4 February 2020 in ACS Sensors
20 May 2016 in Lab on a Chip
A new microfluidic impedance cytometer chip is demonstrated, giving high quality impedance signals without the need for any particle focusing.
28 February 2011 in Lab on a Chip
Single cell impedance cytometry is a label-free electrical analysis method that requires minimal sample preparation and has been used to count and discriminate cells on the basis of their impedance properties. This paper shows experimental and numerically simulated impedance signals for test particles (6 μm diameter polystyrene) flowing through a microfluidic channel. The variation of impedance signal with particle position is mapped using numerical simulation and these results match closely with experimental data. We demonstrate that for a nominal 40 μm × 40 μm channel, the impedance signal is independent of position over the majority of the channel area, but shows large experimentally verifiable variation at extreme positions. The parabolic flow profile in the channel ensures that most of the sample flows through the area of uniform signal. At high flow rates inertial focusing is observed; the particles flow in equal numbers through two equilibrium positions reducing the coefficient of variance (CV) in the impedance signals to negligible values.
1 June 2017 in Scientific Reports
At present, there are few technologies which enable the detection, identification and viability analysis of protozoan pathogens including Cryptosporidium and/or Giardia at the single (oo)cyst level. We report the use of Microfluidic Impedance Cytometry (MIC) to characterise the AC electrical (impedance) properties of single parasites and demonstrate rapid discrimination based on viability and species. Specifically, MIC was used to identify live and inactive C. parvum oocysts with over 90% certainty, whilst also detecting damaged and/or excysted oocysts. Furthermore, discrimination of Cryptosporidium parvum, Cryptosporidium muris and Giardia lamblia, with over 92% certainty was achieved. Enumeration and identification of (oo)cysts can be achieved in a few minutes, which offers a reduction in identification time and labour demands when compared to existing detection methods.
1 November 2014 in Biomicrofluidics
The dielectric properties of tumour cells are known to differ from normal blood cells, and this difference can be exploited for label-free separation of cells. Conventional measurement techniques are slow and cannot identify rare circulating tumour cells (CTCs) in a realistic timeframe. We use high throughput single cell microfluidic impedance cytometry to measure the dielectric properties of the MCF7 tumour cell line (representative of CTCs), both as pure populations and mixed with whole blood. The data show that the MCF7 cells have a large membrane capacitance and size, enabling clear discrimination from all other leukocytes. Impedance analysis is used to follow changes in cell viability when cells are kept in suspension, a process which can be understood from modelling time-dependent changes in the dielectric properties (predominantly membrane conductivity) of the cells. Impedance cytometry is used to enumerate low numbers of MCF7 cells spiked into whole blood. Chemical lysis is commonly used to remove the abundant erythrocytes, and it is shown that this process does not alter the MCF7 cell count or change their dielectric properties. Combining impedance cytometry with magnetic bead based antibody enrichment enables MCF7 cells to be detected down to 100 MCF7 cells in 1 ml whole blood, a log 3.5 enrichment and a mean recovery of 92%. Microfluidic impedance cytometry could be easily integrated within complex cell separation systems for identification and enumeration of specific cell types, providing a fast in-line single cell characterisation method.
9 January 2019 in Lab on a Chip
Cell sorting using label-free microfluidic approaches offer significant promise for skeletal stem cell enrichment from human bone marrow.