Amy Lenz

Dr. Amy Lenz


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
Amy LenzAmy Lenz
Amy Lenz
MSMarisa A. Strobel
Marisa A. Strobel
AAAbigail M. Anderson
Abigail M. Anderson
AFAlissa V. Fial
Alissa V. Fial
BMBruce A. MacWilliams
Bruce A. MacWilliams
KKKaren Kruger
Karen Kruger

7 September 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
NKNicola Krähenbühl
Nicola Krähenbühl
Amy LenzAmy Lenz
Amy Lenz
RLRich J. Lisonbee
Rich J. Lisonbee
APAndrew C. Peterson
Andrew C. Peterson
PAPenny R. Atkins
Penny R. Atkins
ABAlexej Barg
Alexej Barg

1 April 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
YSYantarat Sripanich
Yantarat Sripanich
JSJesse Steadman
Jesse Steadman
NKNicola Krähenbühl
Nicola Krähenbühl
CRChamnanni Rungprai
Chamnanni Rungprai
CSCharles L. Saltzman
Charles L. Saltzman
ABAlexej Barg
Alexej Barg

19 February 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
Amy LenzAmy Lenz
Amy Lenz
JNJennifer A. Nichols
Jennifer A. Nichols
KRKoren E. Roach
Koren E. Roach
KFK. Bo Foreman
K. Bo Foreman
ABAlexej Barg
Alexej Barg
AAAndrew E. Anderson
Andrew E. Anderson
Background: Tibiotalar arthrodesis is a common treatment for end-stage tibiotalar osteoarthritis, and is associated with a long-term risk of concomitant subtalar osteoarthritis. It has been clinically hypothesized that subtalar osteoarthritis following tibiotalar arthrodesis is the product of compensatory subtalar joint hypermobility. However, in vivo measurements of subtalar joint motion following tibiotalar arthrodesis have not been quantified. Using dual-fluoroscopy motion capture, we tested the hypothesis that the subtalar joint of the limb with a tibiotalar arthrodesis would demonstrate differences in kinematics and increased range of motion compared with the subtalar joint of the contralateral, asymptomatic, untreated ankle. Methods: Ten asymptomatic patients who had undergone unilateral tibiotalar arthrodesis at a mean (and standard deviation) of 4.0 ± 1.8 years previously were evaluated during overground walking and a double heel-rise task. The evaluation involved markerless tracking with use of dual fluoroscopy integrated with 3-dimensional computed tomography, which allowed for dynamic measurements of subtalar and tibiotalar dorsiflexion-plantar flexion, inversion-eversion, and internal-external rotation. Range of motion, stance time, swing time, step length, and step width were also measured. Results: During the early stance phase of walking, the subtalar joint of the limb that had been treated with arthrodesis was plantar flexed (−4.7° ± 3.3°), whereas the subtalar joint of the untreated limb was dorsiflexed (4.6° ± 2.2°). Also, during the early stance phase of walking, eversion of the subtalar joint of the surgically treated limb (0.2° ± 2.3°) was less than that of the untreated limb (4.5° ± 3.2°). During double heel-rise, the treated limb exhibited increased peak subtalar plantar flexion (−7.1° ± 4.1°) compared with the untreated limb (0.2° ± 1.8°). Conclusions: A significant increase in subtalar joint plantar flexion was found to be a primary compensation during overground walking and a double heel-rise activity following tibiotalar arthrodesis. Clinical Relevance: Significant subtalar joint plantar flexion compensations appear to occur following tibiotalar arthrodesis. We found an increase in subtalar plantar flexion and considered the potential relationship of this finding with the increased rate of subtalar osteoarthritis that occurs following ankle arthrodesis.

31 October 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
APAndrew C. Peterson
Andrew C. Peterson
KKKaren M. Kruger
Karen M. Kruger
Amy LenzAmy Lenz
Amy Lenz
Accurate analysis of bone position and orientation in foot and ankle studies relies on anatomical coordinate systems (ACS). Reliable ACSs are necessary for many biomechanical and clinical studies, especially those including weightbearing computed tomography and biplane fluoroscopy. Existing ACS approaches suffer from limitations such as manual input, oversimplifications, or non-physiological methods. To address these shortcomings, we introduce the Automatic Anatomical Foot and Ankle Coordinate Toolbox (AAFACT), a MATLAB-based toolbox that automates the calculation of ACSs for the major fourteen foot and ankle bones. In this manuscript, we present the development and evaluation of AAFACT, aiming to provide a standardized coordinate system toolbox for foot and ankle studies. The AAFACT was evaluated using a dataset of fifty-six models from seven pathological groups: asymptomatic, osteoarthritis, pilon fracture, progressive collapsing foot deformity, clubfoot, Charcot Marie Tooth, and cavovarus. Three analyses were conducted to assess the reliability of AAFACT. Firstly, ACSs were compared between automatically and manually segmented bone models to assess consistency. Secondly, ACSs were compared between individual bones and group mean bones to assess within-population precision. Lastly, ACSs were compared between the overall mean bone and group mean bones to assess the overall accuracy of anatomical representation. Statistical analyses, including statistical shape modeling, were performed to evaluate the reliability, accuracy, and precision of AAFACT. The comparison between automatically and manually segmented bone models showed consistency between the calculated ACSs. Additionally, the comparison between individual bones and group mean bones, as well as the comparison between the overall mean bone and group mean bones, revealed accurate and precise ACSs calculations. The AAFACT offers a practical and reliable solution for foot and ankle studies in clinical and engineering settings. It accommodates various foot and ankle pathologies while accounting for bone morphology and orientation. The automated calculation of ACSs eliminates the limitations associated with manual input and non-physiological methods. The evaluation results demonstrate the robustness and consistency of AAFACT, making it a valuable tool for researchers and clinicians. The standardized coordinate system provided by AAFACT enhances comparability between studies and facilitates advancements in foot and ankle research.

30 June 2021 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
ABArne Burssens
Arne Burssens
NKNicola Krähenbühl
Nicola Krähenbühl
Amy LenzAmy Lenz
Amy Lenz
KHKalebb Howell
Kalebb Howell
CZChong Zhang
Chong Zhang
ABAlexej Barg
Alexej Barg