Introduction. Magnesium and its alloys are used as biodegradable bone implants due to their high biocompatibility, however, the problem of use is rapid biodegradation with loss of strength.The purpose of the study. Experimental evaluation of bioresorbable Mg-Ca-Zn alloy implants in vitro and in bone tissue in vivo, in order to determine the optimal rate of biodegradation, biocompatibility and reparative response of bone tissue.Materials and methods. Samples from the obtained Mg-Ca-Zn alloy were coated in a microarc oxidation bath (MDO), and to further determine the optimal phase composition and surface properties, the samples were kept in an electrolyte. The biodegradation of implants was assessed by the loss of mass of samples in vitro, and the release of gas into bone tissue in vivo, and the biocompatibility and reparative response of bone tissue density.Results. All Mg-Ca-Zn coated samples show reduced weight loss compared to the uncoated sample. Magnesium samples with a 20-minute exposure in electrolyte, in the context of its application in anatomically unloaded areas, showed the optimal rate of biodegradation, biocompatibility and reparative response of bone tissue.Discussion. In our study using the microarc oxidation for control the corrosion resistance samples of magnesium alloy shows good biocompatibility and low corrosion rate. We found 5-fold increase in corrosion resistance in coated implants, compared with uncoated samples.Сonclusion. The results of an experimental evaluation of bioresorbable Mg-Ca-Zn alloy implants in vitro and in bone tissue in vivo showed that Mg-Ca-Zn coated samples demonstrate low weight loss during biodegradation, with minimal gas release into the bone.
5 April 2024 in Siberian Journal of Clinical and Experimental Medicine
Introduction. Porous TiNi alloys are widely used in medicine as osteoreplacement implants due to their unique properties of superelasticity and biocompatibility, but their clinical use is severely limited by time-consuming manual fabrication and the inability to create precise geometries. Reconstructive surgery for the replacement of bone defects requires biocompatible endoprostheses of individual shape and complex geometry. The use of porous 3D-TiNi implants can be a solution to many problems in traumatology and bone oncology.Aim: To evaluate the possibility of using porous 3D-TiNi implants in osteoplastic surgery based on a study of the structure and biocompatibility of the material under in vivo conditions.Material and Methods. Porous samples in the form of cones and a single implant for maxillofacial surgery were prepared from TiNi powder by selective laser melting. To print an individual implant for maxillofacial surgery, the personal data of the patient at the Oncology Research Institute were used. The macrostructure, elemental and phase composition of porous titanium nickelide samples were investigated using scanning microscopy and X-ray diffraction analysis. The biocompatibility of porous cone-shaped samples was evaluated in vivo using guinea pigs whose condition was analysed by CT scanning.Results. Structural studies of porous titanium nickelide samples showed that selective laser melting can be used to obtain a continuous porous structure with strong contact bridges between particles of a three-phase powder. In vivo testing of the cone-shaped implants showed no local inflammatory changes, rejection or deformation of the hind limb axes of the experimental animals. The basic feasibility of fabricating a custom implant of complex geometry from TiNi powder using selective laser melting according to a patient’s MSCT data was demonstrated.Conclusions. Porous 3D-TiNi implants obtained by selective laser melting showed high biocompatibility under in vivo conditions. An experimental study confirmed the efficacy and ease of use of 3D TiNi implants, their excellent self-fixation in bone tissue, and bone tissue augmentation at the interface with the implant. The macrostructure, chemical and phase composition of the implant material was found to be close to traditional porous TiNi alloys. It was shown that the method of selective laser melting makes it possible to create complex geometric defects in bone tissue from TiNi.
The review to systematize scientific literature data on the topic of post-traumatic flatfoot has been conducted. We applied search filters to find literature in the text summarization domain from eLibrary, pubMED, Scopus. The arches of the foot, formed by the calcaneal bone at the back and two heads of the metatarsal bones: I and V. Post-traumatic flat feet occurs after fractures of the calcaneus or metatarsal bones. Fractures of the metatarsal bones associated with post-traumatic flatfoot in the outcome of the disease. The literature review indicates clinically significant correlations between fractures of the foot bones and occurrence of post-traumatic flatfoot. Most of the material presented on the influence of calcaneal fractures on the occurrence of post-traumatic flatfoot with a direct correlation. There are sources on the correlation between metatarsal bone fractures and post-traumatic flatfoot. In the studies, the authors link metatarsal fractures and flat feet. They also note a direct correlation between the disease and its complications. The literature review show correlations between fractures of calcaneus or metatarsal bones and occurrence of post-traumatic flatfoot.Research in the field of fractures of the bones of the foot and post-traumatic flat feet, is relevant now and requires further scientific research.There was also a small amount of material on studies of post-traumatic flatfoot in children.
