang

School of Power and Mechanical Engineering, Wuhan University, Wuhan, Hubei, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2025 in Renewable Energy
Verified
Journal Article
Closed access
PWPei Wang
Pei Wang
JGJiang Guo
Jiang Guo
FCFangjuan Cheng
Fangjuan Cheng
YGYifeng Gu
Yifeng Gu
FYFang Yuan
Fang Yuan
Fangqing ZhangFangqing Zhang
Fangqing Zhang

15 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZBZeng Bing
Zeng Bing
JGJiang Guo
Jiang Guo
Fangqing ZhangFangqing Zhang
Fangqing Zhang
WZWenqiang Zhu
Wenqiang Zhu
ZXZhihuai Xiao
Zhihuai Xiao
PFPeng Fan
Peng Fan
Oil-immersed transformer is one of the most important components in the power system. The dissolved gas concentration prediction in oil is vital for early incipient fault detection of transformer. In this paper, a model for predicting the dissolved gas concentration in power transformer based on the modified grey wolf optimizer and least squares support vector machine (MGWO-LSSVM) with grey relational analysis (GRA) and empirical mode decomposition (EMD) is proposed, in which the influence of transformer load, oil temperature and ambient temperature on gas concentration is taken into consideration. Firstly, GRA is used to analyze the correlation between dissolved gas concentration and transformer load, oil temperature and ambient temperature, and the optimal feature set affecting gas concentration is extracted and selected as the input of the prediction model. Then, EMD is used to decompose the non-stationary series data of dissolved gas concentration into stationary subsequences with different scales. Finally, the MGWO-LSSVM is used to predict each subsequence, and the prediction values of all subsequences are combined to get the final result. DGA samples from two transformers are used to verify the proposed method, which shows high prediction accuracy, stronger generalization ability and robustness by comparing with LSSVM, particle swarm optimization (PSO)-LSSVM, GWO-LSSVM, MGWO-LSSVM, EMD-PSO-LSSVM, EMD-GWO-LSSVM, EMD-MGWO-LSSVM, GRA-EMD-PSO-LSSVM and GRA-EMD-GWO-LSSVM.

13 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Fangqing ZhangFangqing Zhang
Fangqing Zhang
JGJiang Guo
Jiang Guo
YFYuan Fang
Yuan Fang
YSYongjie Shi
Yongjie Shi
ZLZhaoyang Li
Zhaoyang Li
Vibration monitoring and analysis play a crucial role in the fault diagnosis of hydroelectric units. However, accurate extraction and identification of fault features from vibration signals are challenging because of noise interference. To address this issue, this study proposes a novel denoising method for vibration signals based on improved complementary ensemble empirical mode decomposition with adaptive noise (ICEEMDAN), permutation entropy (PE), and singular value decomposition (SVD). The proposed method is applied for the analysis of hydroelectric unit sway monitoring. Firstly, the ICEEMDAN method is employed to process the signal and obtain several intrinsic mode functions (IMFs), and then the PE values of each IMF are calculated. Subsequently, based on a predefined threshold of PE, appropriate IMFs are selected for reconstruction, achieving the first denoising effect. Then, the SVD is applied to the signal after the first denoising effect, resulting in the SVD spectrum. Finally, according to the principle of the SVD spectrum and the variation in the singular value and its energy value, the signal is reconstructed by choosing the appropriate reconstruction order to achieve the secondary noise reduction effect. In the simulation and case analysis, the method is better than the commonly used wavelet threshold, SVD, CEEMDAN–PE, and ICEEMDAN–PE, with a signal-to-noise ratio (SNR) improvement of 6.9870 dB, 4.6789 dB, 8.9871 dB, and 4.3762 dB, respectively, and where the root-mean-square error (RMSE) is reduced by 0.1426, 0.0824, 0.2093 and 0.0756, respectively, meaning that our method has a better denoising effect and provides a new way for denoising the vibration signal of hydropower units.

