Yuqi Wei

Yuqi Wei


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Yuqi WeiYuqi Wei
Yuqi Wei
QLQuanming Luo
Quanming Luo
AMAlan Homer Mantooth
Alan Homer Mantooth
In this paper, based on the LLC resonant converter fundamental harmonic analysis (FHA) model, the modulation strategies for LLC resonant converter can be categorized into the following three groups: 1) input voltage fundamental harmonic modulation; 2) resonant tank elements modulation; and 3) secondary equivalent impedance modulation. Operational principles and control diagrams for different modulation strategies are given. Comprehensive comparisons between these modulation strategies in terms of topology complexity, control complexity, and voltage gain range are presented with respect to the same system specifications. The advantages and disadvantages for each modulation strategy are summarized to provide guidance for engineers when analyzing and designing an LLC resonant converter. The hybrid modulation strategies are categorized into different groups based on the specific applications. Brief introductions of these hybrid modulation strategies are presented. Future trends regarding the modulation strategies of LLC resonant converters are presented.

6 April 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZWZhiqing Wang
Zhiqing Wang
QLQuanming Luo
Quanming Luo
Yuqi WeiYuqi Wei
Yuqi Wei
DMDI MOU
DI MOU
XLXinlei Lu
Xinlei Lu
PSPengju Sun
Pengju Sun
In order to realize power flow control among photovoltaic (PV) panel port, battery port, and load port in the distributed photovoltaic power generation system, integrated three-port DC/DC converters (TPCs) are widely adopted. The objective of this paper is to provide a comprehensive, comparative, and insightful analysis and overview of these TPCs. Firstly, based on the power transmission and control requirements of the system, five topological structures of a three-port DC/DC conversion system (TPCS) composed of two or three two-port DC/DC converters are presented. And the five structures are comparatively analyzed. Secondly, based on these topological structures, and combing with the basic two-port DC/DC converters, three groups of typical TPCs with different galvanic isolation requirements are derived respectively by sharing switches, combining branches, etc. And comprehensive analysis, comparisons, and reviews of these TPCs with different structures of each isolation type are presented with tables and figures. Finally, the comparison results of the three isolation groups are summarized, which leads to a guidance for the selection of TPCs in different applications, and then some suggestions for the future research on TPCs are given.

9 July 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
Shuang ZhaoShuang Zhao
Shuang Zhao
XZXingchen Zhao
Xingchen Zhao
Yuqi WeiYuqi Wei
Yuqi Wei
YZYue Zhao
Yue Zhao
HMHomer Alan Mantooth
Homer Alan Mantooth
Driving solutions for power semiconductor devices are experiencing new challenges since the emerging wide bandgap power devices, such as silicon carbide (SiC), with superior performance become commercially available. Generally, high switching speed is desired due to the lower switching loss, yet high dv/dt and di/dt can result in elevated electromagnetic interference (EMI) emission, false-triggering, and other detrimental effects during switching transients. Active gate drivers (AGDs) have been proposed to balance the switching losses and the switching speed of each switching transient. The review of the in-existence AGD methodologies for SiC devices has not been reported yet. This review starts with the essence of the slew rate control and its significance. Then a comprehensive review categorizing the state-of-the-art AGD methodologies is presented. It is followed by a summary of the AGDs control and timing strategies. In this work, using AGD to reduce the EMI noise of a 10 kV SiC MOSFET system is reported. This work also highlights other capabilities of AGDs including reliability enhancement of power devices and rebalancing the mismatched electrical parameters of parallel- and series-connected devices. These application scenarios of AGDs are validated via simulation and experimental results.

7 August 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Yuqi WeiYuqi Wei
Yuqi Wei
QLQuanming Luo
Quanming Luo
ZWZhiqing Wang
Zhiqing Wang
HMHomer Alan Mantooth
Homer Alan Mantooth
LLC resonant converters have been widely used in many different industrial applications. Analysis and design methodologies have great effect on the converter performance. Accordingly, a complete step by step optimal design methodology based on time domain analysis has been proposed for LLC resonant converter in this paper. The proposed design methodology is implemented under the worst operation condition, and the following considerations are included to obtain the suitable design area: 1) operation mode; 2) voltage stress for resonant capacitor; 3) zero voltage switching (ZVS) operation for primary switches; 4) resonant tank root-mean-square (RMS) current. Then, by finding all possible design candidates and comparing among them based on the power loss model, the optimized design candidate can be found. Compared with the existing design methodologies, the proposed one has the advantages of high accuracy and small computation requirement, which makes it application in industry possible. Finally, a 192 W experimental prototype was built to validate the effectiveness of the proposed design methodology. In addition, a MATLAB graphical user interference (GUI) program was built based on the proposed design methodology to visualize and facilitate the design process for engineers.

20 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HMHaider Mhiesan
Haider Mhiesan
Yuqi WeiYuqi Wei
Yuqi Wei
Yam SiwakotiYam Siwakoti
Yam Siwakoti
HMH. Alan Mantooth
H. Alan Mantooth
The cascaded H-bridge (CHB) inverter is one of the most attractive multilevel topologies for renewable energy applications. Due to the fact that CHB inverters employ a large number of components, they suffer from a higher probability of fault, which reduces the system reliability. A fault-tolerant operation for a CHB inverter is described in this article. New features ensure reliable and robust operation of the converter in the event of a fault. The proposed strategy uses an additional cross-coupled CHB (X-CHB) unit in companion with the existing CHB units to support the output voltage and ensure continuity of operation in the event of an open/short-circuit fault. The operation of the proposed X-CHB inverter is described in detail. Simulation and experimental verification of the proposed concept are demonstrated using a seven-level CHB. Both simulation and experimental results confirm the fault-tolerant operation of the X-CHB for a battery energy storage system in case of switch faults.

14 June 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Yuqi WeiYuqi Wei
Yuqi Wei
QLQuanming Luo
Quanming Luo
XDXiong Du
Xiong Du
NANecmi ALTIN
Necmi ALTIN
ANAdel Nasiri
Adel Nasiri
JAJ. Marcos Alonso
J. Marcos Alonso
In this paper, a dual half-bridge LLC resonant converter with magnetic control is proposed for the battery charger application. The primary switches are shared by two LLC resonant networks, and their outputs are connected in series. One of the LLC resonant converter is designed to operate at the series resonant frequency, which is also the highest efficiency operating point, and the constant output voltage characteristic is achieved at this operating point. The second LLC resonant converter adopts magnetic control to regulate the total output current and voltage during both constant current (CC) charge mode and constant voltage (CV) charge mode. Meanwhile, the function decoupling idea is adopted to further improve the system efficiency. The significant amount of the power is handled by the LLC resonant converter operating at the series resonant frequency, while the second LLC resonant converter fulfills the responsibility to achieve closed-loop control. By carefully designing the resonant networks, the zero-voltage switching (ZVS) for primary switches and zero-current switching (ZCS) for secondary diodes can be achieved for whole operation range. A 320W experimental prototype is built to verify the theoretical analysis, and the maximum efficiency is measured about 95.5%.