Shang-Chih Lin

Prof. Dr. Shang-Chih Lin

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2023 in Polymers
Verified
Journal Article
Open access
PDF file
SPSANDEEP KUMAR PARAL
SANDEEP KUMAR PARAL
DLDing-Zheng Lin
Ding-Zheng Lin
YCYih-Lin Cheng
Yih-Lin Cheng
SLShang-Chih Lin
Shang-Chih Lin
Jeng-Ywan JengJeng-Ywan Jeng
Jeng-Ywan Jeng
Vat photopolymerization (VPP) is an effective additive manufacturing (AM) process known for its high dimensional accuracy and excellent surface finish. It employs vector scanning and mask projection techniques to cure photopolymer resin at a specific wavelength. Among the mask projection methods, digital light processing (DLP) and liquid crystal display (LCD) VPP have gained significant popularity in various industries. To upgrade DLP and LCC VPP into a high-speed process, increasing both the printing speed and projection area in terms of the volumetric print rate is crucial. However, challenges arise, such as the high separation force between the cured part and the interface and a longer resin refilling time. Additionally, the divergence of the light-emitting diode (LED) makes controlling the irradiance homogeneity of large-sized LCD panels difficult, while low transmission rates of near ultraviolet (NUV) impact the processing time of LCD VPP. Furthermore, limitations in light intensity and fixed pixel ratios of digital micromirror devices (DMDs) constrain the increase in the projection area of DLP VPP. This paper identifies these critical issues and provides detailed reviews of available solutions, aiming to guide future research towards developing a more productive and cost-effective high-speed VPP in terms of the high volumetric print rate.

8 May 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JYJesse Chieh-Szu Yang
Jesse Chieh-Szu Yang
CCCheng-Fong Chen
Cheng-Fong Chen
CLChu-An Luo
Chu-An Luo
MCMing-Chau Chang
Ming-Chau Chang
OLOscar K. Lee
Oscar K. Lee
SLShang-Chih Lin
Shang-Chih Lin
Purpose. High tibial osteotomy (HTO) has been adopted as an effective surgery for medial degeneration of the osteoarthritis (OA) knee. However, satisfactory outcomes necessitate the precise creation and distraction of osteotomized wedges and the use of intraoperative X-ray images to continually monitor the wedge-related manipulation. Thus HTO is highly technique-demanding and has a high radiation exposure. We report a patient-specific instrument (PSI) guide for the precise creation and distraction of HTO wedge. Methods. This study first parameterized five HTO procedures to serve as a design rationale for an innovative PSI guide. Preoperative X-ray and computed tomography- (CT-) scanning images were used to design and fabricate PSI guides for clinical use. The weight-bearing line (WBL) of the ten patients was shifted to the Fujisawa’s point and instrumented using the TomoFix system. The radiological results of the PSI-guided HTO surgery were evaluated by the WBL percentage and tibial slope. Results. All patients consistently showed an increased range of motion and a decrease in pain and discomfort at about three-month follow-up. This study demonstrates the satisfactory accuracy of the WBL adjustment and tibial slope maintenance after HTO with PSI guide. For all patients, the average pre- and postoperative WBL are, respectively, 14.2% and 60.2%, while the tibial slopes are 9.9 and 10.1 degrees. The standard deviations are 2.78 and 0.36, respectively, in postoperative WBL and tibial slope. The relative errors of the pre- and postoperative WBL percentage and tibial slope averaged 4.9% and 4.1%, respectively. Conclusion. Instead of using navigator systems, this study integrated 2D and 3D preoperative planning to create a PSI guide that could most likely render the outcomes close to the planning. The PSI guide is a precise procedure that is time-saving, radiation-reducing, and relatively easy to use. Precise osteotomy and good short-term results were achieved with the PSI guide.

6 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
GSGul Jamil Shah
Gul Jamil Shah
Aamer NazirAamer Nazir
Aamer Nazir
SLShang-Chih Lin
Shang-Chih Lin
Jeng-Ywan JengJeng-Ywan Jeng
Jeng-Ywan Jeng
Additive Manufacturing (AM) is rapidly evolving due to its unlimited design freedom to fabricate complex and intricate light-weight geometries with the use of lattice structure that have potential applications including construction, aerospace and biomedical applications, where mechanical properties are the prime focus. Buckling instability in lattice structures is one of the main failure mechanisms that can lead to major failure in structural applications that are subjected to compressive loads, but it has yet to be fully explored. This study aims to investigate the effect of surface-based lattice structure topologies and structured column height on the critical buckling load of lattice structured columns. Four different triply periodic minimal surface (TPMS) lattice topologies were selected and three design configurations (unit cells in x, y, z axis), i.e., 2 × 2 × 4, 2 × 2 × 8 and 2 × 2 × 16 column, for each structure were designed followed by printing using HP MultiJet fusion. Uni-axial compression testing was performed to study the variation in critical buckling load due to change in unit cell topology and column height. The results revealed that the structured column possessing Diamond structures shows the highest critical buckling load followed by Neovius and Gyroid structures, whereas the Schwarz-P unit cell showed least resistance to buckling among the unit cells analyzed in this study. In addition to that, the Diamond design showed a uniform decrease in critical buckling load with a column height maximum of 5193 N, which makes it better for applications in which the column’s height is relatively higher while the Schwarz-P design showed advantages for low height column maximum of 2271 N. Overall, the variations of unit cell morphologies greatly affect the critical buckling load and permits the researchers to select different lattice structures for various applications as per load/stiffness requirement with different height and dimensions. Experimental results were validated by finite element analysis (FEA), which showed same patterns of buckling while the numerical values of critical buckling load show the variation to be up to 10%.

