Federica Caselli

Dr. Federica Caselli

Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, 00133 Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Carlos HonradoCarlos Honrado
Carlos Honrado
PBPaolo Bisegna
Paolo Bisegna
NSNathan Swami
Nathan Swami
Federica CaselliFederica Caselli
Federica Caselli
The biophysical analysis of single-cells by microfluidic impedance cytometry is emerging as a label-free and high-throughput means to stratify the heterogeneity of cellular systems based on their electrophysiology. Emerging applications range from fundamental life-science and drug assessment research to point-of-care diagnostics and precision medicine. Recently, novel chip designs and data analytic strategies are laying the foundation for multiparametric cell characterization and subpopulation distinction, which are essential to understand biological function, follow disease progression and monitor cell behaviour in microsystems. In this tutorial review, we present a comparative survey of the approaches to elucidate cellular and subcellular features from impedance cytometry data, covering the related subjects of device design, data analytics (i.e., signal processing, dielectric modelling, population clustering), and phenotyping applications. We give special emphasis to the exciting recent developments of the technique (timeframe 2017–2020) and provide our perspective on future challenges and directions. Its synergistic application with microfluidic separation, sensor science and machine learning can form an essential toolkit for label-free quantification and isolation of subpopulations to stratify heterogeneous biosystems.

28 May 2008 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Arianna MencattiniArianna Mencattini
Arianna Mencattini
MSMarcello Salmeri
Marcello Salmeri
RLRoberto Lojacono
Roberto Lojacono
MFManuela Frigerio
Manuela Frigerio
Federica CaselliFederica Caselli
Federica Caselli
Mammography is the most effective method for the early detection of breast diseases. However, the typical diagnostic signs such as microcalcifications and masses are difficult to detect because mammograms are low-contrast and noisy images. In this paper, a novel algorithm for image denoising and enhancement based on dyadic wavelet processing is proposed. The denoising phase is based on a local iterative noise variance estimation. Moreover, in the case of microcalcifications, we propose an adaptive tuning of enhancement degree at different wavelet scales, whereas in the case of mass detection, we developed a new segmentation method combining dyadic wavelet information with mathematical morphology. The innovative approach consists of using the same algorithmic core for processing images to detect both microcalcifications and masses. The proposed algorithm has been tested on a large number of clinical images, comparing the results with those obtained by several other algorithms proposed in the literature through both analytical indexes and the opinions of radiologists. Through preliminary tests, the method seems to meaningfully improve the diagnosis in the early breast cancer detection with respect to other approaches.

9 February 2017 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
ANAdele De Ninno
Adele De Ninno
VEVito Errico
Vito Errico
FBFrancesca Romana Bertani
Francesca Romana Bertani
LBLuca Businaro
Luca Businaro
PBPaolo Bisegna
Paolo Bisegna
Federica CaselliFederica Caselli
Federica Caselli
Microfluidic impedance cytometry offers a simple non-invasive method for single-cell analysis. Coplanar electrode chips are especially attractive due to ease of fabrication, yielding miniaturized, reproducible, and ultimately low-cost devices. However, their accuracy is challenged by the dependence of the measured signal on particle trajectory within the interrogation volume, that manifests itself as an error in the estimated particle size, unless any kind of focusing system is used. In this paper, we present an original five-electrode coplanar chip enabling accurate particle sizing without the need for focusing. The chip layout is designed to provide a peculiar signal shape from which a new metric correlating with particle trajectory can be extracted. This metric is exploited to correct the estimated size of polystyrene beads of 5.2, 6 and 7 μm nominal diameter, reaching coefficient of variations lower than the manufacturers' quoted values. The potential impact of the proposed device in the field of life sciences is demonstrated with an application to Saccharomyces cerevisiae yeast.

18 March 2020 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
Carlos HonradoCarlos Honrado
Carlos Honrado
JMJohn S McGrath
John S McGrath
RRRiccardo Reale
Riccardo Reale
PBPaolo Bisegna
Paolo Bisegna
NSNathan Swami
Nathan Swami
Federica CaselliFederica Caselli
Federica Caselli

20 May 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DSDaniel Spencer
Daniel Spencer
Federica CaselliFederica Caselli
Federica Caselli
PBPaolo Bisegna
Paolo Bisegna
HMHywel Morgan
Hywel Morgan
A new microfluidic impedance cytometer chip is demonstrated, giving high quality impedance signals without the need for any particle focusing.

30 May 2014 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MSMarjan Shaker
Marjan Shaker
LCL. Colella
L. Colella
Federica CaselliFederica Caselli
Federica Caselli
PBP. Bisegna
P. Bisegna
PRP. Renaud
P. Renaud
Cell shape is a fundamental biological feature, providing specific information about physiological or pathological cellular conditions. Most of the state-of-the-art microfluidic cytometers, however, only allow simple cell analysis, including viability studies, cell counting and sorting. In this work, we present a non-invasive, label-free device capable of single cell morphology discrimination in continuous flow. The device is based on the principle of liquid electrodes, fabricated in a cross configuration around a sensing zone. This arrangement allows measurement of cell impedance along orthogonal orientations and extraction of an index describing cell shape anisotropy. By adding prior to the sensing volume a series of lateral liquid electrodes, the particle stream was focused toward the channel midline and each cell was oriented in a specific direction before shape sensing. We demonstrate the proof of concept by performing spherical and elongated particle discrimination. As an application, we show that the shape changes experienced during cell division can be monitored and characterized. In particular, budding yeasts at different stages of the mitotic cycle were identified by extracting their anisotropy index.