Eric Hedge

Mr. Eric Hedge


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2021 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
RARobert Amelard
Robert Amelard
EHEric Hedge
Eric Hedge
RHRichard L. Hughson
Richard L. Hughson
Oxygen consumption ( $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 ) provides established clinical and physiological indicators of cardiorespiratory function and exercise capacity. However, $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 monitoring is largely limited to specialized laboratory settings, making its widespread monitoring elusive. Here we investigate temporal prediction of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 from wearable sensors during cycle ergometer exercise using a temporal convolutional network (TCN). Cardiorespiratory signals were acquired from a smart shirt with integrated textile sensors alongside ground-truth $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 from a metabolic system on 22 young healthy adults. Participants performed one ramp-incremental and three pseudorandom binary sequence exercise protocols to assess a range of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 dynamics. A TCN model was developed using causal convolutions across an effective history length to model the time-dependent nature of $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 . Optimal history length was determined through minimum validation loss across hyperparameter values. The best performing model encoded 218 s history length (TCN-VO2 A), with 187, 97, and 76 s yielding <3% deviation from the optimal validation loss. TCN-VO2 A showed strong prediction accuracy (mean, 95% CI) across all exercise intensities (−22 ml min−1, [−262, 218]), spanning transitions from low–moderate (−23 ml min−1, [−250, 204]), low–high (14 ml min−1, [−252, 280]), ventilatory threshold–high (−49 ml min−1, [−274, 176]), and maximal (−32 ml min−1, [−261, 197]) exercise. Second-by-second classification of physical activity across 16,090 s of predicted $$\dot{\,{{\mbox{V}}}}{{{\mbox{O}}}}_{2}$$ V ̇ O 2 was able to discern between vigorous, moderate, and light activity with high accuracy (94.1%). This system enables quantitative aerobic activity monitoring in non-laboratory settings, when combined with tidal volume and heart rate reserve calibration, across a range of exercise intensities using wearable sensors for monitoring exercise prescription adherence and personal fitness.

26 January 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CLCederick Landry
Cederick Landry
EHEric Hedge
Eric Hedge
RHRichard L. Hughson
Richard L. Hughson
SPSean Peterson
Sean Peterson
Arash AramiArash Arami
Arash Arami
The objective is to develop a cuffless method that accurately estimates blood pressure (BP) during activities of daily living. User-specific nonlinear autoregressive models with exogenous inputs (NARX) are implemented using artificial neural networks to estimate the BP waveforms from electrocardiography and photoplethysmography signals. To broaden the range of BP in the training data, subjects followed a short procedure consisting of sitting, standing, walking, Valsalva maneuvers, and static handgrip exercises. The procedure was performed before and after a six-hour testing phase wherein five participants went about their normal daily living activities. Data were further collected at a four-month time point for two participants and again at six months for one of the two. The performance of three different NARX models was compared with three pulse arrival time (PAT) models. The NARX models demonstrate superior accuracy and correlation with “ground truth” systolic and diastolic BP measures compared to the PAT models and a clear advantage in estimating the large range of BP. Preliminary results show that the NARX models can accurately estimate BP even months apart from the training. Preliminary testing suggests that it is robust against variabilities due to sensor placement. This establishes a method for cuffless BP estimation during activities of daily living that can be used for continuous monitoring and acute hypotension and hypertension detection.

1 April 2023 in Journal of Applied Physiology
Verified
Journal Article
Closed access
EHEric Hedge
Eric Hedge
CMCarmelo J. Mastrandrea
Carmelo J. Mastrandrea
RHRichard L. Hughson
Richard L. Hughson
We report the complete time-course of cardiorespiratory fitness recovery back to baseline levels following 2 wk of head-down bed rest in 55- to 65-yr-old adults and found that multimodal training, consisting of high-intensity interval, aerobic and resistive exercises, performed throughout the 2 wk of head-down bed rest prevented reductions in cardiorespiratory fitness.