1 February 2013 in Indian Journal of Orthopaedics
Verified
Journal Article
Open access
PDF file
CLChe-Wei Liu
Che-Wei Liu
SLShang-Chih Lin
Shang-Chih Lin
SCShih-Youeng Chuang
Shih-Youeng Chuang
JCJen-Huei Chang
Jen-Huei Chang
CWChia-Chun Wu
Chia-Chun Wu
LLLeou-Chyr Lin
Leou-Chyr Lin
Background: Arthroscopic debridement with continuous irrigation system was used with success in treating infective arthritis. We evaluated the effectiveness of arthroscopic debridement coupled with antibiotic continuous irrigation system in acute presentation of late infected total knee arthroplasty. Materials and Methods: We performed a retrospective review of medical record of patients with acute presentation of late infected total knee arthroplasty who were treated by arthroscopic debridement coupled with continuous postoperative antibiotic irrigation system. Results: Seventeen patients were included in our study. 15 (88%) patients preserved their total knee prosthesis at mean of followup of 27.5 months (range, 14-28 months). Two (12%) patients failed arthroscopic protocol and finally needed two stages revision. Our study showed an 88% prosthesis retention rate in patients with acute presentation of late prosthetic knee infection. No complication was associated with use of antibiotic irrigation system. Conclusion: Arthroscopic debridement combined with continuous antibiotic irrigation and suction is an effective treatment for patients with acute presentation of late infected total knee arthroplasty.

29 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
YHYeabsra Mekdim Hailu
Yeabsra Mekdim Hailu
Aamer NazirAamer Nazir
Aamer Nazir
SLShang-Chih Lin
Shang-Chih Lin
Jeng-Ywan JengJeng-Ywan Jeng
Jeng-Ywan Jeng
Functionally graded lattice structures have attracted much attention in engineering due to their excellent mechanical performance resulting from their optimized and application-specific properties. These structures are inspired by nature and are important for a lightweight yet efficient and optimal functionality. They have enhanced mechanical properties over the uniform density counterparts because of their graded design, making them preferable for many applications. Several studies were carried out to investigate the mechanical properties of graded density lattice structures subjected to different types of loadings mainly related to tensile, compression, and fatigue responses. In applications related to biomedical, automotive, and aerospace sectors, dynamic bending and rotational stresses are critical load components. Therefore, the study of torsional properties of functionally gradient lattice structures will contribute to a better implementation of lattice structures in several sectors. In this study, several functionally gradient triply periodic minimal surfaces structures and strut-based lattice structures were designed in cylindrical shapes having 40% relative density. The HP Multi Jet Fusion 4200 3D printer was used to fabricate all specimens for the experimental study. A torsional experiment until the failure of each structure was conducted to investigate properties of the lattice structures such as torsional stiffness, energy absorption, and failure characteristics. The results showed that the stiffness and energy absorption of structures can be improved by an effective material distribution that corresponds to the stress concentration due to torsional load. The TPMS based functionally gradient design showed a 35% increase in torsional stiffness and 15% increase in the ultimate shear strength compared to their uniform counterparts. In addition, results also revealed that an effective material distribution affects the failure mechanism of the lattice structures and delays the plastic deformation, increasing their resistance to torsional loads.

14 July 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CLChe-Wei Liu
Che-Wei Liu
LWLu-Lin Wang
Lu-Lin Wang
YXYu-Kun Xu
Yu-Kun Xu
CCChun-Ming Chen
Chun-Ming Chen
JWJian-Cyuan Wang
Jian-Cyuan Wang
SLShang-Chih Lin
Shang-Chih Lin
Background: Two types of screw trajectories are commonly used in lumbar surgery. Both traditional trajectory (TT) and cortical bone trajectory (CBT) were shown to provide equivalent pull-out strengths of a screw. CBT utilizing a laterally-directed trajectory engaging only cortical bone in the pedicle is widely used in minimal invasive spine posterior fusion surgery. It has been demonstrated that CBT exerts a lower likelihood of violating the facet joint, and superior pull-out strength than the TT screws, especially in osteoporotic vertebral body. No design yet to apply this trajectory to dynamic fixation. To evaluate kinetic and kinematic behavior in both static and dynamic CBT fixation a finite element study was designed. This study aimed to simulate the biomechanics of CBT-based dynamic system for an evaluation of CBT dynamization. Methods: A validated nonlinearly lumbosacral finite-element model was used to simulate four variations of screw fixation. Responses of both implant (screw stress) and tissues (disc motion, disc stress, and facet force) at the upper adjacent (L3-L4) and fixed (L4-L5) segments were used as the evaluation indices. Flexion, extension, bending, and rotation of both TT and CBT screws were simulated in this study for comparison. Results: The results showed that the TT static was the most effective stabilizer to the L4-L5 segment, followed by CBT static, TT dynamic, and the CBT dynamic, which was the least effective. Dynamization of the TT and CBT fixators decreased stability of the fixed segment and alleviate adjacent segment stress compensation. The 3.5-mm diameter CBT screw deteriorated stress distribution and rendered it vulnerable to bone-screw loosening and fatigue cracking. Conclusions: Modeling the effects of TT and CBT fixation in a full lumbosacral model suggest that dynamic TT provide slightly superior stability compared with dynamic CBT especially in bending and rotation. In dynamic CBT design, large diameter screws might avoid issues with loosening and cracking.