Hannah Joyce Coyle-Asbil

Ms. Hannah Joyce Coyle-Asbil


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HCHannah Joyce Coyle-Asbil
Hannah Joyce Coyle-Asbil
JHJanik Habegger
Janik Habegger
MOMichele Oliver
Michele Oliver
LVLori Ann Vallis
Lori Ann Vallis
The ActiGraph GT9X has been implemented in clinical trials to track physical activity and sleep. Given recent incidental findings from our laboratory, the overall aim of this study was to notify academic and clinical researchers of the idle sleep mode (ISM) and inertial measurement unit (IMU)’s interaction, as well as their subsequent effect on data acquisition. Investigations were undertaken using a hexapod robot to test the X, Y and Z sensing axes of the accelerometers. Seven GT9X were tested at frequencies ranging from 0.5 to 2 Hz. Testing was performed for three sets of setting parameters: Setting Parameter 1 (ISMONIMUON), Setting Parameter 2 (ISMOFFIMUON), Setting Parameter 3 (ISMONIMUOFF). The minimum, maximum and range of outputs were compared between the settings and frequencies. Findings indicated that Setting Parameters 1 and 2 were not significantly different, but both were significantly different from Setting Parameter 3. Upon inspection, it was discovered that the ISM was only active during Setting Parameter 3 testing, despite it being enabled in Setting Parameter 1. Researchers should be aware of this when conducting future research using the GT9X.

1 September 2024 in Physiological Measurement
Verified
Journal Article
Open access
HCHannah Joyce Coyle-Asbil
Hannah Joyce Coyle-Asbil
LBLukas Burk
Lukas Burk
MBMirko Brandes
Mirko Brandes
BBBerit Brandes
Berit Brandes
CBChristoph Buck
Christoph Buck
LVLori Ann Vallis
Lori Ann Vallis
Objective. This study aimed to develop convolutional neural networks (CNNs) models to predict the energy expenditure (EE) of children from raw accelerometer data. Additionally, this study sought to external validation of the CNN models in addition to the linear regression (LM), random forest (RF), and full connected neural network (FcNN) models published in Steenbock et al (2019 J. Meas. Phys. Behav. 2 94–102). Approach. Included in this study were 41 German children (3.0–6.99 years) for the training and internal validation who were equipped with GENEActiv, GT3X+, and activPAL accelerometers. The external validation dataset consisted of 39 Canadian children (3.0–5.99 years) that were equipped with OPAL, GT9X, GENEActiv, and GT3X+ accelerometers. EE was recorded simultaneously in both datasets using a portable metabolic unit. The protocols consisted of a semi-structured activities ranging from low to high intensities. The root mean square error (RMSE) values were calculated and used to evaluate model performances. Main results. (1) The CNNs outperformed the LM (13.17%–23.81% lower mean RMSE values), FcNN (8.13%–27.27% lower RMSE values) and the RF models (3.59%–18.84% lower RMSE values) in the internal dataset. (2) In contrast, it was found that when applied to the external Canadian dataset, the CNN models had consistently higher RMSE values compared to the LM, FcNN, and RF. Significance. Although CNNs can enhance EE prediction accuracy, their ability to generalize to new datasets and accelerometer brands/models, is more limited compared to LM, RF, and FcNN models.

10 February 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HCHannah Joyce Coyle-Asbil
Hannah Joyce Coyle-Asbil
JHJanik Habegger
Janik Habegger
MOMichele Oliver
Michele Oliver
LVLori Ann Vallis
Lori Ann Vallis
Recently, there has been a notable shift to increasingly more sedentary lifestyles, yet it remains unclear whether inexpensive accelerometers, such as those contained in Actigraph devices, can provide consistent measurements of low magnitude accelerations. This study sought to explore the ability of two Actigraph models to differentiate low frequency oscillations, in reference to higher-end accelerometers with the idle sleep mode disabled (ISM) (Part 1) and enabled (Part 2) in a controlled environment. Eight GT9X, fifteen wGT3X-BT and two higher-end accelerometers (Triaxial ICP) were mounted to a 6-degree of freedom robot, which introduced frequencies ranging from 0.5-2.0 Hz (Part 1) and 0.5-4.0 Hz (Part 2). To compare the models, the minimum, maximum and range of outputs were calculated for each of the frequencies. Part 1 revealed that the Actigraph monitors were able to detect low frequency oscillations; the captured output was similar across the different Actigraph models but was significantly greater than the higher-end devices. Part 2 demonstrated that amplitudes greater than the described 40 m g (0.392 m/s 2 ) threshold were required for the Actigraph monitors to wake up. This study demonstrates that the GT9X and wGT3X-BT Actigraph accelerometers can detect low magnitude movements when the ISM is disabled.