1 June 2023 in Journal of Applied Physiology
Verified
Journal Article
Closed access
EHEric Hedge
Eric Hedge
RARobert Amelard
Robert Amelard
RHRichard L. Hughson
Richard L. Hughson
Machine learning analysis of wearable sensor data with a sequential model, which utilized a receptive field of approximately 3 min to make instantaneous oxygen uptake estimations, accurately predicted oxygen uptake kinetics from moderate through to higher-intensity exercise. This innovation will enable nonintrusive cardiorespiratory monitoring over a wide range of exercise intensities encountered in vigorous training and competitive sports.

19 September 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CLCederick Landry
Cederick Landry
EHEric Hedge
Eric Hedge
RHRichard L. Hughson
Richard L. Hughson
SPSean Peterson
Sean Peterson
Arash AramiArash Arami
Arash Arami
Objective: To develop and evaluate an accurate method for cuffless blood pressure (BP) estimation during moderate- and heavy-intensity exercise. Methods: Twelve participants performed three cycling exercises: a ramp-incremental exercise to exhaustion, and moderate and heavy pseudorandom binary sequence exercises on an electronically braked cycle ergometer over the course of 21 minutes. Subject-specific and population-based nonlinear autoregressive models with exogenous inputs (NARX) were compared with feedforward artificial neural network (ANN) models and pulse arrival time (PAT) models. Results: Population-based NARX models, that is, trained on the three cycling exercise conditions for 11 participants and tested on the remaining participant (applying leave-one-subject-out cross-validation), performed better than the other models and showed good capability for estimating large changes in mean arterial pressure (MAP). The models were unable to track consistent decreases in BP during prolonged exercise caused by reduction in peripheral vascular resistance, since this information is apparently not encoded in the employed proxy physiological signals (electrocardiography and forehead PPG) used for BP estimation. Nevertheless, the population-based NARX model had an error standard deviation of 11.0 mmHg during the entire exercise window, which improved to 9.0 mmHg when the model was periodically calibrated every 7 minutes. Conclusion: Population-based NARX models can estimate BP during moderate- and heavy-intensity exercise but need periodic calibration to account for the change in vascular resistance during exertion. Significance: MAP can be continuously tracked during exercise using only wearable sensors, making monitoring exercise physiology more convenient and accessible.

1 August 2023 in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Verified
Journal Article
Closed access
CMCarmelo J. Mastrandrea
Carmelo J. Mastrandrea
EHEric Hedge
Eric Hedge
ARAndrew D. Robertson
Andrew D. Robertson
GHGeorge A. Heckman
George A. Heckman
JHJoanne Ho
Joanne Ho
RHRichard L. Hughson
Richard L. Hughson
Prolonged bedrest provokes orthostatic hypotension and intolerance of upright posture. Limited data are available on the cardiovascular responses of older adults to head-up tilt following bedrest, with no studies examining the potential benefits of exercise to mitigate intolerance in this age group. This randomized controlled trial of head-down bedrest (HDBR) in 55- to 65-yr-old men and women investigated if exercise could avert post-HDBR orthostatic intolerance. Twenty-two healthy older adults (11 female) underwent a strict 14-day HDBR and were assigned to either an exercise (EX) or control (CON) group. The exercise intervention included high-intensity, aerobic, and resistance exercises. Head-up tilt-testing to a maximum of 15 minutes was performed at baseline (Pre-Bedrest) and immediately after HDBR (R1), as well as 6 days (R6) and 4 weeks (R4wk) later. At Pre-Bedrest, three participants did not complete the full 15 minutes of tilt. At R1, 18 did not finish, with no difference in tilt end time between CON (422 ± 287 s) and EX (409 ± 346 s). No differences between CON and EX were observed at R6 or R4wk. At R1, just 1 participant self-terminated the test with symptoms, while 12 others reported symptoms only after physiological test termination criteria were reached. Finishers on R1 protected arterial pressure with higher total peripheral resistance relative to Pre-Bedrest. Cerebral blood velocity decreased linearly with reductions in arterial pressure, end-tidal CO2, and cardiac output. High-intensity interval exercise did not benefit post-HDBR orthostatic tolerance in older adults. Multiple factors were associated with the reduction in cerebral blood velocity leading to intolerance.