Coatings based on calcium phosphate with thicknesses of 0.5 and 2 μm were obtained by high-frequency magnetron sputtering on NiTi substrates in an argon atmosphere. The coating was characterized using X-ray diffraction, scanning electron microscopy, atomic force microscopy, and in vitro cytocompatibility and bioactivity studies. A biphasic coating of tricalcium phosphate (Ca3(PO4)2) and hydroxyapatite (Ca10(PO4)6(OH)2) with a 100% degree of crystallinity was formed on the surface. The layer enriched in calcium, phosphorus, and oxygen was observed using scanning electron microscopy and energy-dispersive X-ray spectroscopy. Scanning electron microscopy showed that the surface structure is homogeneous without visible defects. The 2 µm thick coating obtained by sputtering with a deposition time of 4 h and a deposition rate of 0.43 µm/h is uniform, contains the highest amount of the calcium phosphate phase, and is most suitable for the faster growth of cells and accelerated formation of apatite layers. Samples with calcium phosphate coatings do not cause hemolysis and have a low cytotoxicity index. The results of immersion in a solution simulating body fluid show that NiTi with the biphasic coating promotes apatite growth, which is beneficial for biological activity.
Hydroxyapatite coatings were deposited for 1, 2, and 3 h on NiTi substrates using plasma-assisted radio frequency sputtering. The matrix consisted of NiTi B2 and NiTi B19’ phases and Ti2Ni, Ni3Ti, and Ni4Ti3 intermetallic compounds. The surface coating was monoclinic hydroxyapatite. Increasing the deposition time to 3 h made it possible to form a dense hydroxyapatite layer without visible defects. The phase contrast maps showed that the coating consisted of round grains of different fractions, with the smallest grains in the sample deposited for 3 h. The wettability tests showed that the coating deposited for 3 h had the highest surface energy, reflected in the proliferation density of the MCF-7 cell line.
Introduction. Magnesium and its alloys are used as biodegradable bone implants due to their high biocompatibility, however, the problem of use is rapid biodegradation with loss of strength.The purpose of the study. Experimental evaluation of bioresorbable Mg-Ca-Zn alloy implants in vitro and in bone tissue in vivo, in order to determine the optimal rate of biodegradation, biocompatibility and reparative response of bone tissue.Materials and methods. Samples from the obtained Mg-Ca-Zn alloy were coated in a microarc oxidation bath (MDO), and to further determine the optimal phase composition and surface properties, the samples were kept in an electrolyte. The biodegradation of implants was assessed by the loss of mass of samples in vitro, and the release of gas into bone tissue in vivo, and the biocompatibility and reparative response of bone tissue density.Results. All Mg-Ca-Zn coated samples show reduced weight loss compared to the uncoated sample. Magnesium samples with a 20-minute exposure in electrolyte, in the context of its application in anatomically unloaded areas, showed the optimal rate of biodegradation, biocompatibility and reparative response of bone tissue.Discussion. In our study using the microarc oxidation for control the corrosion resistance samples of magnesium alloy shows good biocompatibility and low corrosion rate. We found 5-fold increase in corrosion resistance in coated implants, compared with uncoated samples.Сonclusion. The results of an experimental evaluation of bioresorbable Mg-Ca-Zn alloy implants in vitro and in bone tissue in vivo showed that Mg-Ca-Zn coated samples demonstrate low weight loss during biodegradation, with minimal gas release into the bone.
