Yashar Ali Behnam

Mr. Yashar Ali Behnam

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
TAThor E. Andreassen
Thor E. Andreassen
LHLandon D. Hamilton
Landon D. Hamilton
DHDonald Hume
Donald Hume
SHSean E. Higinbotham
Sean E. Higinbotham
Yashar Ali BehnamYashar Ali Behnam
Yashar Ali Behnam
KSKevin B. Shelburne
Kevin B. Shelburne
Computational modeling is of growing importance in orthopedics and biomechanics as a tool to understand differences in pathology and predict outcomes from surgical interventions. However, the computational models of the knee have historically relied on in vitro data to create and calibrate model material properties due to the unavailability of accurate in vivo data. This work demonstrates the design and use of a custom device to quantify anterior-posterior (AP) and internal-external (IE) in vivo knee laxity, with an accuracy similar to existing in vitro methods. The device uses high-speed stereo radiography (HSSR) tracking techniques to accurately measure the resulting displacements of the femur, tibia, and patella bones during knee laxity assessment at multiple loads and knee flexion angles. The accuracy of the knee laxity apparatus was determined by comparing laxity data from two cadaveric specimens between the knee laxity apparatus and an existing in vitro robotic knee joint simulator. The accuracy of the knee laxity apparatus was within 1 mm (0.04 in.) for AP and 2.5 deg for IE. Additionally, two living subjects completed knee laxity testing to confirm the laboratory use of the novel apparatus. This work demonstrates the ability to use custom devices in HSSR to collect accurate data, in vivo, for calibration of computational models.

16 November 2023 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
Yashar Ali BehnamYashar Ali Behnam
Yashar Ali Behnam
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
HWHayden Wilson
Hayden Wilson
Chadd ClaryChadd Clary
Chadd Clary
Contemporary total knee arthroplasty (TKA) have not fully restored natural P-F mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop and verify a novel experimental simulation and corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofit with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to verify kinematic and kinetic predictions against experimental measurements. Patella alta reduced P-F reaction forces in early and mid-flexion, corresponding with an increase in T-F forces that indicated an increase in extensor mechanism efficiency. Due to reduced wrapping of the extensor mechanism in deeper flexion for the alta condition, peak P-F forces in flexion increased from 101% to 135% of the applied quadriceps load for baja and alta conditions, respectively. Strong agreement was observed between the experiment and model predictions with root mean square errors (RMSE) for P-F kinematics ranging from 0.8° to 3.3° and 0.7 mm to 1.4 mm. RMSE for P-F forces ranged from 7.4 N to 53.6 N. This novel experimental simulation and verified model will be a useful tool for future development of TKA implants.

2 November 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Yashar Ali BehnamYashar Ali Behnam
Yashar Ali Behnam
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
RLRenate List
Renate List
Chadd ClaryChadd Clary
Chadd Clary
The mechanism and boundary conditions used to drive experimental joint simulators have historically adopted standardized profiles developed from healthy, non-total knee arthroplasty (TKA) patients. The purpose of this study was to use implant-specific in vivo knee kinematics to generate physiologically relevant boundary conditions used in the evaluation of cadaveric knees post-TKA. Implant-specific boundary conditions were generated by combining in vivo fluoroscopic kinematics, musculoskeletal modeling-generated quadriceps loading, and telemetric knee compressive loading during activities of daily living (ADL) to dynamically drive a servo-hydraulic knee joint simulator. Ten cadaveric knees were implanted with the same TKA components and mounted in the knee simulator to verify the resulting load profiles against reported fluoroscopic kinematics and loading captured by an ultra-congruent telemetric knee implant. The cadaveric simulations resulted in implant-specific boundary conditions, which accurately recreate the in vivo performance of the like-implanted knee, with Root Mean Square Error (RMSE) in femoral low point kinematics below 2.0 mm across multiple activities of daily living. This study demonstrates the viability of in vivo fluoroscopy as the source of relevant boundary conditions for a novel knee loading apparatus, enabling dynamic cadaveric knee loading that aligns with clinical observations to improve the preclinical development of TKA component design.