9 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JGJiyuan Gao
Jiyuan Gao
JGJiang Guo
Jiang Guo
YFYuan Fang
Yuan Fang
TYTongqiang Yi
Tongqiang Yi
Fangqing ZhangFangqing Zhang
Fangqing Zhang
YMYang Meng
Yang Meng
With the continuous operation of analog circuits, the component degradation problem gradually comes to the forefront, which may lead to problems, such as circuit performance degradation, system stability reductions, and signal quality degradation, which could be particularly evident in increasingly complex electronic systems. At the same time, due to factors, such as continuous signal transformation, the fluctuation of component parameters, and the nonlinear characteristics of components, traditional fault localization methods are still facing significant challenges when dealing with large-scale complex circuit faults. Based on this, this paper proposes a fault-diagnosis method for analog circuits using the ECWGEO algorithm, an enhanced version of the GEO algorithm, to de-optimize the 1D-CNN with an attention mechanism to handle time–frequency fusion inputs. Firstly, a typical circuit-quad op-amp dual second-order filter circuit is selected to construct a fault-simulation model, and Monte Carlo analysis is used to obtain a large number of samples as the dataset of this study. Secondly, the 1D-CNN network structure is improved for the characteristics of the analog circuits themselves, and the time–frequency domain fusion input is implemented before inputting it into the network, while the attention mechanism is introduced into the network. Thirdly, instead of relying on traditional experience for network structure determination, this paper adopts a parameter-optimization algorithm for network structure optimization and improves the GEO algorithm according to the problem characteristics, which enhances the diversity of populations in the late stage of its search and accelerates the convergence speed. Finally, experiments are designed to compare the results in different dimensions, and the final proposed structure achieved a 98.93% classification accuracy, which is better than other methods.

25 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Fangqing ZhangFangqing Zhang
Fangqing Zhang
JGJiang Guo
Jiang Guo
YFYuan Fang
Yuan Fang
YQYuanfeng Qiu
Yuanfeng Qiu
PWPei Wang
Pei Wang
YGYifeng Gu
Yifeng Gu
In order to solve low-quality problems such as data anomalies and missing data in the condition monitoring data of hydropower units, this paper proposes a monitoring data quality enhancement method based on HDBSCAN-WSGAIN-GP, which improves the quality and usability of the condition monitoring data of hydropower units by combining the advantages of density clustering and a generative adversarial network. First, the monitoring data are grouped according to the density level by the HDBSCAN clustering method in combination with the working conditions, and the anomalies in this dataset are detected, recognized adaptively and cleaned. Further combining the superiority of the WSGAIN-GP model in data filling, the missing values in the cleaned data are automatically generated by the unsupervised learning of the features and the distribution of real monitoring data. The validation analysis is carried out by the online monitoring dataset of the actual operating units, and the comparison experiments show that the clustering contour coefficient (SCI) of the HDBSCAN-based anomaly detection model reaches 0.4935, which is higher than that of the other comparative models, indicating that the proposed model has superiority in distinguishing between the valid samples and anomalous samples. The probability density distribution of the data filling model based on WSGAIN-GP is similar to that of the measured data, and the KL dispersion, JS dispersion and Hellinger’s distance of the distribution between the filled data and the original data are close to 0. Compared with the filling methods such as SGAIN, GAIN, KNN, etc., the effect of data filling with different missing rates is verified, and the RMSE error of data filling with WSGAIN-GP is lower than that of other comparative models. The WSGAIN-GP method has the lowest RMSE error under different missing rates, which proves that the proposed filling model has good accuracy and generalization, and the research results in this paper provide a high-quality data basis for the subsequent trend prediction and state warning.

11 October 2023 in Electronics
Verified
Journal Article
Open access
PDF file
TXTunzhen Xie
Tunzhen Xie
XXXianglian Xu
Xianglian Xu
YFYuan Fang
Yuan Fang
YSYuanqing Song
Yuanqing Song
LWLei Wenyang
Lei Wenyang
Fangqing ZhangFangqing Zhang
Fangqing Zhang
In this paper, solving the problem of the noise covariance matrix parameters tuning of the extended Kalman filter (EKF) and unscented Kalman filter algorithms (UKF) is difficult. A speed estimation strategy for a permanent magnet synchronous motor (PMSM) based on particle swarm optimization (PSO) optimized Kalman filter (KF) series algorithms is proposed. By using MATLAB/Simulink, in this paper, 20 effective simulation experiments on the noise covariance matrix parameter optimization process are conducted to obtain the optimal covariance matrix parameters of the extended Kalman filter and unscented Kalman filter. Moreover, EKF, PSO-EKF, UKF, and PSO-UKF are also compared to verify the effectiveness of the particle swarm optimization algorithm in optimizing the systems using the extended Kalman filter and unscented Kalman filter. For the error of speed estimation, taking 4000 rpm as a reference, the system using PSO-EKF has improved by 2.125% compared to that using EKF, and the system applying PSO-UKF has improved by 0.55% compared to the system applying UKF. For the error of electrical angle estimation, taking the system errors of original algorithms as references, the system adopting PSO-EKF has decreased by 60% compared to that adopting EKF, and the system using PSO-UKF has decreased by 47% compared to the system using UKF.