Lily Bossin

Dr. Lily Bossin

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2022 in Nature Reviews Methods Primers
Verified
Journal Article
Closed access
PDF file
EYEduardo G. Yukihara
Eduardo G. Yukihara
SMStephen W. S. McKeever
Stephen W. S. McKeever
CAClaus E. Andersen
Claus E. Andersen
ABAdrie J. J. Bos
Adrie J. J. Bos
IBIan K. Bailiff
Ian K. Bailiff
JCJeppe Brage Christensen
Jeppe Brage Christensen

20 July 2016 in International Journal of Radiation Biology
Verified
Journal Article
Open access
EAElizabeth Ainsbury
Elizabeth Ainsbury
Christophe BadieChristophe Badie
Christophe Badie
SBStephen Barnard
Stephen Barnard
GMGrainne Manning
Grainne Manning
JMJayne Moquet
Jayne Moquet
CWClemens Woda
Clemens Woda
Purpose: RENEB, ‘Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,’ is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. Materials and methods: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. Results: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. Conclusions: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.

18 May 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JCJeppe Brage Christensen
Jeppe Brage Christensen
MTMichele Togno
Michele Togno
LBLily Bossin
Lily Bossin
OPOskari V Pakari
Oskari V Pakari
SSSairos Safai
Sairos Safai
EYEduardo Gardenali Yukihara
Eduardo Gardenali Yukihara
The objective of this study was to improve the precision of linear energy transfer (LET) measurements using $$\text {Al}_2\text {O}_3\text {:C}$$ Al 2 O 3 :C optically stimulated luminescence detectors (OSLDs) in proton beams, and, with that, improve OSL dosimetry by correcting the readout for the LET-dependent ionization quenching. The OSLDs were irradiated in spot-scanning proton beams at different doses for fluence-averaged LET values in the (0.4–6.5) $$\hbox {keV}\, \upmu \hbox {m}^{-1}$$ keV μ m - 1 range (in water). A commercial automated OSL reader with a built-in beta source was used for the readouts, which enabled a reference irradiation and readout of each OSLD to establish individual corrections. Pulsed OSL was used to separately measure the blue (F-center) and UV ( $$F^+$$ F + -center) emission bands of $$\text {Al}_2\text {O}_3\text {:C}$$ Al 2 O 3 :C and the ratio between them (UV/blue signal) was used for the LET measurements. The average deviation between the simulated and measured LET values along the central beam axis amounts to 5.5% if both the dose and LET are varied, but the average deviation is reduced to 3.5% if the OSLDs are irradiated with the same doses. With the measurement procedure and automated equipment used here, the variation in the signals used for LET estimates and quenching-corrections is reduced from 0.9 to 0.6%. The quenching-corrected OSLD doses are in agreement with ionization chamber measurements within the uncertainties. The automated OSLD corrections are demonstrated to improve the LET estimates and the ionization quenching-corrections in proton dosimetry for a clinically relevant energy range up to 230 MeV. It is also for the first time demonstrated how the LET can be estimated for different doses.

12 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
LBLily Bossin
Lily Bossin
IPIgor Plokhikh
Igor Plokhikh
JCJeppe Brage Christensen
Jeppe Brage Christensen
DGDariusz Jakub Gawryluk
Dariusz Jakub Gawryluk
YKYuuki Kitagawa
Yuuki Kitagawa
EYEduardo Gardenali Yukihara
Eduardo Gardenali Yukihara
The objective of this work is to review and assess the potential of MgB4O7:Ce,Li to fill in the gaps where the need for a new material for optically stimulated luminescence (OSL) dosimetry has been identified. We offer a critical assessment of the operational properties of MgB4O7:Ce,Li for OSL dosimetry, as reviewed in the literature and complemented by measurements of thermoluminescence spectroscopy, sensitivity, thermal stability, lifetime of the luminescence emission, dose response at high doses (>1000 Gy), fading and bleachability. Overall, compared with Al2O3:C, for example, MgB4O7:Ce,Li shows a comparable OSL signal intensity following exposure to ionizing radiation, a higher saturation limit (ca 7000 Gy) and a shorter luminescence lifetime (31.5 ns). MgB4O7:Ce,Li is, however, not yet an optimum material for OSL dosimetry, as it exhibits anomalous fading and shallow traps. Further optimization is therefore needed, and possible avenues of investigation encompass gaining a better understanding of the roles of the synthesis route and dopants and of the nature of defects.

1 December 2018 in Radiation Measurements
Verified
Journal Article
Open access
LBLily Bossin
Lily Bossin
IBIan K. Bailiff
Ian K. Bailiff
ITIan Terry
Ian Terry

1 June 2020 in Radiation Measurements
Verified
Journal Article
Closed access
LBLily Bossin
Lily Bossin
IBIan Bailiff
Ian Bailiff
ITIan Terry
Ian Terry