Jeppe Brage Christensen

Dr. Jeppe Brage Christensen

Paul Scherrer Institute, Villigen, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2022 in Nature Reviews Methods Primers
Verified
Journal Article
Closed access
PDF file
EYEduardo G. Yukihara
Eduardo G. Yukihara
SMStephen W. S. McKeever
Stephen W. S. McKeever
CAClaus E. Andersen
Claus E. Andersen
ABAdrie J. J. Bos
Adrie J. J. Bos
IBIan K. Bailiff
Ian K. Bailiff
JCJeppe Brage Christensen
Jeppe Brage Christensen

15 April 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JCJeppe Brage Christensen
Jeppe Brage Christensen
MTMichele Togno
Michele Togno
KNKonrad Pawel Nesteruk
Konrad Pawel Nesteruk
Serena PsoroulasSerena Psoroulas
Serena Psoroulas
DMDavid Meer
David Meer
SSSairos Safai
Sairos Safai
The response of Al 2 O 3 :C optically stimulated luminescence detectors (OSLDs) was investigated in a 250 MeV pencil proton beam. The OSLD response was mapped for a wide range of average dose rates up to 9000 Gy s −1 , corresponding to a ∼150 kGy s −1 instantaneous dose rate in each pulse. Two setups for ultra-high dose rate (FLASH) experiments are presented, which enable OSLDs or biological samples to be irradiated in either water-filled vials or cylinders. The OSLDs were found to be dose rate independent for all dose rates, with an average deviation <1% relative to the nominal dose for average dose rates of (1–1000) Gy s −1 when irradiated in the two setups. A third setup for irradiations in a 9000 Gy s −1 pencil beam is presented, where OSLDs are distributed in a 3 × 4 grid. Calculations of the signal averaging of the beam over the OSLDs were in agreement with the measured response at 9000 Gy s −1 . Furthermore, a new method was presented to extract the beam spot size of narrow pencil beams, which is in agreement within a standard deviation with results derived from radiochromic films. The Al 2 O 3 :C OSLDs were found applicable to support radiobiological experiments in proton beams at ultra-high dose rates.

18 May 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JCJeppe Brage Christensen
Jeppe Brage Christensen
MTMichele Togno
Michele Togno
LBLily Bossin
Lily Bossin
OPOskari V Pakari
Oskari V Pakari
SSSairos Safai
Sairos Safai
EYEduardo Gardenali Yukihara
Eduardo Gardenali Yukihara
The objective of this study was to improve the precision of linear energy transfer (LET) measurements using $$\text {Al}_2\text {O}_3\text {:C}$$ Al 2 O 3 :C optically stimulated luminescence detectors (OSLDs) in proton beams, and, with that, improve OSL dosimetry by correcting the readout for the LET-dependent ionization quenching. The OSLDs were irradiated in spot-scanning proton beams at different doses for fluence-averaged LET values in the (0.4–6.5) $$\hbox {keV}\, \upmu \hbox {m}^{-1}$$ keV μ m - 1 range (in water). A commercial automated OSL reader with a built-in beta source was used for the readouts, which enabled a reference irradiation and readout of each OSLD to establish individual corrections. Pulsed OSL was used to separately measure the blue (F-center) and UV ( $$F^+$$ F + -center) emission bands of $$\text {Al}_2\text {O}_3\text {:C}$$ Al 2 O 3 :C and the ratio between them (UV/blue signal) was used for the LET measurements. The average deviation between the simulated and measured LET values along the central beam axis amounts to 5.5% if both the dose and LET are varied, but the average deviation is reduced to 3.5% if the OSLDs are irradiated with the same doses. With the measurement procedure and automated equipment used here, the variation in the signals used for LET estimates and quenching-corrections is reduced from 0.9 to 0.6%. The quenching-corrected OSLD doses are in agreement with ionization chamber measurements within the uncertainties. The automated OSLD corrections are demonstrated to improve the LET estimates and the ionization quenching-corrections in proton dosimetry for a clinically relevant energy range up to 230 MeV. It is also for the first time demonstrated how the LET can be estimated for different doses.

