Ahilan Anantha Krishnan

Dr. Ahilan Anantha Krishnan

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
Yashar Ali BehnamYashar Ali Behnam
Yashar Ali Behnam
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
HWHayden Wilson
Hayden Wilson
Chadd ClaryChadd Clary
Chadd Clary
Contemporary total knee arthroplasty (TKA) have not fully restored natural P-F mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop and verify a novel experimental simulation and corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofit with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to verify kinematic and kinetic predictions against experimental measurements. Patella alta reduced P-F reaction forces in early and mid-flexion, corresponding with an increase in T-F forces that indicated an increase in extensor mechanism efficiency. Due to reduced wrapping of the extensor mechanism in deeper flexion for the alta condition, peak P-F forces in flexion increased from 101% to 135% of the applied quadriceps load for baja and alta conditions, respectively. Strong agreement was observed between the experiment and model predictions with root mean square errors (RMSE) for P-F kinematics ranging from 0.8° to 3.3° and 0.7 mm to 1.4 mm. RMSE for P-F forces ranged from 7.4 N to 53.6 N. This novel experimental simulation and verified model will be a useful tool for future development of TKA implants.

28 December 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
CMCasey A. Myers
Casey A. Myers
CFClare Fitzpatrick
Clare Fitzpatrick
Chadd ClaryChadd Clary
Chadd Clary
Subject-specific hip capsule models could offer insights into impingement and dislocation risk when coupled with computer-aided surgery, but model calibration is time-consuming using traditional techniques. This study developed a framework for instantaneously generating subject-specific finite element (FE) capsule representations from regression models trained with a probabilistic approach. A validated FE model of the implanted hip capsule was evaluated probabilistically to generate a training dataset relating capsule geometry and material properties to hip laxity. Multivariate regression models were trained using 90% of trials to predict capsule properties based on hip laxity and attachment site information. The regression models were validated using the remaining 10% of the training set by comparing differences in hip laxity between the original trials and the regression-derived capsules. Root mean square errors (RMSEs) in laxity predictions ranged from 1.8° to 2.3°, depending on the type of laxity used in the training set. The RMSE, when predicting the laxity measured from five cadaveric specimens with total hip arthroplasty, was 4.5°. Model generation time was reduced from days to milliseconds. The results demonstrated the potential of regression-based training to instantaneously generate subject-specific FE models and have implications for integrating subject-specific capsule models into surgical planning software.

2 November 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Yashar Ali BehnamYashar Ali Behnam
Yashar Ali Behnam
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
RLRenate List
Renate List
Chadd ClaryChadd Clary
Chadd Clary
The mechanism and boundary conditions used to drive experimental joint simulators have historically adopted standardized profiles developed from healthy, non-total knee arthroplasty (TKA) patients. The purpose of this study was to use implant-specific in vivo knee kinematics to generate physiologically relevant boundary conditions used in the evaluation of cadaveric knees post-TKA. Implant-specific boundary conditions were generated by combining in vivo fluoroscopic kinematics, musculoskeletal modeling-generated quadriceps loading, and telemetric knee compressive loading during activities of daily living (ADL) to dynamically drive a servo-hydraulic knee joint simulator. Ten cadaveric knees were implanted with the same TKA components and mounted in the knee simulator to verify the resulting load profiles against reported fluoroscopic kinematics and loading captured by an ultra-congruent telemetric knee implant. The cadaveric simulations resulted in implant-specific boundary conditions, which accurately recreate the in vivo performance of the like-implanted knee, with Root Mean Square Error (RMSE) in femoral low point kinematics below 2.0 mm across multiple activities of daily living. This study demonstrates the viability of in vivo fluoroscopy as the source of relevant boundary conditions for a novel knee loading apparatus, enabling dynamic cadaveric knee loading that aligns with clinical observations to improve the preclinical development of TKA component design.

14 September 2026 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
SRShreya Raghavan
Shreya Raghavan
MHMaria A. Holland
Maria A. Holland

20 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
PDPhil G. Dinning
Phil G. Dinning
MHMaria A. Holland
Maria A. Holland
Purpose: Colonic motility disorders, including diarrhea-predominant irritable bowel syndrome and slow-transit constipation, impose a major clinical burden. Although high-resolution colonic manometry reveals characteristic spatiotemporal motor patterns, such as high-amplitude propagating contractions and cyclic motor pattern in healthy individuals, these patterns are often altered or absent in disease. Understanding how these patterns arise from underlying pacemaker, neural, and mechanical mechanisms is essential for improving treatment strategies. Methods: We developed a biophysical whole-colon model that integrates an Interstitial Cells of Cajal–inspired oscillator network, enteric nervous system reflexes, a pressure-gated modulation element motivated by rectosigmoid brake behavior, and a nonlinear tube law describing colon wall mechanics. The model simulates spatiotemporal pressure patterns along the colon and allows systematic variation of physiological parameters associated with pacemaker activity, neural reflex control, and distal gating. Results: A small set of parameters reproduces three illustrative motility patterns corresponding to healthy motility, diarrhea-predominant irritable bowel syndrome, and slow-transit constipation. The simulated pressure maps recapitulate key features observed in high-resolution manometry, including propagation direction, regional patterning of contractions, and case-specific changes in amplitude and coordination. Sensitivity analysis suggests that proximal excitation strength and waveform morphology strongly influence global motility metrics. Conclusion: Our study presents a simple, biophysical framework for reproducing clinically observed colonic motor patterns and exploring their disruption in disease. More broadly, the model may help interpret clinical manometry in mechanistic terms and support hypothesis-driven in silico studies of colonic motility disorders.

16 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
SRShreya Raghavan
Shreya Raghavan
MHMaria Holland
Maria Holland
Gastrointestinal (GI) symptoms are a prominent feature of Gulf War Illness (GWI). Animal models attribute them to pyridostigmine bromide (PB) exposure, which induces smooth muscle hypertrophy, neuroinflammation, and motility impairment. However, animal studies only provide static snapshots of disease progression and can only partially resolve how inflammatory, neuronal, and biomechanical processes interact dynamically over time. To address this gap, we developed a computational model that couples cytokine kinetics, macrophage activation, and an excitatory-inhibitory neuronal imbalance to predict smooth muscle hypertrophy and colonic motility changes in GWI. The model was calibrated using data from mice exposed to PB under acute (7-day exposure and measurement) and chronic (7-day exposure and 30-day measurement) conditions, reproducing measured cytokine IL-6 elevations, macrophage accumulation, circular muscle thickening, and shifts in excitatory and inhibitory gene expression. Simulations captured reduced excitatory stress, and sustained loss of inhibitory relaxation, consistent with organ-bath recordings. Sensitivity analyses identified macrophage persistence as a dominant regulator of chronic inhibitory dysfunction, whereas excitatory pathways exhibited relative robustness and recovery. Thus, our model provides a systems-level view of how acute PB-induced inflammation evolves into chronic dysmotility and establishes a first step towards a virtual platform for testing hypotheses and interventions translatable to neuroimmune GI disorders.