29 June 2025 in Russian Journal of Pediatric Surgery
BACKGROUND: Currently, restoration of bone tissue damaged in case of injuries and surgical interventions remains an urgent problem in medicine. The combination of titanium nickelide (NT) with silver seems promising in terms of reducing the activity of the inflammatory process, speedy regeneration and restoration of damaged bone tissue function. AIMS: to determine the possible acute systemic and subacute toxicity of an innovative titanium nickelide alloy with silver in an experiment on laboratory animals. METHODS: the study of acute systemic toxicity was carried out in white outbred mice (17-23g). The supernatant liquid of NT alloy powder with the addition of 0.5% silver on a water basis was injected into the tail vein (n=10), on a non-aqueous basis - intraperitoneally (n=10), in a volume of 50 ml/kg. The corresponding medium was used as a control (n=10). To identify subacute toxicity, samples were sewn into the thigh muscles of Wistar rats (250-320g): three experimental groups (n=10) - NT with 0.3% silver, 0.5% silver and 0% silver. The fourth group (n=10) - control (wound modeling without powder injection). After 28 days, the animals were removed from the experiment, and hematological and biochemical blood tests were performed. RESULTS: no animal deaths or adverse clinical signs were recorded following the acute systemic toxicity test. The number of erythrocytes in the blood of experimental animals after intramuscular administration of NT with the addition of 0.5% silver was significantly higher than in control rats, remaining within the normal range for this indicator. A moderate decrease in platelet levels in animals treated with NT with 0.3% silver may be due to the presence of anti-inflammatory activity of the sample. The urea concentration in the blood of animals after suturing NT with 0.5% silver was significantly lower than in control animals (p = 0.019), which may be due to an increase in silver concentration of the alloy and requires further study. CONCLUSIONS: new materials based on titanium nickelide with the addition of silver do not have acute systemic or subacute toxicity. Keywords: titanium nickelide, silver, experimental animals, toxicity.
Introduction. Biomedical implants in present time are under active research. Titanium nickelide (NiTi) is alloy widely uses for its properties. Despite the advantages of NiTi, its use is limited by the potential risks associated with abnormal tissue reaction. Therefore, significant efforts are being made to improve the biocompatibility of NiTi and reduce its toxicity.The purpose of the study is to research potential changes in hematological parameters, to assess acute, subacute and chronic toxicity that may be associated with NiTi-silver (Ag) alloys.Materials and methods. The study was conducted as part of an open, randomized, controlled experiment lasting 9 months. The object of study was samples of NiTi powder with Ag addition. NiTi powder without the addition of Ag was used as a control. The study of acute, subacute, subchronic, chronic toxicity and hematological profile in particular, were conducted.Results. When assessing the condition of laboratory animals after conducting a test to determine acute systemic toxicity, animal deaths and adverse clinical signs were not recorded in any group of animals during the entire observation period. To study the potential for subacute toxicity, a general blood test was performed, and the potential anti-inflammatory activity of the implant was noted.Conclusion. Assessment of acute, subacute, subchronic and chronic toxicity of NiTi revealed no signs of animal death or pronounced clinical symptoms indicating a general toxic effect after surgery. As a result of the dynamic assessment parameters of the blood, no changes characteristic of the toxic effect of the alloy on hematopoiesis were detected.
26 December 2025 in Russian Journal of Pediatric Surgery, Anesthesia and Intensive Care
BACKGROUND: Restoration of bone tissue damaged as a result of trauma remains a relevant challenge in modern medicine. Displaced fractures in childhood are often treated by osteosynthesis, which requires a second surgical procedure to remove fixation implants, thereby increasing operative risks. Biodegradable magnesium-based screws represent a promising solution, as they resorb in vivo and, according to available data, exhibit osteoinductive properties. AIM: To determine and evaluate the optimal biocompatibility, corrosion resistance, and reparative properties of bioresorbable Mg-Ca-Zn alloy screws in vivo and in vitro using an experimental intra-articular fracture model. METHODS: To assess reparative, bioresorptive, and biocompatible properties, bioresorbable headless cannulated compression screws with different coating thicknesses (15, 25, 35, 45, and 55 μm), a cylindrical thread diameter of 3.5 mm, and a length of 20.0 mm were implanted into the posteromedial surface of the proximal third of the tibia in Soviet Chinchilla rabbits. Animals were euthanized 2 months after experiment, followed by instrumental and histological examinations. Implant biodegradation was assessed in vivo by the presence of gas formation in bone tissue, whereas biocompatibility and the reparative bone response were evaluated based on peri-implant bone density and histological findings. RESULTS: All coated Mg–Ca–Zn screw samples demonstrated optimal biocompatibility and a favorable reparative bone response. CONCLUSION: Experimental in vivo evaluation of Mg-Ca-Zn bioresorbable screws in bone tissue showed that the implants undergo biodegradation and exhibit good biocompatibility and reparative response, indicating their fundamental feasibility for use in traumatology practice.