11 April 2024 in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
BACKGROUND: The relevance of this study was supported by the increasing number of infectious complications of bone augmentation in children and adults. Currently, porous titanium nickelide alloys are among the most preferred materials used in bone plasty. Despite the observable advantages of porous nickelide titanium alloys in terms of biochemical and biomechanical compatibility with the body, research on the antibacterial activity of alloys is ongoing to counter the development of infections at the implant–biological tissue border. AIM: To perform an experimental study of the biocompatible antibacterial surface in porous titanium nickelide alloys with the addition of silver nanoparticles. MATERIALS AND METHODS: Titanium nickelide alloys with 62% porosity were obtained using the self-propagating high-temperature synthesis method from nickel, titanium, and nanosilver powders at concentrations of 0.2 at.% Ag, 0.5 at.% Ag, and 1.0 at.% Ag, respectively. The experiment was conducted on nine sexually mature female white laboratory rats. They were divided into three groups, with three rats each. All animals were implanted with titanium nickelide along with porous granules of silver additives. The first group was the control, the second received 0.2 at.% silver, and the third received 0.5% silver. The standard method of incubating Staphylococcus epidermidis in liquid broth in the presence of the studied images was used to determine bactericidal activity, followed by seeding on solid media and counting colonies. RESULTS: The antibacterial effect of the samples on S. epidermidis gradually increased with increasing silver concentration. The significance of the differences between the experiment and control was confirmed by Student’s criterion p 0.005, whereas the sample without silver nanoparticles and the control do not differ significantly. Thus, these alloys may have bioactive properties because they contain silver nanoparticles. An alloy with a silver concentration of 0.5 at.% Ag showed the best antibacterial activity to S. epidermidis. In the clinical evaluation of the results of the experimental study, purulent inflammatory complications were not observed in all animals at all times. On day 75, the animals underwent computed tomography, which showed good occupancy of the bone defect and absence of a dystrophic effect on the area where the bone and soft tissue are in contact with the material. CONCLUSIONS: If the concentration of silver nanoparticles is increased up to 0.5 at%, the antibacterial activity and cytocompatibility of the implant also increase. Clinical experimental evaluation in all groups of animals showed that osteointegration of alloys with 0.5 at.% Ag begins immediately after implantation and is completed 2 weeks earlier than that in the remaining groups.
5 April 2024 in Siberian Journal of Clinical and Experimental Medicine
Introduction. Porous TiNi alloys are widely used in medicine as osteoreplacement implants due to their unique properties of superelasticity and biocompatibility, but their clinical use is severely limited by time-consuming manual fabrication and the inability to create precise geometries. Reconstructive surgery for the replacement of bone defects requires biocompatible endoprostheses of individual shape and complex geometry. The use of porous 3D-TiNi implants can be a solution to many problems in traumatology and bone oncology.Aim: To evaluate the possibility of using porous 3D-TiNi implants in osteoplastic surgery based on a study of the structure and biocompatibility of the material under in vivo conditions.Material and Methods. Porous samples in the form of cones and a single implant for maxillofacial surgery were prepared from TiNi powder by selective laser melting. To print an individual implant for maxillofacial surgery, the personal data of the patient at the Oncology Research Institute were used. The macrostructure, elemental and phase composition of porous titanium nickelide samples were investigated using scanning microscopy and X-ray diffraction analysis. The biocompatibility of porous cone-shaped samples was evaluated in vivo using guinea pigs whose condition was analysed by CT scanning.Results. Structural studies of porous titanium nickelide samples showed that selective laser melting can be used to obtain a continuous porous structure with strong contact bridges between particles of a three-phase powder. In vivo testing of the cone-shaped implants showed no local inflammatory changes, rejection or deformation of the hind limb axes of the experimental animals. The basic feasibility of fabricating a custom implant of complex geometry from TiNi powder using selective laser melting according to a patient’s MSCT data was demonstrated.Conclusions. Porous 3D-TiNi implants obtained by selective laser melting showed high biocompatibility under in vivo conditions. An experimental study confirmed the efficacy and ease of use of 3D TiNi implants, their excellent self-fixation in bone tissue, and bone tissue augmentation at the interface with the implant. The macrostructure, chemical and phase composition of the implant material was found to be close to traditional porous TiNi alloys. It was shown that the method of selective laser melting makes it possible to create complex geometric defects in bone tissue from TiNi.