12 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
LBLily Bossin
Lily Bossin
IPIgor Plokhikh
Igor Plokhikh
JCJeppe Brage Christensen
Jeppe Brage Christensen
DGDariusz Jakub Gawryluk
Dariusz Jakub Gawryluk
YKYuuki Kitagawa
Yuuki Kitagawa
EYEduardo Gardenali Yukihara
Eduardo Gardenali Yukihara
The objective of this work is to review and assess the potential of MgB4O7:Ce,Li to fill in the gaps where the need for a new material for optically stimulated luminescence (OSL) dosimetry has been identified. We offer a critical assessment of the operational properties of MgB4O7:Ce,Li for OSL dosimetry, as reviewed in the literature and complemented by measurements of thermoluminescence spectroscopy, sensitivity, thermal stability, lifetime of the luminescence emission, dose response at high doses (>1000 Gy), fading and bleachability. Overall, compared with Al2O3:C, for example, MgB4O7:Ce,Li shows a comparable OSL signal intensity following exposure to ionizing radiation, a higher saturation limit (ca 7000 Gy) and a shorter luminescence lifetime (31.5 ns). MgB4O7:Ce,Li is, however, not yet an optimum material for OSL dosimetry, as it exhibits anomalous fading and shallow traps. Further optimization is therefore needed, and possible avenues of investigation encompass gaining a better understanding of the roles of the synthesis route and dopants and of the nature of defects.

11 July 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
SMS Motta
S Motta
JCJeppe Brage Christensen
Jeppe Brage Christensen
FFF Frei
F Frei
PPP Peier
P Peier
EYE G Yukihara
E G Yukihara
Objective. This work aims at investigating the response of various thermally stimulated luminescence detectors (TLDs) and optically stimulated luminescence detectors (OSLDs) for dosimetry of ultra-high dose rate electron beams. The study was driven by the challenges of dosimetry at ultra-high dose rates and the importance of dosimetry for FLASH radiotherapy and radiobiology experiments. Approach. Three types of TLDs (LiF:Mg,Ti; LiF:Mg,Cu,P; CaF 2 :Tm) and one type of OSLD (Al 2 O 3 :C) were irradiated in a 15 MeV electron beam with instantaneous dose rates in the (1–324) kGy s −1 range. Reference dosimetry was carried out with an integrating current transformer, which was calibrated in absorbed dose to water against a reference ionization chamber. Additionally, dose rate independent BeO OSLDs were employed as a reference. Beam non-uniformity was addressed using a matrix of TLDs/OSLDs. Main results. The investigated TLDs were shown to be dose rate independent within the experimental uncertainties, which take into account the uncertainty of the dosimetry protocol and the irradiation uncertainty. The relative deviation between the TLDs and the reference dose was lower than 4 % for all dose rates. A decreasing response with the dose rate was observed for Al 2 O 3 :C OSLDs, but still within 10 % from the reference dose. Significance. The precision of the investigated luminescence detectors make them suitable for dosimetry of ultra-high dose rate electron beams. Specifically, the dose rate independence of the TLDs can support the investigation of the beam uniformity as a function of the dose rate, which is one of the challenges of the employed beam. Al 2 O 3 :C OSLDs provided high precision measurements, but the decreasing response with the dose rate needs to be confirmed by additional experiments.

28 September 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JCJeppe Brage Christensen
Jeppe Brage Christensen
CAClaus E. Andersen
Claus E. Andersen
Ionization quenching in organic scintillators is usually corrected with methods that require careful assessment of the response relative to that of an ionization chamber. Here, we present a framework to compute ionization quenching correction factors (QCFs) from first principles for organic plastic scintillators exposed to ions. The tool solves the kinetic Blanc equation, of which the Birks model is a simplified solution, based on amorphous track structures models. As a consequence, ionization quenching correction factors can be calculated relying only on standard, tabulated scintillator material properties such as the density, light yield, and decay time. The tool is validated against experimentally obtained QCFs for two different organic plastic scintillators irradiated with protons with linear energy transfers (LETs) between 5– . The QCFs computed from amorphous track structure models and the BC-400 scintillator properties deviate less than 3% from the Birks model for LETs below and less than 5% for higher LETs. The agreement between experiments and the software for the BCF-12 scintillator is within 2% for LETs below and within 10% for LETs above, comparable to the experimental uncertainties. The framework is compiled into the open source software available for download. enables computations of QCFs in organic plastic scintillators exposed to ions independently of experimentally based quenching parameters in contrast to the Birks model. can improve the accuracy of correction factors and understanding of ionization quenching in scintillator dosimetry.