1 January 2026 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Open access
PDF file
JBJulia K. Baumgart
Julia K. Baumgart
HCHannah Joyce Coyle-Asbil
Hannah Joyce Coyle-Asbil
MKMichael Kebede
Michael Kebede
MOMelissa Otterbein
Melissa Otterbein
Martina ManciniMartina Mancini
Martina Mancini
LVLori Ann Vallis
Lori Ann Vallis
"Research for Equitable Health Outcomes: A Call for Diverse Participant Samples in Wearable Device Harmonization and Standardization Approaches" published on 29 Apr 2026 by Human Kinetics.

1 January 2024 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Closed access
PDF file
HCHannah Joyce Coyle-Asbil
Hannah Joyce Coyle-Asbil
Bernadette MurphyBernadette Murphy
Bernadette Murphy
LVLori Ann Vallis
Lori Ann Vallis
Accelerometers have been at the forefront of free-living activity capture for decades, and accordingly ActiGraph the largest distributor. Historically, limitations in data storage and battery power led to the use of summary metrics, which have been termed activity counts. Recently, ActiGraph publicly released their count-based algorithm, marking a notable development in the field. This study aimed to assess and compare activity counts generated through different processing techniques (ActiLife and open-source), filters that are available through ActiGraph count generation (normal- and low-frequency extension), and data from various ActiGraph models and GENEActiv devices. We evaluated ActiGraph GT3X+ (n = 8), ActiGraph wGT3X-BT (n = 10), ActiGraph GT9X (n = 8; primary and secondary sensors), OPAL (n = 6), and GENEActiv (n = 5), subjected to oscillations across their full dynamic range (0.005–8 G) using a multiaxis shaker table. Results indicated that the low-frequency extension produced significantly higher counts compared to the normal frequency across the devices and processing techniques. Notably, open-source counts (R and Python) were statistically equivalent to ActiLife-generated counts (p < .05) for the GT9X, wGT3X-BT, and the GT3X+. Overall, many of the counts generated by different ActiGraph models were statistically equivalent or had mean differences <5.03 counts. Conversely, the GENEActiv, OPAL, and GT9X secondary monitor exhibited significantly higher responses than the other ActiGraph models at higher frequencies with mean differences ranging from 55.50 to 104.91 counts. This study provides insights into accelerometer data processing methods and highlights the comparability of counts across different devices and techniques.

1 December 2022 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Closed access
PDF file
HCHannah Joyce Coyle-Asbil
Hannah Joyce Coyle-Asbil
ABAnuj Bhatia
Anuj Bhatia
ALAndrew Lim
Andrew Lim
MSMandeep Singh
Mandeep Singh
Individuals suffering from neuropathic pain commonly report issues associated with sleep. To measure sleep in this population, researchers have used actigraphy. Historically, actigraphy data have been analyzed in the form of counts; however, due to the proprietary nature, many opt to quantify data in its raw form. Various processing techniques exist to accomplish this; however, it remains unclear how they compare to one another. This study sought to compare sleep measures derived using the GGIR R package versus the GENEActiv (GA) R Markdown tool in a neuropathic pain population. It was hypothesized that the processing techniques would yield significantly different sleep outcomes. One hundred and twelve individuals (mean age = 52.72 ± 13.01 years; 60 M) with neuropathic pain in their back and/or lower limbs were included. While simultaneously undergoing spinal cord stimulation, actigraphy devices were worn on the wrist for a minimum of 7 days (GA; 50 Hz). Upon completing the protocol, sleep outcome measures were calculated using (a) the GGIR R package and (b) the GA R Markdown tool. To compare these algorithms, paired-samples t tests and Bland–Altman plots were used to compare the total sleep time, sleep efficiency, wake after sleep onset, sleep onset time, and rise times. According to the paired-samples t test, the GA R Markdown yielded lower total sleep time and sleep efficiency and a greater wake after sleep onset, compared with the GGIR package. Furthermore, later sleep onset times and earlier rise times were reported by the GGIR package compared with the GA R Markdown.